Lifebreath RNC 88 HRV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 85 cfm net, enough to ventilate 1,000 to 1,600 sq ft. Choose your home's living area.
It's the right size.
For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 85 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$36.11
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Code's 55% threshold; below the 60% it requires where there are 6,000 degree-days or more. At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 57% at 57 cfm (HVI).
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 37 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
4 in4 in round collars on top
All RNC 88 connections are 4 in round collars located on top of the unit. Lifebreath aims it at homes with tight space requirements.
HooksHangs from supplied S hooks and straps
Four threaded inserts at the corners of the 36 lb cabinet take the “S” hooks and hanging straps supplied with the unit. The balancing ports are on the door.
57%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 57 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.
2505479Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−12 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 97 to 85 cfm. Most spec sheets show only the first number, precisely because it looks better.
37 WMeasured at the airflow it actually runs at
Its 60% at 0 °C is certified at 64 cfm, the continuous airflow of a typical home. At that setting it draws 37 W, or about 324 kWh a year.
LifetimeThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
4 inWhat it needs on site
4 in ducts, top connection and a condensate drain. It weighs 36 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 97 cfm
- Net airflow at 0.4 in. w.g.
- 85 cfm
- SRE at 0 °C (64 cfm)
- 60%
- SRE at −25 °C (57 cfm)
- 57%
- ASE at 0 °C
- 63%
- Power draw
- 37 W
- Efficacy
- 1.7 cfm/W
- Type
- HRV
- Connection
- Top ports
- Duct collars
- 4 in
- Condensate drain
- Required
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
- Dimensions (L × D × H)
- 18.25 × 18.13 × 17 in
- Weight
- 36 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505479
- Warranty — core
- Lifetime
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505479). Annual consumption calculated at 37 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
A 4 in. collar HRV for tight spaces
Lifebreath aims the RNC 88, a heat recovery ventilator (HRV) it presents as very compact, at homes where space is tight. All of its connections are 4 in. (102 mm) round collars, located on top of the unit.
On airflow, it delivers 85 cfm net at 0.4 in. of static pressure; at 0.2 in., it rises to 97 cfm.
Light and easy to hang
The unit weighs 36 lb (16.3 kg), and no dimension on Lifebreath's drawing exceeds 20 1/4 in. (514 mm). It hangs from the “S” hooks and straps supplied with it, fastened into four threaded inserts at the corners of the cabinet. The cabinet, made of 22-gauge prepainted galvanized steel, is insulated so that condensation does not form on its outer walls. In front of the door, Lifebreath recommends 25 in. (635 mm) of clearance for service.
Efficiency
The cross-flow core warms the fresh air with heat from the stale air; it comes out for cleaning or service. HVI rates its sensible recovery efficiency at 60% at 0 °C and 64 cfm. At −25 °C and 57 cfm, its sensible recovery efficiency is 57% (HVI directory, November 4, 2026 edition); the Québec Construction Code (art. 9.36.3.9) requires at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at no less than 22 L/s. The RNC 88 therefore clears the first threshold, but not the second.
The RNC4-TPD, the other 4 in. collar HRV in our lineup, makes the opposite trade-off. It keeps 65% efficiency at −25 °C, but delivers 26 cfm less than the RNC 88 at 0.4 in. (59 versus 85, HVI directory). At their first HVI test point, both units draw 37 W. So the RNC 88 favours airflow, and the RNC4-TPD favours cold-weather performance.
Energy use
Each of the two airstreams is driven by its own motorized impeller with several speeds. At 64 cfm, its 0 °C test point, HVI measures 37 W, or 1.7 cfm per watt. Run continuously at that setting, it uses about 324 kWh a year, or around $36 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh).
Fan defrost
In deep cold, a temperature sensor triggers defrost: the fresh-air motor shuts off periodically, while the stale house air keeps flowing through the core and melts the frost.
Balancing and drain
The balancing ports are on the door. High speed is set with DIP switches on the circuit board; Lifebreath ships the unit at Hi 3 (speed 5). A drain is required: the unit has two 12 mm (1/2 in.) OD spouts. The wall control is optional; Lifebreath advises mounting it in a central spot in the home.
Filters
The stale air and the fresh air each go through a washable MERV 6 filter. Lifebreath part 65-195-6R upgrades them to MERV 13 filters.
Warranty
Lifebreath warrants the core for life, and the motors and parts for 5 years.
Which home it suits
With 85 cfm net at 0.4 in. and 4 in. collars, the RNC 88 is aimed at renovations where room is short: a duplex or triplex converted into a single-family home, a basement apartment, a townhouse. In these buildings, the ducts often have to run through existing walls or between already crowded joists, and a 4 in. duct needs smaller openings than a 5 or 6 in. duct. If the home's needs exceed that airflow, we will suggest a model with 5 or 6 in. collars.
Installation by AirGreen in Greater Montreal
Before recommending the RNC 88, we assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement) and work out where its 4 in. ducts will run. This air exchanger goes in a heated space with clear access for service; Lifebreath does not recommend the attic. We hang it level, as Lifebreath requires so that condensation drains properly.
For the drain, Lifebreath asks on this model that an O-ring be slipped onto the spout before it goes through the drain pan hole. We then build a P-trap with the plastic tee; the trap and tubing stay below the bottom of the door, sloping down 1/4 in. per foot from the unit, and we prime the trap by pouring a cup of water into the drain pan. The unit and its condensate tubing must stay in a space protected from freezing.
At start-up, the unit runs on high speed during balancing: readings taken at the door ports, checked against the RNC 88 airflow charts in Lifebreath's guide, show which airflow is stronger, and we turn it down until it matches the other.
AirGreen serves Montreal, Laval, Longueuil, the North Shore and the South Shore.
Since October 1, 2026, Rénoclimat no longer funds HRV or ERV installations, except for a home already evaluated before the change whose post-work evaluation is done by March 31, 2027.
For a free quote, call us at 514 316-2973 or send your plans to sales@airgreen.ca.