Lifebreath METRO 120F HRV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: METRO 120F
131 cfm net1,500 to 2,400 sq ftHRV
Talk to an HVAC technician · 514 316-2973
Lifetime core warranty
01 · Your home

Is it the right size for your home?

It delivers 131 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 131 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.

02 · Performance

What it does, in numbers

Heat recovery
71%
At 0 °CCertified at 47 cfm
Net airflowThe ducts cost it 11 cfm
0.2 in · test bench142 cfm
0.4 in · with ducts131 cfm

$57.59

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

59W
Running continuously
517kWh
Per year
3months
Filter cleaning

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 59 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

20.75 inCabinet 20.75 in wide and 9.75 in high

The cabinet is 20.75 in wide, 19.38 in deep and 9.75 in high, plus 1 in for the drain cup. Brackets are supplied for ceiling installation.

DoorHinged door with no screws, swing-open e-box

The hinged door opens without screws and the e-box cover swings open for access to the circuit board and DIP switches. The motor and electronics come out as one assembly for service.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.

2505111Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−11 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 142 to 131 cfm. Most spec sheets show only the first number, precisely because it looks better.

59 WMeasured at the airflow it actually runs at

Its 71% at 0 °C is certified at 47 cfm, the continuous airflow of a typical home. At that setting it draws 59 W, or about 517 kWh a year.

LifetimeThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years.

5 inWhat it needs on site

5 in ducts, side connection and a condensate drain. It weighs 34 lb, and it needs enough clearance to slide the core out for cleaning.

04 · Installation

What it needs on site

5 in ductsCollar diameter
Side connectionSide ports
Condensate drainRequired
34 lbUnit weight
20.75 × 19.38 × 9.75 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
142 cfm
Net airflow at 0.4 in. w.g.
131 cfm
SRE at 0 °C (47 cfm)
71%
ASE at 0 °C
80%
Power draw
59 W
Efficacy
0.8 cfm/W
Type
HRV
Connection
Side ports
Duct collars
5 in
Condensate drain
Required
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
Dimensions (L × D × H)
20.75 × 19.38 × 9.75 in
Weight
34 lb
Power supply
120 V
HVI certification (Section III)
2505111
Warranty — core
Lifetime
Warranty — motors
5 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505111). The manufacturer doesn't publish an efficiency at −25 °C for this model; we don't make one up. Annual consumption calculated at 59 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

A short-format METRO 120: 34 lb and 9.75 in. high

The Lifebreath METRO 120F is a heat recovery ventilator (HRV) with a short cabinet: 20.75 in. by 19.38 in., at 9.75 in. high, plus 1 in. for the drain cup, and 34 lb on the scale. It shares this 20.75 in. width with the METRO 120F-ECM and the METRO 120 ERV.

At 0.2 in. of static pressure, it pushes 142 cfm net; at 0.4 in., 131 remain. It defrosts with its fan, where the METRO 120D uses a damper. Its two independent, multi-speed centrifugal blowers have no ECM motor.

A Cabinet Designed for the Technician

No screws hold the hinged door. Once the swing-open e-box cover is open, the circuit board and its DIP switches are within easy reach, and the motor and electronics assembly comes out whole, which simplifies a repair in a ceiling where you work with your arms raised. Brackets come with the unit for ceiling mounting.

According to Lifebreath, the unit operates between 50 and 130 cfm. Its high speed is set on the DIP switches, and we adjust it to the airflow that comes out of the assessment of your home.

Efficiency and Energy Use

Its aluminum HEX core works on the counter-flow principle. HVI rates it at three airflows, all at 0°C: 71% sensible recovery efficiency at 47 cfm for 59 W, 69% at 64 cfm for 62 W, and 65% at 97 cfm for 98 W. The faster air moves through the core, the less time it has to leave its heat behind.

At 59 W running continuously, at the 47 cfm test point (0.8 cfm per watt), the METRO 120F uses about 517 kWh a year, or around $58 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh). For comparison, HVI measures 18 W at 49 cfm on the METRO 120F-ECM, its ECM-motor version.

HVI gives it no rating at −25°C, and Lifebreath's spec sheet does not give one either. Yet art. 9.36.3.9 of the Québec Construction Code assesses efficiency at that temperature: at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at no less than 22 L/s. Where that article applies, the METRO 120F therefore cannot show compliance, and we offer you a Lifebreath model rated at −25°C.

Fan Defrost

Below −3°C outside, the unit shuts off its supply air in cycles, and the warm stale air, pushed at high speed, defrosts the core. At −20°C, the METRO manual provides for 4.5 minutes of defrost per 17 minutes of ventilation.

Installation and Connections

Its four 5 in. (125 mm) round collars take the ducts. The drain is mandatory and multi-position. At the front, Lifebreath recommends keeping 25 in. (635 mm) clear for service. The main control mounts on a wall in a central spot in the home, and Lifebreath also offers a hardwired configuration. Unlike the ECM versions in the series, the METRO 120F accepts the 99-BC04 basic control, in addition to the 99-DXPL03, which runs every METRO.

Filters and Maintenance

The stale air and the fresh air each have their own washable MERV 6 filter; part 65-195-6R upgrades them to MERV 13. According to the spec sheet, the core comes out easily when it is time to clean or service it.

Warranty

The core is warranted for life by Lifebreath; motors and parts, 5 years.

Which Home It Suits

The METRO 120F is aimed, according to Lifebreath, at high-rise condos, townhomes and apartments with limited mechanical space. With 131 cfm net at 0.4 in. and a 34 lb cabinet, it fits in a bulkhead, in a closet or above a stacked washer and dryer, locations the METRO manual names itself.

Installation by AirGreen in Greater Montreal

Before recommending the METRO 120F, we assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement), then compare the total with its 131 cfm net. A unit too weak or too strong for the home will not do: we tell you so plainly, with another model to back it up. In a condo, it is often the duct route to the outside wall that decides between the METRO 120F and another version.

Between the unit and the outdoor hoods, Lifebreath calls for insulated flexible duct pulled taut and kept as short as possible, and sealed, insulated rigid duct once the run exceeds 10 ft (3.3 m). If there are prevailing winds, the fresh-air intake goes on the side they come from, ahead of the stale-air outlet, as its manual specifies. The unit stays in a heated space, and its drain line above the freezing point.

The METRO 120F is among the units Lifebreath describes as factory balanced: when the static pressure of the supply duct system and that of the exhaust duct system differ by 0.3 in. or less, its airflows stay within 10% of each other. We therefore take both readings at start-up.

Our team, under AirGreen's RBQ licence 5645-9605-01, installs the METRO 120F in Montreal, Laval, Longueuil, the South Shore and the North Shore.

Since October 1, 2026, Rénoclimat no longer funds HRV or ERV installations, except for a home already evaluated before the change whose post-work evaluation is done by March 31, 2027.

For an installed price, ask for a free quote at 514 316-2973 or sales@airgreen.ca: we will call you back.