Lifebreath METRO 120F HRV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 131 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 131 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$57.59
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 59 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
20.75 inCabinet 20.75 in wide and 9.75 in high
The cabinet is 20.75 in wide, 19.38 in deep and 9.75 in high, plus 1 in for the drain cup. Brackets are supplied for ceiling installation.
DoorHinged door with no screws, swing-open e-box
The hinged door opens without screws and the e-box cover swings open for access to the circuit board and DIP switches. The motor and electronics come out as one assembly for service.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.
2505111Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−11 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 142 to 131 cfm. Most spec sheets show only the first number, precisely because it looks better.
59 WMeasured at the airflow it actually runs at
Its 71% at 0 °C is certified at 47 cfm, the continuous airflow of a typical home. At that setting it draws 59 W, or about 517 kWh a year.
LifetimeThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection and a condensate drain. It weighs 34 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 142 cfm
- Net airflow at 0.4 in. w.g.
- 131 cfm
- SRE at 0 °C (47 cfm)
- 71%
- ASE at 0 °C
- 80%
- Power draw
- 59 W
- Efficacy
- 0.8 cfm/W
- Type
- HRV
- Connection
- Side ports
- Duct collars
- 5 in
- Condensate drain
- Required
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
- Dimensions (L × D × H)
- 20.75 × 19.38 × 9.75 in
- Weight
- 34 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505111
- Warranty — core
- Lifetime
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505111). The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up. Annual consumption calculated at 59 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
A short-format METRO 120: 34 lb and 9.75 in. high
The Lifebreath METRO 120F is a heat recovery ventilator (HRV) with a short cabinet: 20.75 in. by 19.38 in., at 9.75 in. high, plus 1 in. for the drain cup, and 34 lb on the scale. It shares this 20.75 in. width with the METRO 120F-ECM and the METRO 120 ERV.
At 0.2 in. of static pressure, it pushes 142 cfm net; at 0.4 in., 131 remain. It defrosts with its fan, where the METRO 120D uses a damper. Its two independent, multi-speed centrifugal blowers have no ECM motor.
A Cabinet Designed for the Technician
No screws hold the hinged door. Once the swing-open e-box cover is open, the circuit board and its DIP switches are within easy reach, and the motor and electronics assembly comes out whole, which simplifies a repair in a ceiling where you work with your arms raised. Brackets come with the unit for ceiling mounting.
According to Lifebreath, the unit operates between 50 and 130 cfm. Its high speed is set on the DIP switches, and we adjust it to the airflow that comes out of the assessment of your home.
Efficiency and Energy Use
Its aluminum HEX core works on the counter-flow principle. HVI rates it at three airflows, all at 0°C: 71% sensible recovery efficiency at 47 cfm for 59 W, 69% at 64 cfm for 62 W, and 65% at 97 cfm for 98 W. The faster air moves through the core, the less time it has to leave its heat behind.
At 59 W running continuously, at the 47 cfm test point (0.8 cfm per watt), the METRO 120F uses about 517 kWh a year, or around $58 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh). For comparison, HVI measures 18 W at 49 cfm on the METRO 120F-ECM, its ECM-motor version.
HVI gives it no rating at −25°C, and Lifebreath's spec sheet does not give one either. Yet art. 9.36.3.9 of the Québec Construction Code assesses efficiency at that temperature: at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at no less than 22 L/s. Where that article applies, the METRO 120F therefore cannot show compliance, and we offer you a Lifebreath model rated at −25°C.
Fan Defrost
Below −3°C outside, the unit shuts off its supply air in cycles, and the warm stale air, pushed at high speed, defrosts the core. At −20°C, the METRO manual provides for 4.5 minutes of defrost per 17 minutes of ventilation.
Installation and Connections
Its four 5 in. (125 mm) round collars take the ducts. The drain is mandatory and multi-position. At the front, Lifebreath recommends keeping 25 in. (635 mm) clear for service. The main control mounts on a wall in a central spot in the home, and Lifebreath also offers a hardwired configuration. Unlike the ECM versions in the series, the METRO 120F accepts the 99-BC04 basic control, in addition to the 99-DXPL03, which runs every METRO.
Filters and Maintenance
The stale air and the fresh air each have their own washable MERV 6 filter; part 65-195-6R upgrades them to MERV 13. According to the spec sheet, the core comes out easily when it is time to clean or service it.
Warranty
The core is warranted for life by Lifebreath; motors and parts, 5 years.
Which Home It Suits
The METRO 120F is aimed, according to Lifebreath, at high-rise condos, townhomes and apartments with limited mechanical space. With 131 cfm net at 0.4 in. and a 34 lb cabinet, it fits in a bulkhead, in a closet or above a stacked washer and dryer, locations the METRO manual names itself.
Installation by AirGreen in Greater Montreal
Before recommending the METRO 120F, we assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement), then compare the total with its 131 cfm net. A unit too weak or too strong for the home will not do: we tell you so plainly, with another model to back it up. In a condo, it is often the duct route to the outside wall that decides between the METRO 120F and another version.
Between the unit and the outdoor hoods, Lifebreath calls for insulated flexible duct pulled taut and kept as short as possible, and sealed, insulated rigid duct once the run exceeds 10 ft (3.3 m). If there are prevailing winds, the fresh-air intake goes on the side they come from, ahead of the stale-air outlet, as its manual specifies. The unit stays in a heated space, and its drain line above the freezing point.
The METRO 120F is among the units Lifebreath describes as factory balanced: when the static pressure of the supply duct system and that of the exhaust duct system differ by 0.3 in. or less, its airflows stay within 10% of each other. We therefore take both readings at start-up.
Our team, under AirGreen's RBQ licence 5645-9605-01, installs the METRO 120F in Montreal, Laval, Longueuil, the South Shore and the North Shore.
Since October 1, 2026, Rénoclimat no longer funds HRV or ERV installations, except for a home already evaluated before the change whose post-work evaluation is done by March 31, 2027.
For an installed price, ask for a free quote at 514 316-2973 or sales@airgreen.ca: we will call you back.