PTAC: Friedrich | Heat Pump 7,000 BTU | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for this room?
Friedrich doesn't publish a room size for this unit. From its 7,200 BTU/h of cooling, we estimate ≈ 105 to 170 sq ft. Choose your room's area.
It's the right size.
For a 130 to 175 sq ft room, this is the range we estimate for this unit: 7,200 BTU/h of cooling, 6,000 BTU/h of heat-pump heating and a heater of up to 3,450 W when the cold calls for it.
AirGreen estimate: Friedrich publishes no room size for its PTACs, so this range is a guide based on cooling capacity. Our estimator confirms the exact area on site.
What it does, in numbers
$12.35
Cooling, all summer
Less than a 60 W light bulb
Bulbs left on day and night for a year. Cooling: 5 h a day for 40 days, the assumption used by Hydro-Québec's air-conditioning calculator. Same calculation for every line: wattage × hours × 11.142 ¢/kWh.
≈$101
Heating, all winter
≈ $8 less than baseboard heaters
Typical 138 sq ft room with one exterior wall, in Montréal: 982 kWh of heat per winter (Environment Canada 1991–2020 climate normals). The heat pump is counted only at 8 °C and warmer, where Friedrich rates its output; below that, the heater, at the price of a baseboard. If it keeps heating in colder weather, the bill goes down.
≈ $114 for the year, before tax. Winter is 89% of it. If your home stays in the first tier of Rate D in summer (7.065 ¢/kWh), cooling drops to $7.83.
Capacities and currents: Friedrich ZoneAire Premier product profile PP_PTACPRE_2023 (rev. 2-20-23) and installation manual 9830 1000_00. Power draw: 554 W in cooling (7,200 BTU/h ÷ EER 13.0), 485 W in heat-pump mode, 3,450 W on the 3.5 kW heater. Hydro-Québec Rate D in effect since April 1, 2026: 11.142 ¢/kWh second tier, before tax.
What you should know about this one
Published, verifiable facts, not brochure claims.
7,200What it really delivers in cooling
The name says 7,000 BTU: that's the unit's size class. Friedrich publishes 7,200 BTU/h at 230 V, a little more than its size class, and 7,000 at 208 V, the supply in many buildings.
3,450 WThe heater that takes over
The "3" in PDH07K3SG sets the heater at 3.5 kW: 3,450 W and 11,700 BTU/h at 230 V, 2,821 W at 208 V, on a 6-20P plug and a 20 A circuit. It heats when the heat pump can no longer keep up.
3.6The COP published at 8 °C
Friedrich publishes a heat-pump COP of 3.6: 6,000 BTU/h of heat at 230 V. Each kWh you pay for gives back 3.6 in heat, against 1 for the heater or a baseboard.
5,000What it still heats at 3 °C outside
At 37 °F (3 °C) outside, Friedrich still publishes 5,000 BTU/h of heat-pump heating for this model, against 6,000 at 47 °F (8 °C). Output drops with the cold, but the heat pump keeps working.
−1 °CWhen the heat pump steps aside
According to Friedrich's installation manual, the compressor stops when the outdoor coil stays below about 30 °F (−1 °C); the heater then works alone, and the heat pump restarts once the coil warms up.
1.7Pints of water it removes per hour
The dehumidification Friedrich publishes in cooling mode: 1.7 US pints per hour. It's what keeps a room comfortable in summer without it turning clammy.
75 cfmFresh air through the vent door
The vent door brings in up to 75 cfm of outside air, according to Friedrich. Close it to keep all the heat or the cool air in the room.
6-20PThe plug it needs
This model's NEMA 6-20P plug goes into a 6-20R outlet on a dedicated 20 A circuit. In a replacement, we first check the outlet and breaker already in place.
It fits a standard PTAC sleeve, with no baffle kit
Friedrich designs this PTAC for the standard 42 × 16 in sleeve, without the added cost of a baffle kit. Our estimator checks the sleeve and the grille in place before ordering.
What it needs on site
In a replacement, we check the outlet and the breaker first: they set the heater size you can use. Our estimator confirms the sleeve, the outlet and the slope before ordering.
Complete spec sheetData and cited sources
- Model
- PDH07K3SG
- Cooling capacity (208/230 V)
- 7,000 / 7,200 BTU/h
- Heating capacity, heat pump (208/230 V)
- 5,800 / 6,000 BTU/h
- Electric heater
- 3.5 kW (2,821 / 3,450 W at 208/230 V)
- EER
- 13.0
- COP (heat pump, 47 °F / 8.3 °C)
- 3.6
- Current — cooling (208/230 V)
- 2.9 / 2.7 A
- Current — heat-pump heating (208/230 V)
- 2.6 / 2.4 A
- Power — cooling (230 V)
- 550 W
- Power — heat pump (230 V)
- 485 W
- Airflow (low/high)
- 270 / 345 cfm
- Dehumidification
- 1.7 US pints/h
- Application range
- AirGreen guide ≈ 105 to 170 sq ft (based on capacity); room size confirmed on site
- Dimensions
- 42 × 21 ½ × 16 in (W × D × H, with front)
- Sleeve
- 42 × 16 × 13 ¾ in
- Net weight
- 113 lb
- Refrigerant
- R-410A · 34 oz
- Heat pump → heater
- outdoor coil below about 30 °F (−1 °C), per the installation manual
- Power supply
- 208/230 V · 1 ph · 60 Hz
All values: Friedrich ZoneAire Premier product profile PP_PTACPRE_2023 (rev. 2-20-23) and installation manual 9830 1000_00. Operating cost: cooling at 554 W for 200 h per summer; heating estimated for a typical 138 sq ft room (982 kWh of heat per winter, heat pump counted at 8 °C and warmer); at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The neighbouring models
Talk to an HVAC technician before you choose
We check the existing sleeve, the outlet and the heater size, and give you an installed price. For a building, we order the same series for every room.
Friedrich PTAC PDH07K3SG: 7,000 BTU heat pump with a 3.5 kW backup heater
The PDH07K3SG is a packaged terminal unit (PTAC) from the ZoneAire Premier series: it slides into a 42 × 16 in wall sleeve in the outside wall, and the whole system sits inside the unit. No outdoor unit, no refrigerant piping on site, and every room keeps its own thermostat.
Its edge: it is the most efficient of our PTAC heat pumps, with a COP of 3.6 at 47 °F outside. At that rating point, each kWh you pay for in heat-pump mode gives back 3.6 in heat, compared with 1 for the heater.
What sets it apart
- 7,200 BTU/h of cooling at 230 V (7,000 at 208 V), 7,000 BTU class, with an EER of 13.0.
- 6,000 BTU/h of heat-pump heat at 230 V (5,800 at 208 V), rated by Friedrich at 47 °F outside, with a COP of 3.6.
- 3.5 kW heater (3,450 W at 230 V, 2,821 W at 208 V) that takes over when it is too cold for the heat pump.
- 345 CFM of airflow on high (270 on low), and 1.7 US pints of water removed per hour in cooling.
- Two permanently lubricated fan motors, for quiet operation.
- Constant fan mode, at the owner’s choice.
Which room it suits
Friedrich publishes no room size for its PTACs: the tool on this page gives an AirGreen guide based on capacity, and AirGreen confirms the size with an on-site assessment of your heating and cooling needs. Larger room: PDH09K3SG. Same size, cooling with electric heat: PDE07K3SG.
Installed by AirGreen
Our refrigeration technicians and electricians, under AirGreen’s RBQ licence 5645-9605-01 (subclasses 15.10 and 16), set the unit in a standard 42 × 16 in sleeve, with no baffle kit, and plug it in (cord PXPC23020A, NEMA 6-20P plug) to a 6-20R outlet on a dedicated 20 A circuit. For a replacement, we check the sleeve and grille in place before ordering.
Warranty: 6 years on the compressor, 6 years on parts and 6 years on labour. Friedrich’s published limited warranty for units sold after September 30, 2026 is 2 years on parts and labour, and 5 years on the sealed system, parts and labour.
Sold and installed by AirGreen. Free on-site estimate anywhere in Montreal, Laval, Longueuil, the South Shore and the North Shore: 514 316-2973.