BRADFORD WHITE M3ST200R5A Hot Water Storage Tank (200 gallons) | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: M3ST200R5A
757 L200 US gal of storage
5 yrstank warranty
Talk to an expert · 514 316-2973
5-year tank warranty, 1-year parts2 1/2 in NPT connections
01 · Why this model

What sets the Bradford White M3ST200R5A apart

633 lb

Shipping weight

Bradford White sheet C407 lists an approximate shipping weight of 633 lb for the M-3-ST200R5A.

2 1/2 in NPT

Water connections

Water connections are 2 1/2 in NPT (front and top).

180 °F

Storage up to 82 °C

The tank is designed to store potable water up to 180 °F (82 °C) at 150 psi working pressure.

ASME

ASME standard

The M-3-ST200R5A comes standard with ASME construction.

02 · How it works

A hot water reserve, not a water heater

Heating applianceboiler or water heaterhot waterreturnTo the fixturesStoragehot waterstays on top
  1. A boiler or a water heater heats the water.
  2. A pump circulates it to the tank, which keeps it hot.
  3. At peak times the reserve adds to production: more hot water available at once.
03 · Will it fit?

Check the height and the way in before our visit

It travels upright. Measure the ceiling at the spot and the narrowest door on the way.

in
in

Unit: 77 in tall (1956 mm), 32 in across (813 mm), about 633 lb shipping weight. The clearances the manufacturer requires are checked on site.

04 · Your current tank

How old is yours?

The year it was made is on the tank’s rating plate. Enter it.

Signs it is wearing out

  • Hot water runs out sooner than it used to.
  • The water comes out slightly reddish.
  • Rust shows at the bottom of the tank.
  • Moisture or drips around the unit.

Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.

05 · Installation

What the spot needs, and who does what

A heat sourceA boiler or water heater sized for the demand, with its circulation pump.
2 1/2 in NPT waterCold inlet, hot outlet and an accessible shut-off valve.
T&P valveTemperature and pressure relief valve, with its discharge line.
Pan and detectorDrip pan under the tank and a leak detector: strongly recommended (CAA-Québec).

AirGreenFree visit and quote, coordination of the work.

HeatingBoiler connection by a hydronic heating contractor (RBQ 15.4).

PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).

YouA photo of the rating plate, the spot and the stairs saves us a trip.

06 · Maintenance

A few habits that make it last

  1. Start-up daySetting the temperature, with you.
  2. Every yearPartial drain to flush sediment, and a test of the relief valve.
  3. Depending on your waterAnode inspection: it wears so the tank steel does not. In hard water it goes faster.
07 · Spec sheet

Every figure, with its source

Capacity and performance
Model
M3ST200R5A
Capacity
200 US gal · 757 L
Dimensions and connections
Height
77 in · 1,956 mm
Diameter
32 in · 813 mm
Shipping weight (approx.)
633 lb · 287 kg
Water connections
2 1/2 in NPT (front and top)
Build and warranty
Inner lining
Vitraglas with Microban
Drain valve
Brass
Limited warranty, tank
5 years
Limited warranty, parts
1 year

Manufacturer data. Detailed sources at the bottom of the page.

08 · Same family

The size below and above

119 US gal62.5 in tallSee the smaller one
200 US gal77.0 in tallYou are here
09 · Questions

What people ask us most

Is there a LogisVert grant for this water heater?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.

What is a storage tank for?

It does not heat water itself. It holds water heated by a boiler or a water heater, to meet the big peak demands of a business or a building.

Who does the installation?

AirGreen does the visit and the quote and coordinates the work. The water connections are done by a master pipe-mechanic (CMMTQ).

10 · AirGreen

We check the spot before we sell you anything

Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.

Book my free estimate
Sources checked November 2, 2026.
  1. Bradford White M-3 Storage Tank spec sheet C407-0526 CANADA · cdn.shopify.com
  2. Québec.ca, “Eau chaude”, updated November 5, 2025 (186 L/day, 7 °C water, 60 °C, volumes per use).
  3. Québec Construction Code, Chapter III Plumbing, art. 2.2.10.7 (RBQ).
  4. CAA-Québec, “Chauffe-eau: quelle capacité choisir”, updated June 29, 2026.
  5. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.

Costs shown are indicative estimates before tax.

A 200 US gallon tank in ASME configuration for buildings that use a lot of hot water

Some buildings cannot afford to run out of hot water, even for a few minutes. A seniors’ residence during morning care, a sports centre whose showers fill up after every game, a commercial laundry or a hotel in high season. For these uses, the Bradford White M3ST200R5A hot water storage tank offers a reserve of 200 US gallons (167 imperial gallons, or 751 L) and includes the ASME configuration. AirGreen installs it in commercial and institutional buildings in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.

Like any storage tank, the M3ST200R5A does not heat water. It holds the water produced by commercial electric water heaters or by an electric boiler, and makes it available when demand exceeds what these units produce at that moment.

What the ASME configuration changes

The American Society of Mechanical Engineers (ASME) code governs the design and construction of pressure vessels. In Bradford White’s storage tank series, ASME construction is offered as an option, and the M3ST200R5A is precisely the version that includes it. In many projects, the engineer, the insurer or the building manager requires a tank built to this code above a certain volume; choosing the ASME version from the outset avoids reordering at the last minute. We confirm this requirement with you from the assessment stage.

Manufacturer’s data

  • Capacity: 200 US gallons / 167 imperial gallons / 751 L
  • Construction: ASME configuration included
  • Working pressure: 150 psi (1,034 kPa)
  • Water connections: 2 1/2 in (64 mm) NPT
  • Inner lining: Vitraglas with Microban
  • Insulation: 2 in (51 mm) CFC-free foam on the sides and top
  • Protection: two anode rods
  • Drain valve: brass, low-restriction, vandal-resistant design
  • Dimensions: height 77 in (1,956 mm), diameter 32 in (813 mm)
  • Weight: 633 lb (287 kg)
  • Standard: meets or exceeds ASHRAE 90.1b

Buildings where this volume makes sense

A 200 US gallon reserve is justified when demand arrives in very sharp waves. In a seniors’ residence, baths and care are concentrated in the morning. In an arena or a fitness centre, all the showers run at the same time for twenty minutes, then nothing. A commercial laundry fills several washers at once. A small hotel or inn sees its guests shower at the same hour before checkout.

In a medium-sized residential building, this volume is sometimes larger than needed; a smaller tank from the same series may be enough. It is the analysis of your peaks that decides, not the size of the building.

A volume that changes the system design

With large storage, hot water production can be spread over long hours rather than concentrated at the peak. In practice, this often makes it possible to use electric water heaters or an electric boiler of reasonable wattage relative to the building’s electrical service, while still delivering the peak without a temperature drop. A circulating pump, controlled by a thermostat on the tank, handles the exchange between the heating units and the reserve. A thermostatic mixing valve at the outlet keeps the stored water hot while delivering a safe temperature to showers and sinks.

Planning the delivery of a 633 lb tank

The M3ST200R5A weighs 633 lb empty. Once filled, the load on the floor becomes considerable, and the slab must be able to carry it. Its 32 in diameter does not fit through every door, and its 77 in height requires checking the free height under the pipes and ducts of the mechanical room. We plan the delivery route, the handling equipment and the final position before ordering, taking into account the service space around the fittings and the drain valve.

Tank construction and protection

The inside is lined with Vitraglas with Microban and protected by two anode rods. On a tank this tall, two anodes spread the protection better than one. 2 in of CFC-free foam covers the sides and top, and Bradford White states that its storage tanks meet or exceed the ASHRAE 90.1b standard.

2 1/2 in connections and working pressure

The 2 1/2 in (64 mm) NPT water connections allow high flow rates to the building’s distribution system. The working pressure is 150 psi (1,034 kPa). We check the supply pressure, install a pressure-reducing valve when needed, and select a relief valve suited to the volume and configuration of the tank. A thermal expansion tank sized for the system completes the installation.

Maintaining a large tank

One visit per year is a minimum for a tank of this volume: flushing sediment through the low-restriction brass valve, testing the relief valve, checking the fittings and the pump controls, and inspecting the anodes at regular intervals. In a building where hot water is essential, we schedule these visits outside peak hours.

Manufacturer’s warranty

Bradford White provides a 5-year limited tank warranty and a 1-year limited parts warranty.

Installation of the Bradford White M3ST200R5A tank by AirGreen

AirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. For a tank of this size, our work includes:

  • analysis of consumption peaks and of the electric heating units in place;
  • confirmation of the ASME requirement and of the floor’s load capacity;
  • planning of delivery, handling and positioning;
  • removal of old tanks or the equipment being replaced;
  • 2 1/2 in water connections, the circulation loop and isolation valves;
  • the relief valve, its discharge pipe, the expansion tank and the thermostatic mixing valve;
  • the electrical connection of the pump and its control, commissioning and a yearly maintenance plan.

We work with property managers, institutions and businesses in Montreal, Laval, Longueuil, Brossard, Boucherville, Saint-Eustache, Terrebonne, Mascouche and across the South Shore and the North Shore. The on-site estimate is free, the quote is written and financing is available.

Request your free quote for the Bradford White M3ST200R5A tank. Send us photos of your mechanical room and the list of your current units: we will get back to you with a complete, priced configuration.