Air Exchanger VENMAR AVS® N SERIES A160E65RT Greater Montreal

In stock
SKU: A160E65RT
142 cfm net1,700 to 2,700 sq ft56% at −25 °C
Talk to an HVAC technician · 514 316-2973
Core warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 142 cfm net, enough to ventilate 1,700 to 2,700 sq ft. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 142 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.

02 · Performance

What it does, in numbers

Heat recovery
56%
At −25 °CCode: 55% or 60% minimum
76%
At 0 °CMeasured at 38 cfm
Net airflowThe ducts cost it 8 cfm
0.2 in · test bench150 cfm
0.4 in · with ducts142 cfm

$14.64

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

15W
Running continuously
131kWh
Per year
3months
Filter cleaning

Meets the Code's 55% threshold; below the 60% it requires where there are 6,000 degree-days or more. At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 56% at 66 cfm (HVI).

Airflow and efficiency: manufacturer's data; airflow at 0.4 in and power draw from the V160E65RT spec sheet. Cost: 15 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

35–150 cfmChoose 35 to 150 cfm right on the unit

Airflow is selected on the built-in LCD, which also shows measured airflow in real time and doubles as a diagnostic tool. Virtuo then takes care of balancing automatically.

Sup/exhSupply and exhaust airflows can be set separately

Holding + and − together for 4 seconds lets the installer set the fresh-air supply and the stale-air exhaust airflows separately, right on the unit's screen.

56%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 66 cfm.

DamperIt defrosts with indoor air

In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

−8 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 150 to 142 cfm. Most spec sheets show only the first number, precisely because it looks better.

15 WMeasured at the airflow it actually runs at

Its 76% at 0 °C is measured at 38 cfm, the continuous airflow of a typical home. At that setting it draws 15 W, or about 131 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors and parts: 5 years.

6 inWhat it needs on site

6 in ducts, top connection. It weighs 37 lb, and it needs enough clearance to slide the core out for cleaning.

04 · Installation

What it needs on site

6 in ductsCollar diameter
Top connectionTop ports
37 lbUnit weight
21 × 16.3 × 21.5 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
150 cfm
Net airflow at 0.4 in. w.g.
142 cfm
SRE at 0 °C (38 cfm)
76%
SRE at −25 °C (66 cfm)
56%
ASE at 0 °C
81%
Power draw
15 W
Efficacy
2.5 cfm/W
Type
ERV
Connection
Top ports
Duct collars
6 in
Defrost cycle
Recirculation (motorized damper)
Filters
Washable MERV 8 filter and washable exhaust filter included (kit SV66133)
Dimensions (L × D × H)
21 × 16.3 × 21.5 in
Weight
37 lb
Power supply
120 V
Warranty — core
5 years
Warranty — motors
5 years
Warranty — parts
5 years

Manufacturer's published data for this model; airflow at 0.4 in and power draw from the V160E65RT spec sheet, a model with identical published ratings. Annual consumption calculated at 15 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The next model down and up

Talk to an HVAC technician before you choose

We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

Same cabinet as the A130E65RT, 6 in. collars: meet the A160E65RT

From the outside, the A160E65RT looks a lot like the A130E65RT: the same top-port cabinet and the same 37 lb on the spec table. The difference is at the connections. Its collars are 6 in. instead of 5 in., and its airflow range reaches higher. It is the N Series ERV to look at when your ducts are already 6 in., or when the on-site assessment shows the house needs more air than the A130E65RT delivers. For side connections, its twin is the A160E65RS.

At the fall service, its core is handled like any ERV core: guide 23831 says to vacuum it and never soak it. Only an HRV core goes into soapy water.

Sources: manufacturer's pages for the A160E65RT and the A130E65RT (viewed Nov. 23, 2026); installation guide 23831.