Lifebreath METRO 120F-ECM HRV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: METRO 120F-ECM
110 cfm net1,200 to 2,000 sq ftHRV
Talk to an HVAC technician · 514 316-2973
Lifetime core warranty
01 · Your home

Is it the right size for your home?

It delivers 110 cfm net, enough to ventilate 1,200 to 2,000 sq ft. Choose your home's living area.

It's the right size.

For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 110 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.

02 · Performance

What it does, in numbers

Heat recovery
71%
At 0 °CCertified at 49 cfm
Net airflowThe ducts cost it 13 cfm
0.2 in · test bench123 cfm
0.4 in · with ducts110 cfm

$17.57

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

18W
Running continuously
158kWh
Per year
3months
Filter cleaning

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 18 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

ECMHigh-efficiency ECM blowers, unlike the 120F

The METRO 120F sheet describes independent centrifugal blowers; the 120F-ECM sheet specifies a high-efficiency ECM blower with multiple speeds on each airstream. The cabinet stays 9.75 in high.

AB / FIDOffered in -AB and -FID versions

Lifebreath offers hardwired, auto-balance (METRO 120F-ECM-AB) and fault indicator display (METRO 120F-ECM-FID) configurations. Only the FID version, Title 24 compliant, displays error codes for certain faults.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.

2505200Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−13 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 123 to 110 cfm. Most spec sheets show only the first number, precisely because it looks better.

18 WMeasured at the airflow it actually runs at

Its 71% at 0 °C is certified at 49 cfm, the continuous airflow of a typical home. At that setting it draws 18 W, or about 158 kWh a year.

LifetimeThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years.

5 inWhat it needs on site

5 in ducts, side connection and a condensate drain. It weighs 34 lb, and it needs enough clearance to slide the core out for cleaning.

04 · Installation

What it needs on site

5 in ductsCollar diameter
Side connectionSide ports
Condensate drainRequired
34 lbUnit weight
20.75 × 20.19 × 9.75 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
123 cfm
Net airflow at 0.4 in. w.g.
110 cfm
SRE at 0 °C (49 cfm)
71%
ASE at 0 °C
74%
Power draw
18 W
Efficacy
2.7 cfm/W
Type
HRV
Connection
Side ports
Duct collars
5 in
Condensate drain
Required
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
Dimensions (L × D × H)
20.75 × 20.19 × 9.75 in
Weight
34 lb
Power supply
120 V
HVI certification (Section III)
2505200
Warranty — core
Lifetime
Warranty — motors
5 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505200). The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up. Annual consumption calculated at 18 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

The METRO 120F with ECM motors: 18 W at the test point

The Lifebreath METRO 120F-ECM keeps the short cabinet of the METRO 120F, but each of its two airstreams is driven by a centrifugal blower with a high-efficiency, multi-speed ECM motor. This heat recovery ventilator (HRV) stands no more than 9.75 in. high, not counting the drain cup (1 in.).

At 0.2 in. of static pressure, its net airflow is 123 cfm; at 0.4 in., 110 cfm, or 21 cfm less than the METRO 120F at the same point.

What the ECM Motor Changes

HVI measures 18 W at 49 cfm, or 2.7 cfm per watt, where the METRO 120F needs 59 at 47 cfm. A unit running like this continuously all year uses about 158 kWh, which works out to some $18 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh). Since an air exchanger runs nonstop most of the time, that gap comes back every year.

Lifebreath gives the unit an operating range of 50 to 130 cfm. High speed is selected on the circuit board's DIP switches, and we set it to the airflow established by the assessment of your home, not to maximum speed.

Efficiency

At 0°C and 49 cfm, the counter-flow aluminum HEX core reaches 71% sensible recovery efficiency according to HVI. That directory, however, gives no rating at −25°C for the METRO 120F-ECM, and its spec sheet publishes none. Art. 9.36.3.9 of the Québec Construction Code assesses efficiency precisely at −25°C and at no less than 22 L/s: a minimum of 55% where there are fewer than 6,000 heating degree-days, 60% elsewhere. Without that rating, the unit cannot show compliance where the article applies; in that case, we steer you toward a Lifebreath model rated at −25°C.

To defrost, the unit shuts off its fresh air supply and warm stale air flows through the core at high speed. This cycle starts when the outdoor temperature drops below −3°C.

AB and FID Versions

Lifebreath offers this unit in a hardwired configuration, in an auto-balance version (METRO 120F-ECM-AB) and in a fault indicator display version (METRO 120F-ECM-FID). The AB version continuously adjusts its motor speed to hold the set airflow, which it measures by differential pressure; its auto-balancing must be done with the 99-DXPL03 control. The FID version, which Lifebreath offers for California Title 24 compliance, displays fault codes: Err 3 or Err 4, for example, signal that the unit is not reaching the requested supply or exhaust airflow. If either version interests you, let us know when you ask for your quote.

Installation

At 34 lb, the cabinet covers an area of 20 3/4 in. by 20 3/16 in. It hangs from the ceiling on the brackets supplied. Round 5 in. (125 mm) collars take its four ducts. The multi-position drain is required, and for service, Lifebreath advises leaving 25 in. (635 mm) clear in front of the unit.

The hinged door needs no screws, and the motor and electronics assembly comes out in one piece. On this ECM model, the 99-BC04 basic control cannot be used, according to the METRO manual; the 99-DXPL03, on the other hand, works. The main control goes on a wall, in the middle of the home.

Filters

Each airstream passes through a washable MERV 6 filter, on the stale-air side as on the fresh-air side; part 65-195-6R allows an upgrade to MERV 13. According to its spec sheet, the core is easily removed for cleaning.

Warranty

Core warranted for life by Lifebreath, motors and parts warranted for 5 years.

Which Home It Suits

Lifebreath designed the METRO 120F-ECM for townhomes, high-rise condos and apartments where mechanical space is tight. It is mainly for the owner who wants continuous ventilation without watching the electricity bill climb, in a home where 110 cfm net is enough.

Installation by AirGreen in Greater Montreal

Before any recommendation, we assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement) and check that the METRO 120F-ECM's 110 cfm net at 0.4 in. covers them with the planned duct length.

The unit must be in a heated space; if it is placed above an area that water could damage, Lifebreath recommends adding an auxiliary drain pan. The standard version is among the units Lifebreath describes as factory balanced, provided the supply and exhaust static pressures are no more than 0.3 in. apart; we check this at start-up. The AB and FID versions are balanced instead with the collar port method described in the METRO manual.

Going forward, the METRO manual calls for inspecting the outdoor hoods at least once a month, cleaning the drain line twice a year and the ducts once a year. The motors need no maintenance, but their impellers should be cleaned when dirty.

Our team, under AirGreen's RBQ licence 5645-9605-01, installs the METRO 120F-ECM in Montreal, Laval, Longueuil, the North Shore and the South Shore.

Since October 1, 2026, Rénoclimat no longer funds HRV or ERV installations, except for a home already evaluated before the change whose post-work evaluation is done by March 31, 2027.

Ask for your free quote: 514 316-2973 or sales@airgreen.ca. We will call you back to go over your project.