The Arcoaire EVD4X30M17A 2.5-ton R-410A cased coil sits on your furnace and, matched with a Arcoaire outdoor air conditioner, cools the whole home through the existing ductwork.
Model numberEVD4X30M17A
514 316-2973 · sales@airgreen.ca
Quick facts
EVD4X30M17A: 2.5 tons and the first 17-1/2 in cabinet in the Arcoaire series
In Arcoaire's EVD4X series, there is a boundary that many homeowners do not notice until the visit: the width of the cabinet. The two smallest models measure 14-3/16 in. Starting with the EVD4X30M17A evaporator coil, the width goes up to 17-1/2 in. It is also the first model to offer 2.5 tons (30,000 BTU/h), a mid-range size that suits the medium-sized home, from the two-storey house to the bungalow with a basement.
We install it on furnaces in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
What kind of home is this model made for?
Picture a two-storey house with a well-insulated upper floor, or a bungalow whose basement stays cool in summer without help. In these homes, the cooling load is higher than in a small unit, without reaching that of a large residence. The 2.5 ton size fills that middle ground.
We never pick the size by eye. We calculate the load, then compare it with the available options. Sometimes the result falls between two sizes: we then explain which one is the safer choice for the home and why.
What the 17-1/2 in width means
The cabinet is 17-1/2 in wide, 19-7/16 in high and 20.6 in deep, and weighs 31.2 lb net. These dimensions need to be checked against your furnace before any order. If the furnace is narrower, we build an insulated transition on site. If it is exactly the right width, the installation is direct and the seal is excellent.
The coil sits in a vertical position, upflow or downflow. It comes in its insulated cabinet, which avoids assembling parts inside a tight plenum.
Inside: V shape, TXV and condensate
The two faces of the coil form a V: you gain heat exchange surface in a compact volume. The TXV metering device regulates the flow of R-410A entering the tubes. The connections are 3/8 in on the liquid side and 3/4 in on the suction side.
Condensation water falls into a sloped PBT pan fitted with 3 sealed plugs; the exact drain diameter is not published by the manufacturer, so we take it on site when we make the connection.
How the air becomes cool
- The outdoor unit sends the refrigerant to the coil.
- In the tubes, it evaporates and picks up the heat from the air.
- The furnace blower pushes the cooled air through your ducts.
- Moisture condenses on the coil and goes to the drain.
- In winter, the system is off and the furnace heats on its own.
The manufacturer reserves this coil for cooling. It pairs with an air conditioner, not a heat pump.
Placing it in the EVD4X series
Here is how this model compares with the six others, only on the published points:
- EVD4X18M14A (1.5 ton) and EVD4X24M14A (2 tons): 14-3/16 in cabinet, for narrower furnaces and more modest loads.
- EVD4X36M17A (3 tons) and EVD4X42M17A (3.5 tons): the same 17-1/2 in width as this one, with higher capacities.
- EVD4X48M24A (4 tons) and EVD4X60M24A (5 tons): 24-1/2 in cabinet, for large homes.
In other words, if your furnace is 17-1/2 in, this model is the entry point for that width: you can move up in capacity without changing the footprint. And if it is narrower but the load calls for 2.5 tons, a custom transition settles the question.
Matching and AHRI number
A coil has no SEER2 or EER2 rating of its own. These figures belong to the system, that is, a coil and an Arcoaire outdoor unit of the same capacity and the same refrigerant, linked by an AHRI number. We check that number before ordering, so that the ratings promised to you are the ones you get, and so that your comparison of quotes is fair.
Frequently asked questions
Can I keep my current air conditioner? Generally no: the coil runs on R-410A and must be paired with the outdoor unit intended by the manufacturer. We install the complete system.
Can this coil also heat? No. For a heat pump, we offer a coil approved for that use.
Is the furnace still useful? Yes: its blower pushes the cool air in summer and it keeps heating the house in winter.
Our work, from the first survey to commissioning
- survey of the furnace, the blower and the electrical panel;
- coil set in the plenum, tight joints, custom transition if needed;
- outdoor unit on a pad or bracket, brazed piping, nitrogen test, evacuation;
- condensate drain and thermostat connected;
- airflow adjustment and demonstration.
AirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01.
Points to confirm before choosing
- R-410A: the outdoor unit must use the same refrigerant.
- The 17-1/2 in width: we compare it with the furnace during the visit.
- The blower: it must deliver the airflow the system requires.
Incentives
Hydro-Québec programs target heat pumps. This coil, reserved for cooling, does not qualify; eligibility depends on the complete system and the installation date. If this matters to you, we present an eligible heat pump in the same quote.
About Arcoaire
A brand of International Comfort Products, a Carrier subsidiary, Arcoaire is distributed in Quebec by Tecnico. Its QuietComfort DLCURAH heat pump with an Inverter compressor goes with the DL coil; the EVD4X cased V-coil series, for its part, handles air conditioning on a furnace.
An example of a visit
Take a suburban two-storey house whose upper floor is hot enough that people sleep in the basement in July. We start with the plenum: width, condition of the seal, access for the blower. Then we move on to the electrical panel and the possible location of the outdoor unit, away from bedroom windows to limit noise.
At the end of the visit, you receive a written quote that states the coil model, the planned match and any related work. Nothing is hidden in a vague line: if a duct transition is needed, it appears.
Noise, appearance and the yard
A single outdoor unit replaces several window units. It is installed on a pad or bracket, away from resting areas, and stays out of sight if it is placed with a little thought. Inside, there is nothing to see: the coil is in the plenum, and the existing vents distribute the air. It is a gain in looks as much as in sound.
Get your quote
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Arcoaire system. Financing is available to spread the cost of the project.
The cooling coil for your furnace
The EVD4X30M17A sits in the plenum of a furnace. Connected to an outdoor air conditioner, it cools in summer; the furnace keeps heating in winter.
- Adding central air conditioning to a furnace
- Replacing an old central air conditioner
- Replacing window air conditioners
- Keeping the furnace for all the heating
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-410A refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Explore the range
Evaporator coilsSee allSame brand
ARCOAIRESee all
Frequently asked questions
Can this coil heat?
No. The manufacturer limits it to air conditioning: it is matched with an air conditioner, not a heat pump. For heat pump heating we offer a coil approved for that use.
Can I keep my current air conditioner?
Usually not. The coil runs on R-410A and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. Its blower moves the cool air in summer and it keeps heating the home in winter.
A 2.5-ton Arcoaire coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.