Lifebreath RNC5-HEX-TPF HRV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 89 cfm net, enough to ventilate 1,000 to 1,600 sq ft. Choose your home's living area.
It's the right size.
For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 89 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$30.26
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Code's 55% threshold; below the 60% it requires where there are 6,000 degree-days or more. At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 57% at 70 cfm (HVI).
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 31 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
HEXPatented HEX core in the RNC5 series
Lifebreath presents it as an RNC5 fitted with the patented counter-flow HEX core for higher efficiency. At 0 °C and 95 cfm its sheet lists 73%, versus 62% for the cross-flow-core RNC5-TPF.
33.6 inLonger cabinet than the RNC5-TPF
The HEX core sits in a 33.6 × 15.1 × 18.7 in cabinet, while the RNC5-TPF measures 22.75 × 14 × 17.25 in. Allow 25 in of clearance in front of the door as well.
57%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 70 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.
2505492Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−17 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 106 to 89 cfm. Most spec sheets show only the first number, precisely because it looks better.
31 WMeasured at the airflow it actually runs at
Its 75% at 0 °C is certified at 64 cfm, the continuous airflow of a typical home. At that setting it draws 31 W, or about 272 kWh a year.
LifetimeThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
5 inWhat it needs on site
5 in (oval) ducts, top connection and a condensate drain. It weighs 57 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 106 cfm
- Net airflow at 0.4 in. w.g.
- 89 cfm
- SRE at 0 °C (64 cfm)
- 75%
- SRE at −25 °C (70 cfm)
- 57%
- ASE at 0 °C
- 78%
- Power draw
- 31 W
- Efficacy
- 2.1 cfm/W
- Type
- HRV
- Connection
- Top ports
- Duct collars
- 5 in (oval)
- Condensate drain
- Required
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
- Dimensions (L × D × H)
- 33.6 × 15.1 × 18.7 in
- Weight
- 57 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505492
- Warranty — core
- Lifetime
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505492). Annual consumption calculated at 31 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
An RNC5 with a HEX core: more efficiency, 31 W of power draw
Take an RNC5, swap its cross-flow core for the patented counter-flow HEX core, and you get the Lifebreath RNC5-HEX-TPF, a low-consumption heat recovery ventilator (HRV). Lifebreath presents it as a more efficient unit that keeps all the features of the RNC5 series.
According to Lifebreath's spec sheet, its net airflow goes from 114 cfm at 0.1 in. of static pressure to 106 cfm at 0.2 in. and 89 cfm at 0.4 in., the value HVI also lists. It then drops quickly: 66 cfm at 0.6 in., 34 cfm at 0.8 in. A short, direct duct run therefore lets it deliver its full airflow.
What the HEX core changes
In this core, the fresh air and the stale air move in opposite directions, and the heat of one passes to the other. At 0 °C, HVI gives the RNC5-HEX-TPF a sensible recovery efficiency of 75% at 64 cfm, and 73% at 95 cfm. At the same 95 cfm, the RNC5-TPF and its cross-flow core stop at 62%. At −25 °C and 70 cfm, its sensible recovery efficiency is 57% (HVI directory, November 4, 2026 edition). The Québec Construction Code (art. 9.36.3.9) requires at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at a minimum of 22 L/s. At 57%, it reaches the 55% threshold, not the 60% one. Lifebreath designed the core to slide out of the unit easily when it is time to clean it.
Low energy use
One motorized impeller per airstream, adjustable over several speeds, moves the air. HVI measures 31 W at 64 cfm, or 2.1 cfm per watt, and 46 W at 95 cfm. At −25 °C, at the 70 cfm test airflow, its draw even dips to 30 W. Among the Lifebreath HRVs we offer, only three draw less at their first HVI test point: the METRO 120F-ECM (18 W), then the METRO 120D-ECM and the 267 MAX (22 W each). Running continuously all year at 31 W, the RNC5-HEX-TPF uses about 272 kWh, around $30 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh).
Fan defrost
Defrost is triggered by a temperature sensor: the fresh-air motor stops at intervals, and the house air, which keeps flowing out, defrosts the core. The RNC6-HEX-TPD, which has the same HEX core, defrosts instead with a recirculating damper; HVI gives it 65% at −25 °C (at 66 cfm), but it draws 65 W at 64 cfm, more than double.
A longer cabinet
The HEX core sits in a cabinet 33.6 in. long, 18.7 in. high and 15.1 in. deep, while the RNC5-TPF fits in 22.75 × 14 × 17.25 in. The unit weighs 57 lb. Before choosing this model, we therefore measure the free length in the basement or mechanical room, keeping the 25 in. that Lifebreath recommends in front of the door.
Connections and balancing
The four ducts come in from the top, onto 5 in. oval collars that each have their own balancing damper; airflow is measured through the ports on the door. The high speed is set with DIP switches, and the unit leaves the factory at Hi 3. Four threaded inserts take the “S” hooks and hanging straps supplied in the box. The drain is required, on two 1/2 in. (12 mm) fittings. The wall control, available as an option, needs three-wire cable of at least 20 gauge, and the distance to the unit must not exceed 100 ft.
Filters
The core is protected by two washable MERV 6 filters, one for the stale air and one for the fresh air. For finer filtration, Lifebreath offers MERV 13 under part number 65-195-6R.
Warranty
Core warranted for life by Lifebreath; motors and parts warranted for 5 years.
Which home it suits
The RNC5-HEX-TPF suits a small house, a bungalow, a semi-detached house or a townhouse that has room in the basement and whose needs fit within its 89 cfm net at 0.4 in. For a home that ventilates continuously, its low draw shows on the electricity bill from one year to the next. If the house is very exposed to the cold, we compare it with the RNC6-HEX-TPD before choosing.
Installation by AirGreen in Greater Montreal
First, we assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement). If the result is well above 89 cfm net, we steer you toward a higher-airflow model.
With an airflow of this size, a single 6 in. opening in the outside wall can be enough: the Lifebreath 99-190 dual hood, made for 5 or 6 in. ducts, serves as both the fresh-air intake and the stale-air outlet up to 140 cfm. Lifebreath then calls for insulating both ducts back to the unit and for having the local building authority confirm first that the hood complies. Inside, the kitchen exhaust grilles stay at least 4 ft (1.2 m) horizontally from the stove, so that grease does not get into the unit, and they are never connected to the range hood. Grilles go high on the walls or in the ceiling. On start-up day, we balance the two airflows with the collar dampers, the unit on high speed and the range hood, dryer and bathroom fans off.
Our team, under AirGreen's RBQ licence 5645-9605-01, installs the RNC5-HEX-TPF in Montreal, Laval, Longueuil, the North Shore and the South Shore.
Since October 1, 2026, Rénoclimat no longer funds HRV or ERV installations, except for a home already evaluated before the change whose post-work evaluation is done by March 31, 2027.
For a free quote, reach us at 514 316-2973 or write to us at sales@airgreen.ca.