ARCOAIRE D5FUHAH Electric Furnace | 3 Tons - 36000 BTU - R454B

In stock

Arcoaire’s 3-ton D5FUHAH air handler: the R-454B Crossover indoor unit, multiposition, designed for high-static duct systems.

Model numberD5FUHAH36XAK

1,147.8 CFMhigh-speed airflow (AHRI 210/240 conditions)
17.52 incabinet width
R-454Bwith refrigerant detection sensor
R-454B115 V or 208/230 V · single phaseRefrigerant detection sensorFilter up to 16 x 20 in
Series
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberD5FUHAH36XAK
ManufacturerArcoaire
Size3 tons (36,000 BTU/h)
High-speed airflow1,147.8 CFM
RefrigerantR-454B
Width x depth17.52 x 21.5 in
Outdoor unitsD5CUHAH series

The 3-ton Crossover air handler, built for demanding ductwork

Three tons on R-454B: what sets it apart

Arcoaire offers several 3-ton air handlers. The D5FUHAH36XAK is the one for Crossover systems: it runs exclusively on R-454B, has a built-in refrigerant detection sensor and matches the D5CUHAH outdoor units. If you are starting fresh with a complete Crossover system, this is the cabinet that goes indoors.

It suits multi-storey homes, cottages and semi-detached homes whose ductwork serves several distant rooms. It does not replace an air handler connected to an outdoor unit that uses another refrigerant.

The cabinet is multiposition, which gives room to orient it according to the space available and the route of the existing ducts. Its refrigerant connections are 3/8 in for the liquid line and 3/4 in for suction.

Long duct runs, serious filtration

In a two-storey house, air has to travel long distances and pass through several elbows before reaching the bedrooms. Arcoaire presents the D5FUHAH as a high-static air handler, designed for those systems. At high speed, it moves 1,147.8 CFM under AHRI 210/240 rating conditions.

Filtration is another strength. The standard 4 in magnetic rack takes a 1, 2 or 4 in thick filter, up to 16 x 20 in. A thicker filter offers more filtering surface and usually needs replacing less often, an advantage for families with pets or homes near a busy road.

On noise, the manufacturer publishes 33 dB(A) at 1 m at low speed and 46.5 dB(A) at high speed. Finally, the cabinet accepts a 115 V or 208/230 V supply; we choose based on the capacity of your electrical panel.

Installation by AirGreen, step by step

During the free in-home estimate, we assess the ductwork, the location and the power supply, and we measure the space, since the cabinet height is confirmed with the installation documentation. You then receive a written quote.

Our technicians set the 17.52 in wide cabinet, connect the refrigerant line set, the drain and the electrical supply, then commission the system and check the airflow at the registers. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. A family business established in Montreal for more than fifteen years, AirGreen also serves the North Shore, Laval, Longueuil and the South Shore.

Let’s start with a visit

Sold alone, this air handler does not qualify for the LogisVert grant, which follows a certified outdoor unit + air handler pair. For a complete D5CUHAH + D5FUHAH system, we prepare a quote that takes it into account.

Ask for your free on-site estimate and receive a written quote. Financing is available.

01 · What it is for

The 3-ton size of the Crossover system

The D5FUHAH36XAK installs indoors and works with an Arcoaire D5CUHAH outdoor unit. Designed for high-static duct systems, it moves 1,147.8 CFM at high speed and runs exclusively on R-454B.

  • Multi-storey homes and cottages with extensive ductwork
  • 3-ton Arcoaire central systems with a D5CUHAH outdoor unit
  • Projects that want thicker filtration: 4 in magnetic rack
  • Locations supplied with 115 V or 208/230 V
For demanding ductworkHigh-static cabinet: 1,147.8 CFM at high speed under AHRI 210/240 rating conditions.
1 to 4 in filtration4 in magnetic rack as standard; 16 x 20 in filter maximum (W x D), 1, 2 or 4 in thick.
33 dB(A) at low speedPublished sound pressure at 1 m: 46.5 / 45 / 33 dB(A) (high / medium / low).
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerArcoaire
TypeHigh-static Crossover multiposition air handler
Nominal size3 tons (36,000 BTU/h)
RefrigerantR-454B only, built-in refrigerant detection sensor
Airflow1,147.8 CFM at high speed (AHRI 210/240 rating conditions)
Sound level46.5 / 45 / 33 dB(A) at 1 m (high / medium / low)
Power supply115 V or 208/230 V, single phase, 60 Hz
MCA8 A (115 V) / 6 A (208/230 V)
Max. overcurrent protection15 A
Liquid connection3/8 in (9.52 mm)
Suction connection3/4 in (19 mm)
Filter4 in magnetic rack as standard (1, 2 or 4 in filter); 16 x 20 in filter maximum (W x D)
Width x depth17.52 x 21.5 in (445 x 546 mm)
Net weight149.25 lb (67.7 kg)
Matched outdoor unitsD5CUHAH series
Model numberD5FUHAH36XAK
03 · Before installing

What to know before installing

  • Sold alone: not eligible for the LogisVert grant. The grant follows the certified outdoor unit + air handler pair.
  • Runs exclusively on R-454B, with an outdoor unit designed for that refrigerant; Arcoaire matches it with the D5CUHAH outdoor units.
  • Width x depth: 17.52 x 21.5 in (445 x 546 mm). We confirm the exact height with the installation documentation before reserving the location.
  • At 115 V, 8 A minimum circuit ampacity; at 208/230 V, 6 A; 15 A maximum overcurrent protection.
  • Electric backup heat is not in the confirmed data for this model: we check the compatible option before ordering.
  • Net weight of 149.25 lb (67.7 kg): installation takes two people and proper support.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces – air handlers
See all
Same brand
ARCOAIRE
See all
06 · Questions

Frequently asked questions

How do I choose between the 3-ton air handlers in the range?

They differ by refrigerant, width and motor. The D5FUHAH36XAK is the only one designed for R-454B; it is 17.52 in wide. Send us the model of your outdoor unit and we confirm the right air handler.

Can I connect it to my existing outdoor unit?

Only if it runs on R-454B: the cabinet is designed exclusively for that refrigerant. Arcoaire matches it with the D5CUHAH outdoor units.

What filter does it use?

The standard 4 in magnetic rack takes a 1, 2 or 4 in thick filter, up to 16 x 20 in (W x D).

Does this air handler qualify for a grant?

Not when it is sold alone. Hydro-Québec’s LogisVert grant follows a certified outdoor unit + air handler pair. For a complete system, ask us for a quote.

Can you install it?

Yes. Our technicians set the cabinet, connect it to the ductwork, the refrigerant line set, the drain and the power supply, then commission the system.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-ton Arcoaire D5FUHAH air handler, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom