ARCOAIRE EVD4X36M17A Evaporator V-Coil | 3 Tons

In stock

The Arcoaire EVD4X36M17A 3-ton R-410A cased coil sits on your furnace and, matched with a Arcoaire outdoor air conditioner, cools the whole home through the existing ductwork.

Model numberEVD4X36M17A

3 tons36,000 BTU/h nominal
17-1/2 inwidth
R-410Arefrigerant
R-410ACentral air conditioningCasedR-410A
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEVD4X36M17A
ManufacturerArcoaire
Size3 tons
Width17-1/2 in
RefrigerantR-410A
MeteringTXV

Arcoaire EVD4X36M17A 3 ton coil: turning the bungalow furnace into a central air conditioner

On a July afternoon, the basement is cool, but the upper floor feels like an oven. Fans stir warm air, a window air conditioner hums in the main bedroom, and the furnace sits there doing nothing. It is a very familiar scenario in the bungalows and two-storey homes of Montreal, Laval, Longueuil, the North Shore and the South Shore. The 3 ton (36,000 BTU/h) Arcoaire EVD4X36M17A evaporator coil puts that furnace to work all year long.

What this coil does, without jargon

Imagine a large radiator working in reverse, placed in the furnace's air duct. Instead of warming, it cools: R-410A refrigerant flows through it, absorbs the heat from the air, then returns outside where the outdoor unit gets rid of it. The blower already in place sends the cooled air to each vent, through the home's existing ducts, with no new openings cut.

The manufacturer intends this coil for central air conditioning. It pairs with an outdoor air conditioner, not a heat pump.

The dimensions to remember

  • width: 17-1/2 in;
  • height: 19-7/16 in;
  • depth: 20.6 in;
  • net weight: 31.2 lb;
  • positions: vertical, upflow or downflow.

The 17-1/2 in width must match the width of the furnace. If it does not, we build an insulated transition on site, which prevents air leaks and keeps the airflow steady.

A size halfway between medium and large

At 3 tons, we are in the territory of the good-sized bungalow and the two-storey house. Often the home already has an old central air conditioner at the end of its life or, failing that, a few window units. Replacing it all with a single system gives more even comfort and frees up the windows.

As always, this choice comes from a load calculation, not a rough rule. We take into account the insulation, the windows, the number of floors and the condition of the ducts.

Under the hood: TXV, connections, condensate

The metering device is a TXV: a valve that adjusts the refrigerant flow according to the heat to be removed. The coil connects with a 3/8 in liquid line and a 3/4 in suction line. The condensate pan is sloped PBT, with 3 sealed plugs; the drain diameter is not published, so we confirm it at installation.

Why the efficiency rating does not appear on the spec sheet

Many people are surprised not to find any SEER2 on a coil's page. That is normal: efficiency is measured on a complete system. The AHRI number links a specific coil to a specific outdoor unit, and it is this number that the incentive programs also use. We confirm it in the directory before ordering.

Where does the 3 ton sit in the series?

To help you decide, here are the reference points of the EVD4X series, all R-410A, all with a TXV and a V-coil cabinet:

  • EVD4X18M14A, 1.5 ton, and EVD4X24M14A, 2 tons: 14-3/16 in width.
  • EVD4X30M17A, 2.5 tons: the same 17-1/2 in width as the 3 ton, with one step less capacity.
  • EVD4X42M17A, 3.5 tons: still 17-1/2 in, with one step more.
  • EVD4X48M24A, 4 tons, and EVD4X60M24A, 5 tons: 24-1/2 in width.

What this means for you: if your furnace measures 17-1/2 in, you stay in the same footprint for three capacities. We choose the one the calculation justifies, not the biggest one by reflex.

What changes in the home in summer

Window units cool one room, block the view and leave the others hot. A central system distributes cool air everywhere, with a single discreet outdoor unit. It also removes humidity, which matters when the heat is heavy and sticky.

The thermostat controls the furnace and the air conditioner: one device to set, winter and summer. If you also want to heat with a heat pump, you will need a different coil, approved for that use, and we compare the two routes in the quote.

Do you also need to replace the outdoor unit?

Generally yes. The coil must be paired with the outdoor unit intended by the manufacturer, with the same refrigerant and the same capacity. Keeping an old air conditioner does not give you a certified system and compromises the ratings. We therefore install the complete system.

What our installation includes

  • measuring the furnace, checking the blower and the electrical panel;
  • installation in the plenum, custom transition if necessary, sealed duct connections;
  • outdoor unit on a pad or bracket, brazed piping, nitrogen pressure test, evacuation;
  • connection of the condensate drain and the thermostat;
  • commissioning, airflow adjustment and explanations.

We are a family-owned heating and cooling company, based in Montreal for more than fifteen years; our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01.

Checks before deciding

  • Refrigerant: R-410A, to be paired with an outdoor unit that matches on this point.
  • The published ratings apply to the matched system, not to the coil alone.
  • The furnace must have the right width and a suitable blower; we confirm at the visit.

Financial help

Hydro-Québec programs target heat pumps. A coil reserved for cooling does not qualify, and eligibility always depends on the complete system and the installation date. If financial help figures in your budget, we present an eligible heat pump in the same quote.

Who is Arcoaire?

Arcoaire is a brand of International Comfort Products, a Carrier subsidiary, distributed by Tecnico in Quebec. The QuietComfort DLCURAH heat pump with an Inverter compressor pairs with the DL coil, and the EVD4X cased V-coil series serves air conditioning on a furnace.

Small habits that extend the life of the system

Change the furnace filter regularly, clear the return air grilles behind furniture, and keep the outdoor unit free of leaves and branches. These steps cost almost nothing and protect the coil, the blower and the compressor.

Every spring, before starting the season, check that the water drains properly through the drain after a first period of operation. If it does not, a quick fix avoids water damage to the basement ceiling.

A quote you can compare

When a contractor gives you an offer for central air conditioning, ask for the exact model of the coil, that of the outdoor unit and the AHRI number of the match. With us, these three pieces of information appear on the written quote. They let you check the ratings in the directory and compare two proposals on an identical basis, without being guided by a single overall price.

On to the estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Arcoaire system. Financing is available to spread the cost of the project.

01 · What it is for

The cooling coil for your furnace

The EVD4X36M17A sits in the plenum of a furnace. Connected to an outdoor air conditioner, it cools in summer; the furnace keeps heating in winter.

  • Adding central air conditioning to a furnace
  • Replacing an old central air conditioner
  • Replacing window air conditioners
  • Keeping the furnace for all the heating
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-410A refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerArcoaire
ModelEVD4X36M17A
TypeCased evaporator coil
LineEVD4X
Nominal size3 tons (36,000 BTU/h)
RefrigerantR-410A
Metering deviceTXV
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D17-1/2 × 19-7/16 × 20.6 in
Net weight31.2 lb
Model numberEVD4X36M17A
03 · Before installing

What to know before installing

  • R-410A refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
ARCOAIRE
See all
05 · Questions

Frequently asked questions

Can this coil heat?

No. The manufacturer limits it to air conditioning: it is matched with an air conditioner, not a heat pump. For heat pump heating we offer a coil approved for that use.

Can I keep my current air conditioner?

Usually not. The coil runs on R-410A and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. Its blower moves the cool air in summer and it keeps heating the home in winter.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-ton Arcoaire coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.