Is it the right size for your home?

It delivers 110 cfm net, enough to ventilate 1,200 to 2,000 sq ft. Choose your home's living area.

It's the right size.

For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 110 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
71%
At 0 °CCertified at 49 cfm
Net airflowThe ducts cost it 13 cfm
0.2 in · test bench123 cfm
0.4 in · with ducts110 cfm

$17.57

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

18W
Running continuously
158kWh
Per year
3months
Filter cleaning

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 18 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

ECMHigh-efficiency ECM blowers, unlike the 120F

The METRO 120F sheet describes independent centrifugal blowers; the 120F-ECM sheet specifies a high-efficiency ECM blower with multiple speeds on each airstream. The cabinet stays 9.75 in high.

AB / FIDOffered in -AB and -FID versions

Lifebreath offers hardwired, auto-balance (METRO 120F-ECM-AB) and fault indicator display (METRO 120F-ECM-FID) configurations. Only the FID version, Title 24 compliant, displays error codes for certain faults.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, the problem is almost always too much humidity, not too little.

2505200Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.

−13 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 123 to 110 cfm. Most spec sheets show only the first number, precisely because it looks better.

18 WMeasured at the airflow it actually runs at

Its 71% at 0 °C is certified at 49 cfm, the continuous airflow of a typical home. At that setting it draws 18 W, or about 158 kWh a year.

LifetimeThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years. We register the warranty in your name at commissioning.

5 inWhat it needs on site

5 in ducts, side connection and a condensate drain. It weighs 34 lb, and it needs enough clearance to slide the core out once a year.

Grant

Rénoclimat: $500 to install or replace an HRV or ERV

First condition met: HVI Section III certified, No. 2505200. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.

$500
04 · Installation

What it needs on site

5 in ductsCollar diameter
Side connectionSide ports
Condensate drainRequired
34 lbUnit weight
20.75 × 20.19 × 9.75 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
123 cfm
Net airflow at 0.4 in. w.g.
110 cfm
SRE at 0 °C (49 cfm)
71%
ASE at 0 °C
74%
Power draw
18 W
Efficacy
2.7 cfm/W
Type
HRV
Connection
Side ports
Duct collars
5 in
Condensate drain
Required
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
Dimensions (L × D × H)
20.75 × 20.19 × 9.75 in
Weight
34 lb
Power supply
120 V
HVI certification (Section III)
2505200
Warranty — core
Lifetime
Warranty — motors
5 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505200). The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up. Annual consumption calculated at 18 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Le METRO 120F avec des moteurs ECM : 18 W au point d'essai

Le Lifebreath METRO 120F-ECM reprend le boîtier bas du METRO 120F, mais remplace ses soufflantes par des soufflantes centrifuges à moteur ECM haute efficacité, une par flux d'air. C'est un ventilateur récupérateur de chaleur (VRC) de 9,75 po de hauteur, conçu pour les condos, les appartements et les maisons de ville où l'espace mécanique est limité.

Son débit net atteint 110 pcm à 0,4 po de pression statique et 123 pcm à 0,2 po. C'est un peu moins que le 120F, mais avec une fraction de la consommation électrique.

Ce que change le moteur ECM

Au point d'essai HVI de 49 pcm, l'appareil consomme 18 W, soit 2,7 pcm par watt. En marche continue à ce régime, cela représente environ 158 kWh par année, autour de 18 $ d'électricité. Un échangeur d'air tourne souvent jour et nuit; sur dix ou quinze ans, l'écart de consommation compte.

Lifebreath annonce une plage de 50 à 130 pcm et trois sélections de haute vitesse par commutateurs DIP (Hi 3 en usine). Nous réglons l'appareil sur le débit calculé, pas sur la vitesse maximale.

Efficacité

Le noyau en aluminium à contre-courant donne une efficacité de récupération sensible de 71 % à 0 °C et 49 pcm. Lifebreath ne publie pas de cote HVI à −25 °C pour ce modèle; nous en tenons compte pour un logement très exposé au froid.

Le dégivrage se fait par ventilateur : l'arrivée d'air frais s'arrête et l'air vicié chaud passe à haute vitesse dans le noyau.

Versions AB et FID

Lifebreath propose le METRO 120F-ECM en configuration à câblage permanent, en version à équilibrage automatique (METRO 120F-ECM-AB) et en version à affichage des codes de défaut (METRO 120F-ECM-FID). Seule la version FID, conforme à la norme Title 24, affiche des codes d'erreur pour certaines pannes qui nuisent au fonctionnement. Si l'une de ces versions vous intéresse, dites-le-nous à la soumission, car elles ont chacune leur fiche.

Installation

Le boîtier mesure 20,75 × 20,19 × 9,75 po (L × P × H) et pèse 34 lb. Des supports de fixation au plafond sont fournis. Les conduits se raccordent à des collets ronds de 5 po sur les côtés (raccordement latéral). Un drain est requis, avec un drain multiposition. Prévoyez 25 po de dégagement devant la porte.

La porte à charnières s'ouvre sans vis et le moteur et l'électronique se retirent d'un bloc. La commande principale se fixe au mur dans un endroit central.

Filtres

Deux filtres lavables MERV 6, un sur l'air vicié et un sur l'air frais. Une mise à niveau MERV 13 est offerte (pièce 65-195-6R). Le noyau se retire pour le nettoyage.

Garantie

Noyau garanti à vie par Lifebreath, moteurs et pièces garantis 5 ans.

Pour quel logement

Le METRO 120F-ECM vise le propriétaire de condo qui veut une ventilation continue sans voir sa facture d'électricité grimper. Il garde la hauteur de 9,75 po de la famille METRO et ajoute la sobriété des moteurs ECM. Si votre immeuble exige un suivi des pannes ou un équilibrage automatique, nous regardons avec vous les versions AB et FID. Pour une maison avec salle mécanique au sous-sol, un appareil à raccords sur le dessus est souvent plus pratique.

Installation par AirGreen dans le Grand Montréal

Le bon échangeur d'air est celui qui livre le débit dont votre maison a besoin, ni plus ni moins. Nous partons donc d'un calcul pièce par pièce selon la norme CSA F326, et nous vérifions que le METRO 120F-ECM, avec ses 110 pcm nets à 0,4 po, couvre ce besoin avec la longueur de conduits prévue. Avec un débit net de cet ordre, il vise surtout les condos et les petites maisons de ville.

Nous installons l'appareil, nous raccordons les conduits et la commande, puis nous équilibrons les deux flux d'air au débit calculé. Nous vous montrons ensuite comment utiliser la commande et nettoyer les filtres. Les conduits qui traversent une zone non chauffée sont isolés, pour éviter la condensation.

AirGreen dessert Montréal, Laval, Longueuil, la Rive-Nord et la Rive-Sud.

Le METRO 120F-ECM est admissible à l'aide Rénoclimat de 500 $ si l'appareil est homologué à la section III du répertoire HVI (c'est le cas du METRO 120F-ECM, numéro HVI 2505200) et si la cote ÉnerGuide s'améliore entre les deux évaluations; l'évaluation doit être faite avant le début des travaux.

Demandez votre soumission gratuite : 514 316-2973 ou sales@airgreen.ca. Nous vous rappelons pour préciser votre projet.