PTAC SENVILLE R32 | 12000 BTU | Montreal, Laval, South Shore
Is it the right size for this room?
Senville doesn't publish a room size for this unit. From its 12,000 BTU/h of cooling, we estimate ≈ 170 to 255 sq ft. Choose your room's area.
It's the right size.
For a 175 to 225 sq ft room, this is the range we estimate for this unit: 12,000 BTU/h of cooling, 10,800 BTU/h of heat-pump heating and a heater of up to 3,500 W when the cold calls for it.
AirGreen estimate: Senville publishes no room size, so we apply the application ranges Trane publishes for its PTACs of the same cooling capacity. Our estimator confirms the exact area on site.
What it does, in numbers
$23.24
Cooling, all summer
Less than a 60 W light bulb
Bulbs left on day and night for a year. Cooling: 5 h a day for 40 days, the assumption used by Hydro-Québec's air-conditioning calculator. Same calculation for every line: wattage × hours × 11.142 ¢/kWh.
≈$157
Heating, all winter
≈ $13 less than baseboard heaters
Typical 213 sq ft room with one exterior wall, in Montréal: 1,518 kWh of heat per winter (Environment Canada 1991–2020 climate normals). The heat pump is counted only at 8 °C and warmer, where Senville rates its output; below that, the heater, at the price of a baseboard. If it keeps heating in colder weather, the bill goes down.
≈ $180 for the year, before tax. Winter is 87% of it. If your home stays in the first tier of Rate D in summer (7.065 ¢/kWh), cooling drops to $14.74.
Capacities and currents: Senville SENPT product pages (senville.com, accessed September 22, 2026). Power draw: 1,043 W in cooling (12,000 BTU/h ÷ EER 11.5), 890 W in heat-pump mode, 3,500 W on the 3.5 kW heater. Hydro-Québec Rate D in effect since April 1, 2026: 11.142 ¢/kWh second tier, before tax.
What you should know about this one
Published, verifiable facts, not brochure claims.
12,000What it really delivers in cooling
The name says 12,000 BTU: that's the unit's size class. Senville publishes 12,000 BTU/h at 230 V, and 11,800 at 208 V, the supply in many buildings.
3,500 WThe heater that takes over
Senville fits the same 3.5 kW heater on every size: 3,500 W at 230 V, 2,897 W at 208 V, on a 20 A cord with a built-in resettable breaker. It heats when the heat pump can no longer keep up.
3.2The COP published at 8 °C
Senville publishes a heat-pump COP of 3.2: 10,800 BTU/h of heat at 230 V. Each kWh you pay for gives back 3.2 in heat, against 1 for the heater or a baseboard.
−5 °CThe lowest heating temperature published
Senville publishes a heating range of 23 to 76 °F outside (−5 to 24 °C) for the heat pump. Below that range, the 3.5 kW heater heats the room.
51.5 dBThe noise at low speed
51.5 dB(A) at low speed, 52 at high speed, as published by Senville. In a bedroom, that's the number that decides the complaints: the unit runs at night, two metres from the bed.
What it needs on site
In a replacement, we check the outlet and the breaker first: they set the heater size you can use. Our estimator confirms the sleeve, the outlet and the slope before ordering.
Complete spec sheetData and cited sources
- Model
- SENPT-12AEN
- Cooling capacity (208/230 V)
- 11,800 / 12,000 BTU/h
- Heating capacity, heat pump (208/230 V)
- 10,500 / 10,800 BTU/h
- Electric heater
- 3.5 kW (2,897 / 3,500 W at 208/230 V)
- EER (calculated: published capacity ÷ input)
- 11.5 · published EER2 10.5
- COP (heat pump, 8 °C)
- 3.2
- Current — cooling (208/230 V)
- 5.8 / 5.3 A
- Current — heat-pump heating (208/230 V)
- 5.3 / 5 A
- Power — cooling (208/230 V)
- 1,020 / 1,040 W
- Power — heat pump (230 V)
- 890 W
- Airflow (low/high)
- 344 / 438 cfm
- Sound level (low/high)
- 51.5 / 52 dB(A)
- Application range
- ≈ 170 to 255 sq ft (AirGreen estimate)
- Dimensions
- 42.01 × 20.91 × 15.98 in (W × D × H)
- Net weight
- 110.2 lb
- Refrigerant
- R-32 · 26.81 oz
- Heat-pump heating, published range
- 23 to 76 °F outside (−5 to 24 °C)
- Power supply
- 208/230 V · 1 ph · 60 Hz
All values: Senville SENPT product pages (senville.com, accessed September 22, 2026). Operating cost: cooling at 1,043 W for 200 h per summer; heating estimated for a typical 213 sq ft room (1,518 kWh of heat per winter, heat pump counted at 8 °C and warmer); at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The neighbouring models
Talk to an HVAC technician before you choose
We check the existing sleeve, the outlet and the heater size, and give you an installed price. For a building, we order the same series for every room.
A 12,000 BTU PTAC designed for bedrooms, apartments, and spaces where a standalone unit truly simplifies installation
The 12,000 BTU SENVILLE SENPT-12AEN PTAC belongs to a category of HVAC systems that is very different from a conventional wall-mounted heat pump. Here, the evaporator, condenser, compressor, and fan are all integrated into a single unit passing through the exterior wall. No refrigerant line set between an indoor unit and an outdoor unit is required.
This design explains why PTACs remain particularly attractive for certain hotels, rental buildings, apartments, studios, residences, and buildings where each room must be able to operate independently.
At AirGreen, when we evaluate a replacement or new installation of a PTAC in Montreal, Laval, Longueuil, the South Shore, or the North Shore, we do not look only at the 12,000 BTU rating. A PTAC must be selected based on its wall opening, electrical supply, existing sleeve, outdoor grille, expected sound level, and above all its actual heating capacity in Quebec temperatures.
The SENVILLE SENPT-12AEN uses R32 refrigerant, operates on a 208/230 V single-phase, 60 Hz power supply, and combines three important functions: cooling, heat pump heating, and 3.5 kW auxiliary electric heating. The manufacturer also indicates a remote control, a digital LED panel, and compatibility with a smart control kit.
The main features of the SENVILLE SENPT-12AEN
Here is the data we consider most important for properly analyzing this PTAC:
- Model: SENPT-12AEN
- Rated cooling capacity: 12,000 BTU/h
- Heat pump heating capacity: up to 10,800 BTU/h
- Electric heating: 3.5 kW
- Refrigerant: R32
- Power supply: 208/230 V, single-phase, 60 Hz
- Plug: 20 A with built-in resettable circuit breaker
- Maximum airflow: 438 CFM
- EER2: 10.5
- Advertised COP: 3.2
- Remote control
- Digital LED control panel
- Smart kit listed as included
- Dimensions: 42.01 × 20.91 × 15.98 in
- Indoor sound level: 51.5 to 52 dB(A)
- Outdoor sound level: 67 dB(A)
- Manufacturer’s warranty listed by AirGreen: 10-10-0
- Additional warranty: available depending on the option selected
The technical table in the documentation indicates a cooling capacity of 12,000 BTU/h at 230 V and 11,800 BTU/h at 208 V, with cooling power consumption of only 1,040 / 1,020 W depending on the supply voltage. The corresponding current is 5.3 / 5.8 A.
An important detail: 12,000 BTU in cooling does not mean 12,000 BTU of heating under all conditions
This is a distinction we often explain when preparing an HVAC quote.
In cooling mode, the SENPT-12AEN provides up to 12,000 BTU/h. In heat pump mode, the stated capacity is 10,800 / 10,500 BTU/h, with power consumption of 890 / 850 W and current of 5.0 / 5.3 A. The manufacturer specifies a COP of 3.2.
This means that under conditions where the heat pump can operate normally, it produces several units of heat for every unit of electricity consumed. This is precisely the energy advantage of a heat pump over a resistive electric element.
However, the PTAC also has a 3.5 kW electric heating element. Its stated capacity reaches 10,900 / 8,900 BTU/h, with power consumption of 3,500 / 2,897 W and current of 15.3 / 13.7 A.
The difference is significant: electric heating consumes practically as much electricity as the heat it produces, whereas a heat pump moves heat from outdoors to indoors.
This PTAC is not a low-temperature heat pump rated for -25 °C or -30 °C
For the Montréal and Greater Montréal market, this point deserves particular attention.
The SENPT-12AEN documentation indicates an outdoor operating range of:
- cooling: 64 to 109 °F;
- heating: 23 to 76 °F.
The manufacturer also specifies a charge of 26.81 oz of R32.
In other words, the published lower operating limit in heating mode is approximately 23 °F, which is slightly below the freezing point.
We therefore would not present this model as equivalent to a cold-climate wall-mounted heat pump that can maintain heating at -25 °C or -30 °C.
In a Montréal building, the overall heating system must be planned accordingly. The PTAC does include an electric element, but a homeowner replacing a primary heating system must have the following properly assessed:
- the room's heating load;
- wall insulation;
- the windows;
- wind exposure;
- the floor area;
- the existing heating system;
- the needs during periods of intense cold.
This is exactly the kind of detail that prevents selecting equipment solely because the label says “heat pump.”
438 CFM: why airflow matters as much as BTUs
The indoor airflow reaches 438 CFM at high speed and 344 CFM at low speed.
CFM, or cubic feet per minute, indicates the volume of air moved by the fan.
For a PTAC, adequate airflow helps to:
- distribute cool air more quickly throughout a room;
- reduce temperature differences between two zones;
- improve heat transfer across the heat exchanger;
- limit excessively short cycles when the installation is properly sized;
- maintain acceptable air circulation in relatively long rooms.
However, more CFM does not automatically mean greater comfort.
The PTAC’s position is decisive. If a unit is installed behind a sofa, bed, piece of furniture, or thick curtain, some of the airflow may be short-circuited. The cool or warm air then returns too quickly to the unit’s intake without actually treating the entire room.
This is a problem we seek to eliminate during the planning stage.
Sound level: 51.5 to 52 dB(A) indoors
A PTAC has its compressor in the same housing as the indoor unit. Therefore, it cannot be directly compared with the sound level of a wall-mounted unit whose compressor is located outside.
For the SENPT-12AEN, Senville indicates:
- 51.5 dB(A) at low speed;
- 52 dB(A) at high speed;
- 67 dB(A) on the outdoor side.
The difference of only 0.5 dB between the two indoor speeds also shows that the total noise does not come solely from the fan. The mechanical assembly contributes to the sound level.
In a hotel room, studio apartment, or bedroom, we always consider the location of the bed and the distance between the occupant and the PTAC. Two installations with exactly the same unit can create a very different perception of sound simply because of the room layout.
R32: important information for a new generation of PTACs
The SENVILLE SENPT-12AEN operates with R32 refrigerant.
The documentation indicates a charge of 26.81 oz.
For the owner, this mainly means that installation, diagnostics, and any necessary repairs must be carried out using tools and procedures appropriate for the refrigerant used.
R32 belongs to the class of mildly flammable refrigerants. This does not make the unit problematic in a compliant installation, but it requires following the appropriate technical procedures when servicing the refrigeration circuit.
Since the PTAC is a factory-precharged self-contained unit, a standard installation does not require connecting a copper lineset as with a wall-mounted heat pump.
This is one of the practical advantages of the PTAC format.
Installing a SENVILLE 12,000 BTU PTAC in Quebec: the details that really determine the outcome
Replacement in an existing PTAC opening: the most advantageous scenario
The SENPT-12AEN uses a standard PTAC format, and Senville indicates compatibility with standard PTAC wall openings. For a new installation, the wall sleeve and exterior grille are sold separately.
This information changes a lot of things on a job site.
When replacing a unit in an existing hotel or building, we check the following before ordering:
- the exact dimensions of the existing unit;
- the sleeve’s width and height;
- the wall depth;
- the condition of the exterior grille;
- the slope of the casing;
- air infiltration around the opening;
- the existing electrical supply;
- the space in front of the air intakes and outlets.
The SENPT-12AEN measures 42.01 in. wide × 20.91 in. deep × 15.98 in. high and weighs approximately 110.23 lb net.
Even when an opening appears standard, a few millimeters or a deformation in an old sleeve can complicate the replacement.
A proper installation must also prevent water infiltration, drafts, and vibrations transmitted to the wall.
Replacing a PTAC is not simply a matter of “removing the old one and sliding in the new one”
This is a common mistake in buildings where PTACs have been installed for fifteen or twenty years.
An old casing may have:
- corrosion;
- a partially blocked exterior grille;
- a deformed sleeve;
- deteriorated sealing joints;
- an incorrect slope;
- an unsuitable electrical outlet;
- an opening that is too large;
- a poorly insulated interior finish.
Reusing these components without inspection can negate some of the benefits of the new unit.
For example, an opening that continuously lets in cold air at -15 °C will increase the room’s heating needs even if the PTAC is working perfectly.
At AirGreen, we therefore consider the enclosure around the PTAC to be part of the HVAC installation, not merely a finishing detail.
208/230 V power supply and 20 A outlet: verify before installation
The Senville SENPT-12AEN operates on 208/230 V single-phase at 60 Hz and has a 20 A outlet with integrated reset protection.
This feature is particularly important when replacing an older unit.
Cooling mode requires relatively little current, but electric heating can reach 15.3 A, depending on the voltage. Therefore, you should never rely solely on the compressor’s power consumption to determine whether the existing power supply is suitable.
Before installation, we verify the actual electrical configuration.
In a building with several dozen PTACs, this question becomes even more important: multiple 3.5 kW electric heating elements operating simultaneously represent a considerable load for the building’s electrical system.
PTAC or ductless heat pump: the two solutions meet different needs
For a single-family home in Laval, Longueuil, or on the South Shore, a cold-climate ductless heat pump will often be more appealing when efficient heating during the Quebec winter is the goal.
A SENVILLE PTAC, however, becomes highly relevant when the objective is different.
It is particularly well suited to:
- a hotel room;
- an apartment requiring independent control;
- a multi-unit residence;
- a studio apartment;
- a room that already has a PTAC opening;
- a building where installing refrigerant lines would be difficult;
- a quick replacement of an existing terminal unit.
In these situations, its self-contained design greatly simplifies the installation.
A typical scenario we analyze at AirGreen
Let’s consider an apartment in a Montreal building where an old 12,000 BTU PTAC needs to be replaced.
The room is a reasonable size for this capacity, but the owner also wants to use the new unit for heating.
We do not stop at the 12,000 BTU capacity.
We first check whether the existing opening is truly compatible. Then, we confirm the 208/230 V and 20 A circuit. We inspect the condition of the exterior grille and the wall’s watertightness.
We then explain to the owner that the SENPT-12AEN provides approximately 10,800 BTU/h in heat pump mode, but that the published heating range ends at 23 °F. For Montreal’s climate, it is therefore necessary to anticipate how the building will behave below this temperature and understand the role of electric heating.
This conversation avoids unrealistic expectations: buying a heat pump does not automatically mean getting a heat pump designed to operate at -30 °C.
This is precisely why we prefer to review the complete technical data sheet before approving a unit.
Maintenance of the SENPT-12AEN PTAC
A PTAC must be serviced regularly, particularly in rental buildings and hotels where it operates for several hours a day.
We particularly recommend monitoring:
- the air filter;
- the indoor heat exchanger;
- the outdoor heat exchanger;
- air intakes and outlets;
- the outdoor grille;
- dust accumulation;
- signs of water or condensation;
- vibrations;
- abnormal changes in noise;
- heating and cooling capacity.
A heavily soiled filter reduces airflow and may prevent the unit from properly delivering its available 438 CFM at high speed.
A blocked outdoor heat exchanger causes another problem: since the condenser is integrated directly behind the wall, leaves, debris, or a blocked grille can hinder heat rejection.
Three signs that should prompt a technical inspection
The PTAC runs for a long time without reaching the set temperature
This may be caused by a clogged filter, a dirty heat exchanger, a loss of cooling capacity, or simply a unit that is too small for the actual load.
The air is warm, but the electricity bill is increasing sharply
It is necessary to determine whether the unit is still heating primarily through the heat pump or whether the 3.5 kW electric element is operating much more often.
This distinction is particularly important in our climate.
The noise or vibrations have increased
A PTAC weighing more than 110 lb installed in a poorly supported sleeve can transmit vibrations to the wall. An inspection can distinguish a mechanical problem from a support or installation problem.
Which customers would AirGreen recommend the SENVILLE 12,000 BTU to?
We consider this model particularly interesting when a customer is looking for:
- an 12,000 BTU R32 PTAC;
- a packaged solution;
- a replacement for an old standard PTAC;
- a unit capable of cooling and heating;
- an integrated electric heating system;
- a system powered by 208/230 V;
- local control via remote control or digital panel;
- a solution suited to a hotel, apartment, or residence.
However, when a customer is primarily looking for main heating at very low temperatures, we compare this PTAC with cold-climate heat pumps better suited to Montréal winters.
Our role is not to force one technology into every application. The right system is the one that matches the building, its use, and the actual operating conditions.
Why have your PTAC installed or replaced by AirGreen
At AirGreen, we serve Montréal, Laval, Longueuil, the South Shore, the North Shore, and the Greater Montréal area for air conditioning, heating, heat pumps, and HVAC solutions.
For a project involving the SENVILLE SENPT-12AEN PTAC, we can specifically check:
- compatibility with the wall opening;
- the sleeve dimensions;
- the outdoor grille;
- the electrical supply;
- required capacity;
- winter operating conditions;
- the condition of the existing installation;
- control requirements;
- access for future maintenance.
This approach avoids choosing a PTAC solely based on price or BTU capacity.
The SENVILLE SENPT-12AEN offers an interesting combination: 12,000 BTU cooling capacity, heat pump, 3.5 kW electric heating element, R32, maximum airflow of 438 CFM, and 208/230 V power supply. The official documentation also confirms its standard PTAC format and the main electrical, acoustic, and dimensional parameters.
Its main advantage is its simplicity as a self-contained terminal unit. Its main limitation in the Quebec context is that its heat-pump heating range does not match that of a cold-climate heat pump designed to operate at -25 °C or -30 °C.
This is the difference we take into consideration before making every recommendation.
Request a quote for your SENVILLE PTAC
Do you need to replace an old PTAC in an apartment, hotel, residence, or commercial building? Contact AirGreen for an assessment and quote. We can confirm whether the SENVILLE SENPT-12AEN 12,000 BTU R32 is truly suitable for your installation in Montréal, Laval, Longueuil, the South Shore, or the North Shore and check the technical details before ordering and installation.