Air Exchanger VENMAR AVS® AI2 SERIES A210E75RT Greater Montreal
Is it the right size for your home?
It delivers 206 cfm net, enough to ventilate 2,400 to 3,900 sq ft. Choose your home's living area.
It's the right size.
For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 206 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$27.33
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets both thresholds of the Québec Construction Code (art. 9.36.3.9). At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 65% at 83 cfm (HVI).
Airflow and efficiency: manufacturer's data; airflow at 0.4 in and power draw from the V210E75RT spec sheet. Cost: 28 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
−30 cfmTakes 30 cfm off to protect the core membrane
On the 210 cfm ERVs, if the maximum airflow reached during auto-balancing is 160 cfm or less, the unit reduces airflow by 30 cfm to prevent ERV core membrane deformation at static pressure over 1.3 in w.g.
40 °CCooling fan for the electronics
The 210 and 230 cfm models have a fan in the electrical box that can start when the temperature near the unit exceeds 40 °C. If the electronics overheat, the unit temporarily reduces power to the motors.
65%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 83 cfm.
DamperIt defrosts with indoor air
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
−4 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 210 to 206 cfm. Most spec sheets show only the first number, precisely because it looks better.
28 WMeasured at the airflow it actually runs at
Its 81% at 0 °C is measured at 64 cfm, the continuous airflow of a typical home. At that setting it draws 28 W, or about 245 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
6 inWhat it needs on site
6 in ducts, top connection. It weighs 47 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 210 cfm
- Net airflow at 0.4 in. w.g.
- 206 cfm
- SRE at 0 °C (64 cfm)
- 81%
- SRE at −25 °C (83 cfm)
- 65%
- ASE at 0 °C
- 84%
- Power draw
- 28 W
- Efficacy
- 2.3 cfm/W
- Type
- ERV
- Connection
- Top ports
- Duct collars
- 6 in
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- Washable MERV 8 filter and washable exhaust filter included
- Dimensions (L × D × H)
- 24.81 × 21 × 21.69 in
- Weight
- 47 lb
- Power supply
- 120 V
- Warranty — core
- 5 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
Manufacturer's published data for this model; airflow at 0.4 in and power draw from the V210E75RT spec sheet, a model with identical published ratings. Annual consumption calculated at 28 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
More airflow than the A180E75RT in the same cabinet: the A210E75RT
The A210E75RT shares the cabinet and the 6 in. top collars of the A180E75RT ERV, but its continuous airflow goes up to 210 cfm instead of 189. In the cold, the two tables are nearly even: 65% at −25 °C for this one, 64% for the A180E75RT, both at 83 cfm. You pick it for the extra airflow headroom, when the on-site assessment calls for it. Its twin, the A210E75RS, carries the same collars on the side.
It ships with a washable MERV 8 filter, which guide 23831 says to vacuum and wash every 3 months. For finer filtration, Venmar offers an optional MERV 13 filter, part V24300.
Sources: manufacturer's pages for the A210E75RT and the A180E75RT (viewed Nov. 23, 2026); installation guide 23831.
Sold and installed by AirGreen