Air Exchanger VENMAR AVS® N SERIES A160E65RT Greater Montreal
Is it the right size for your home?
It delivers 142 cfm net, enough to ventilate 1,700 to 2,700 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 142 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$14.64
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Code's 55% threshold; below the 60% it requires where there are 6,000 degree-days or more. At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 56% at 66 cfm (HVI).
Airflow and efficiency: manufacturer's data; airflow at 0.4 in and power draw from the V160E65RT spec sheet. Cost: 15 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
35–150 cfmChoose 35 to 150 cfm right on the unit
Airflow is selected on the built-in LCD, which also shows measured airflow in real time and doubles as a diagnostic tool. Virtuo then takes care of balancing automatically.
Sup/exhSupply and exhaust airflows can be set separately
Holding + and − together for 4 seconds lets the installer set the fresh-air supply and the stale-air exhaust airflows separately, right on the unit's screen.
56%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 66 cfm.
DamperIt defrosts with indoor air
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
−8 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 150 to 142 cfm. Most spec sheets show only the first number, precisely because it looks better.
15 WMeasured at the airflow it actually runs at
Its 76% at 0 °C is measured at 38 cfm, the continuous airflow of a typical home. At that setting it draws 15 W, or about 131 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
6 inWhat it needs on site
6 in ducts, top connection. It weighs 37 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 150 cfm
- Net airflow at 0.4 in. w.g.
- 142 cfm
- SRE at 0 °C (38 cfm)
- 76%
- SRE at −25 °C (66 cfm)
- 56%
- ASE at 0 °C
- 81%
- Power draw
- 15 W
- Efficacy
- 2.5 cfm/W
- Type
- ERV
- Connection
- Top ports
- Duct collars
- 6 in
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- Washable MERV 8 filter and washable exhaust filter included (kit SV66133)
- Dimensions (L × D × H)
- 21 × 16.3 × 21.5 in
- Weight
- 37 lb
- Power supply
- 120 V
- Warranty — core
- 5 years
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
Manufacturer's published data for this model; airflow at 0.4 in and power draw from the V160E65RT spec sheet, a model with identical published ratings. Annual consumption calculated at 15 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
Same cabinet as the A130E65RT, 6 in. collars: meet the A160E65RT
From the outside, the A160E65RT looks a lot like the A130E65RT: the same top-port cabinet and the same 37 lb on the spec table. The difference is at the connections. Its collars are 6 in. instead of 5 in., and its airflow range reaches higher. It is the N Series ERV to look at when your ducts are already 6 in., or when the on-site assessment shows the house needs more air than the A130E65RT delivers. For side connections, its twin is the A160E65RS.
At the fall service, its core is handled like any ERV core: guide 23831 says to vacuum it and never soak it. Only an HRV core goes into soapy water.
Sources: manufacturer's pages for the A160E65RT and the A130E65RT (viewed Nov. 23, 2026); installation guide 23831.