Lifebreath RNC6-HEX-TPD HRV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 89 cfm net, enough to ventilate 1,000 to 1,600 sq ft. Choose your home's living area.
It's the right size.
For a 900 to 1,500 sq ft home, about 63 cfm of air needs to be renewed continuously. This unit delivers 89 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$63.44
Electricity per year
Less than a 100 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets both thresholds of the Québec Construction Code (art. 9.36.3.9). At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 65% at 66 cfm (HVI).
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 65 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
HEXPatented counter-flow HEX core
Lifebreath describes it as a patented counter-flow HEX core unit offering higher efficiency with the same features as the RNC5 series. The core is easily removed for cleaning.
DampersBalancing damper on every oval collar
The 5 in oval collars on top each have a balancing damper, and the measuring ports are on the door. The high speed is selected by DIP switch (Hi 3 from the factory).
65%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 66 cfm.
DamperIt defrosts with indoor air
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.
2505103Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−15 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 104 to 89 cfm. Most spec sheets show only the first number, precisely because it looks better.
65 WMeasured at the airflow it actually runs at
Its 75% at 0 °C is certified at 64 cfm, the continuous airflow of a typical home. At that setting it draws 65 W, or about 569 kWh a year.
LifetimeThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
5 inWhat it needs on site
5 in (oval) ducts, top connection and a condensate drain. It weighs 57 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 104 cfm
- Net airflow at 0.4 in. w.g.
- 89 cfm
- SRE at 0 °C (64 cfm)
- 75%
- SRE at −25 °C (66 cfm)
- 65%
- ASE at 0 °C
- 79%
- Power draw
- 65 W
- Efficacy
- 1.0 cfm/W
- Type
- HRV
- Connection
- Top ports
- Duct collars
- 5 in (oval)
- Condensate drain
- Required
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- 2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
- Dimensions (L × D × H)
- 33.6 × 15.1 × 18.7 in
- Weight
- 57 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505103
- Warranty — core
- Lifetime
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505103). Annual consumption calculated at 65 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
HEX core and damper defrost: 65% at −25 °C
For a home that faces harsh cold, the Lifebreath RNC6-HEX-TPD keeps up its performance at −25 °C. This heat recovery ventilator (HRV) pairs the patented counter-flow HEX core with recirculating damper defrost. At −25 °C and 66 cfm, its sensible recovery efficiency is 65% (HVI directory, November 4, 2026 edition); the Québec Construction Code (art. 9.36.3.9) requires at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at a minimum of 22 L/s. The RNC6-HEX-TPD therefore meets both thresholds.
On airflow, it delivers 104 cfm net at 0.2 in. of static pressure and 89 cfm at 0.4 in. That is a modest airflow.
The HEX core
Lifebreath presents the RNC6-HEX-TPD as a patented HEX core unit that offers higher efficiency while keeping all the features of the RNC5 series. In this counter-flow core, the stale air going out and the fresh air coming in travel in opposite directions, each in its own channels, and heat passes from one to the other. HVI rates its sensible recovery efficiency at 75% at 0 °C, at the 64 cfm test airflow. For cleaning or service, the core is easily removed.
Why damper defrost
In deep cold, moisture in the stale air can freeze in the core. The recirculating damper takes care of it: during defrost, house air, not outdoor air, flows through the core, and the frost melts. Lifebreath calls this system intelligent. The RNC5-HEX-TPF, which also uses the HEX core, works differently: a temperature sensor periodically shuts down its fresh-air motor.
Energy use
Lifebreath gives each airstream its own motorized impeller, which runs at several speeds. HVI measures 65 W at the 64 cfm test point, or 1.0 cfm per watt. Running continuously at that setting, that comes to about 569 kWh a year, around $63 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh). At the same test point, the RNC5-HEX-TPF draws 31 W, but its efficiency at −25 °C drops to 57% (at 70 cfm). The choice between the two therefore depends on what matters most to you: cold-weather performance or energy use. The RNC6-HEX-TPD is also on Natural Resources Canada's ENERGY STAR list; Lifebreath states that it meets the requirements in Canada only.
Connections and balancing
Lifebreath describes it as a top-ported unit: all the ducts connect there to 5 in. oval collars. Each collar has its own balancing damper, and the measuring ports are on the door. The high-speed setting is made with DIP switches, and Lifebreath ships it at Hi 3. With this vertical connection, the ducts come straight from the joists.
Installation
The cabinet measures 33.6 in. long, 15.1 in. deep and 18.7 in. high, and weighs 57 lb. It is made of 22-gauge prepainted galvanized steel, and its insulation keeps condensation from forming on the outside. It hangs from four threaded inserts, one at each corner of the cabinet, which take the “S” hooks and straps supplied with the unit. The drain is mandatory and connects to two fittings with an outside diameter of 1/2 in. (12 mm). In front of the door, leave 25 in. clear: that is the clearance Lifebreath recommends for service. The wall control is optional; it connects with 3-wire, 20-gauge (minimum) wire, 100 ft long at most.
Filters
Each of the two airstreams goes through a washable MERV 6 filter, on the stale-air side and on the fresh-air side. For finer filtration, Lifebreath part 65-195-6R replaces them with MERV 13 filters.
Warranty
Lifebreath's warranty covers the core for life, and the motors and parts for 5 years.
Which home it suits
The RNC6-HEX-TPD suits a small or mid-sized house that faces harsh winters: a corner house, a house on open, windswept land. If your home needs more fresh air, we will suggest a higher-capacity model.
Installation by AirGreen in Greater Montreal
It all starts at your home: we assess on site the ventilation needs of the bedrooms, bathrooms, kitchen and basement, then we check that the RNC6-HEX-TPD's 89 cfm net at 0.4 in. is enough with the planned duct run. We also look for a heated spot for this air exchanger, in the mechanical room or near an outside wall, where its 33.6 in. length and the 25 in. clearance in front of the door will fit. Lifebreath does not recommend the attic.
On start-up day, the two airflows are balanced right at the unit, using the measuring ports on the door and the damper on each collar. As Lifebreath requires, the unit runs at high speed while we turn down the stronger airflow until the air coming into the house equals the air exhausted outside. The unit is installed level, a Lifebreath requirement for condensate drainage. The drain's P-trap and tubing stay below the bottom of the door, sloping down 1/4 in. per foot away from the unit, and a cup of water poured into the drain pan creates the water seal that keeps odours from being drawn into the fresh air. The fresh-air and stale-air ducts leading to the outdoor hoods are insulated back to the unit, as Lifebreath's installation manual specifies.
AirGreen serves Montreal, Laval, Longueuil, the North Shore and the South Shore.
Since October 1, 2026, Rénoclimat no longer funds HRV or ERV installations, except for a home already evaluated before the change whose post-work evaluation is done by March 31, 2027.
Ask for your free quote: 514 316-2973 or sales@airgreen.ca. We will call you back to go over your project.