191 cfm net2,300 to 3,600 sq ft60% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeLifetime core warranty
01 · Your home

Is it the right size for your home?

It delivers 191 cfm net, enough to ventilate 2,300 to 3,600 sq ft. Choose your home's living area.

It's the right size.

For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 191 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.

02 · Performance

What it does, in numbers

Heat recovery
60%
At −25 °CCode: 55% or 60% minimum
65%
At 0 °CCertified at 61 cfm
Net airflowThe ducts cost it 23 cfm
0.2 in · test bench214 cfm
0.4 in · with ducts191 cfm

$72.23

Electricity per year

Less than a 100 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

74W
Running continuously
648kWh
Per year
3months
Filter cleaning

Meets both thresholds of the Québec Construction Code (art. 9.36.3.9). At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 60% at 70 cfm (HVI).

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 74 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

DoorDoor balancing ports, adjustable dampers

The ports used to measure supply and exhaust airflow are on the door, and the dampers are adjustable. Three high speeds are selected by DIP switch (Hi 3 is the factory setting).

HooksHangs from supplied S hooks and straps

Four threaded inserts at the cabinet corners take the “S” hooks and hanging straps supplied with the unit. Allow 25 in of clearance in front of the door for service.

60%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 70 cfm.

DamperIt defrosts with indoor air

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.

HRVIt recovers heat, not moisture

Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.

2505109Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−23 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 214 to 191 cfm. Most spec sheets show only the first number, precisely because it looks better.

74 WMeasured at the airflow it actually runs at

Its 65% at 0 °C is certified at 61 cfm, the continuous airflow of a typical home. At that setting it draws 74 W, or about 648 kWh a year.

LifetimeThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years.

6 inWhat it needs on site

6 in ducts, top and side connection and a condensate drain. It weighs 71 lb, and it needs enough clearance to slide the core out for cleaning.

04 · Installation

What it needs on site

6 in ductsCollar diameter
Top and side connectionTwo on top, two on the sides
Condensate drainRequired
71 lbUnit weight
33.63 × 15 × 19 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
214 cfm
Net airflow at 0.4 in. w.g.
191 cfm
SRE at 0 °C (61 cfm)
65%
SRE at −25 °C (70 cfm)
60%
ASE at 0 °C
71%
Power draw
74 W
Efficacy
0.8 cfm/W
Type
HRV
Connection
Top and side ports
Duct collars
6 in
Condensate drain
Required
Defrost cycle
Recirculation (motorized damper)
Filters
2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
Dimensions (L × D × H)
33.63 × 15 × 19 in
Weight
71 lb
Power supply
120 V
HVI certification (Section III)
2505109
Warranty — core
Lifetime
Warranty — motors
5 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505109). Annual consumption calculated at 74 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

191 cfm net for large homes

The Lifebreath RNC 200 is a high-airflow heat recovery ventilator (HRV): 191 cfm net at 0.4 in. of static pressure and 214 cfm at 0.2 in.

The longer the duct network, the higher the static pressure and the lower the airflow. The RNC 200 has reserve on that front: its spec sheet still gives it 153 cfm net at 0.6 in.

A Cross-Flow Core

Its thermally conductive cross-flow core is easily removed for cleaning or service. At 0°C and 61 cfm, HVI rates it at 65% sensible recovery. At −25°C and 70 cfm, its sensible recovery efficiency is 60% (HVI directory, November 4, 2026 edition). The Québec Construction Code (art. 9.36.3.9) requires at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at no less than 22 L/s. The RNC 200 therefore meets both thresholds.

To be frank: a counter-flow hexagonal core recovers more heat. The RNC 205 PLUS, which has one, gets 88% at 0°C and 73% at −25°C in the HVI directory, but it delivers only 153 cfm net at 0.4 in. The RNC 200 is therefore chosen for its airflow, when the home needs it; if our visit shows the home needs less, we will offer you a more efficient model.

Power Use

At the 61 cfm (29 L/s) test point, the RNC 200 draws 74 W, or 0.8 cfm per watt, and its spec sheet lists a current of 2.2 A at 120 V. Running continuously at that setting, that comes to about 648 kWh a year, around $72 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh). Defrost is handled by an intelligent recirculating damper.

Balancing at the Door

The ports used to measure the fresh-air and stale-air flows are on the door, and the dampers are adjustable. Lifebreath gives the high speed three DIP-switch settings, with Hi 3 from the factory, and its installation manual provides a chart specific to the RNC 200 for reading the airflows at the door ports, with the unit left on that factory setting. This balancing brings in as much fresh air as it sends out stale air.

Hanging and Clearance

Four threaded inserts at the cabinet corners take the "S" hooks and hanging straps supplied with the unit. For servicing, keep 25 in. (635 mm) clear in front of the door, as Lifebreath recommends.

Dimensions and Connections

The cabinet measures 33 5/8 × 15 × 19 in. (854 × 381 × 482 mm) and weighs 71 lb (32 kg). All ducts use 6 in. (152 mm) round collars. A drain is required: its two drain spouts have an outside diameter of 12 mm (1/2 in.).

Filters

Two washable MERV 6 filters protect the core, on the stale air and on the fresh air. The MERV 13 upgrade is part number 65-195-6R.

Warranty

Lifebreath warrants the core for life, and the motors and parts for 5 years.

Which Home It Suits

With its 191 cfm net, the RNC 200 is aimed at the large home: several bedrooms and bathrooms, a finished basement with a playroom or office, or a mechanical room at one end of the house, from which long ducts run. Its 71 lb weight calls for solid fastening to the joists; the supplied hooks and straps are there for that.

Installation by AirGreen in Greater Montreal

We assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement) and compare them with the RNC 200's 191 cfm net. On a large home, we also look at the length and diameter of the planned ducts: beyond 10 ft (3.3 m), Lifebreath calls for rigid ducting, sealed and insulated. Lifebreath's dual hood, limited to 140 cfm, stays below this unit's airflow: we then plan two separate outdoor hoods.

The unit is installed level, a condition Lifebreath sets for condensate drainage, then the P-trap is assembled with the tee connector pointing up and primed with a cup of water poured into the drain pan. At start-up, the RNC 200 runs on high speed and we reduce the stronger airflow until the fresh air and the stale air are even.

We work in Montreal and Laval, in Longueuil and on the South Shore, as well as on the North Shore.

Since October 1, 2026, Rénoclimat no longer funds HRV or ERV installations, except for a home already evaluated before the change whose post-work evaluation is done by March 31, 2027.

For an installed price, ask for a free quote at 514 316-2973 or sales@airgreen.ca.