-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
A coil is chosen with the condenser, then by the width of your furnace.
In the model, the code 14, 17, 21 or 24 points to a furnace width: 14-3/16, 17-1/2, 21 or 24-1/2 in. Pick the position, the width and the size: you see the coils on our site that go on that cabinet, and the ones listed for a heat pump.
Which coils fit your furnace cabinet?
The 41 coils on this page, all designed for R-410A, with a factory-installed expansion valve (TXV). Widths and positions come from the manufacturer’s documents.
Coil position
Furnace cabinet width
System size
Measure the width of your gas or oil furnace cabinet where the coil sits; we check it at the visit anyway. The sheets line these widths up with the manufacturer’s gas furnaces. Any work on a gas or oil furnace is done by a licensed partner.
Coils of this size for this cabinet: 2 uncased coils for its plenum.
Coils of this size for this cabinet: 1 cased coil that sits flush on this cabinet and 1 uncased coil for its plenum.
Coils of this size for this cabinet: 2 cased coils that sit flush on this cabinet and 1 uncased coil for its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
Coils of this size for this cabinet: 3 cased coils that sit flush on this cabinet.
Coil of this size for this cabinet: 1 cased coil that sits flush on this cabinet.
Coils of this size for this cabinet: 1 cased coil that sits flush on this cabinet and 1 uncased coil for its plenum.
Coil of this size for this cabinet: 1 cased coil that sits flush on this cabinet.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
Coils of this size for this cabinet: 1 cased coil that sits flush on this cabinet and 1 uncased coil for its plenum.
Coils of this size for this cabinet: 3 cased coils that sit flush on this cabinet and 2 uncased coils for its plenum.
Coils of this size for this cabinet: 2 cased coils that sit flush on this cabinet and 1 uncased coil for its plenum.
Coil of this size for this cabinet: 1 cased coil that sits flush on this cabinet.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
Coil of this size for this cabinet: 1 cased coil that sits flush on this cabinet.
Coils of this size for this cabinet: 1 cased coil that sits flush on this cabinet and 2 uncased coils for its plenum.
Coils of this size for this cabinet: 2 cased coils that sit flush on this cabinet and 2 uncased coils for its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
Coil of this size for this cabinet: 1 cased coil that sits flush on this cabinet.
Coils of this size for this cabinet: 2 cased coils that sit flush on this cabinet.
Coil of this size for this cabinet: 1 cased coil that sits flush on this cabinet.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
Coil of this size for this cabinet: 1 cased coil that sits flush on this cabinet.
Coils of this size for this cabinet: 2 cased coils that sit flush on this cabinet.
Coil of this size for this cabinet: 1 cased coil that sits flush on this cabinet.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
No coil of this size sits flush on this cabinet or slides into its plenum.
Coil of this size for this cabinet: 1 cased coil that sits flush on this cabinet.
The width code, sheet by sheet. “N” (END4X, ENA4X): 14 = 14-3/16, 17 = 17-1/2, 21 = 21 and 24 = 24-1/2 in, cabinets that line up with the manufacturer’s gas furnaces. EAA4X: the same furnace widths in its decoder; the coil itself measures 13 to 23-5/16 in, to fit inside the plenum. “V” (EVD4X, EVM4X): the decoder gives a nominal width (14 = 14 in, 325 mm; 24 = 24 in, 610 mm) and Table 2 the flush fit on 14-3/16 to 24-1/2 in, or on the next narrower furnace with an adapter. ENH4X: 17 = 17 in in the decoder, a 17-1/2 in cabinet in the dimension table.
EAA4X18L14A
Uncased “A”, vertical · 1.5 tons · code 14 · 13 in coil
Air conditioner or heat pump
See the product →EAA4X24L14A
Uncased “A”, vertical · 2 tons · code 14 · 13 in coil
Air conditioner or heat pump
See the product →EAA4X30L14A
Uncased “A”, vertical · 2.5 tons · code 14 · 13 in coil
Air conditioner or heat pump
See the product →EAA4X36L17A
Uncased “A”, vertical · 3 tons · code 17 · 16-5/16 in coil
Air conditioner or heat pump
See the product →EAA4X36L21A
Uncased “A”, vertical · 3 tons · code 21 · 19-13/16 in coil
Air conditioner or heat pump
See the product →EAA4X42L21A
Uncased “A”, vertical · 3.5 tons · code 21 · 19-13/16 in coil
Air conditioner or heat pump
See the product →EAA4X48L21A
Uncased “A”, vertical · 4 tons · code 21 · 19-13/16 in coil
Air conditioner or heat pump
See the product →EAA4X48L24A
Uncased “A”, vertical · 4 tons · code 24 · 23-5/16 in coil
Air conditioner or heat pump
See the product →EAA4X60L24A
Uncased “A”, vertical · 5 tons · code 24 · 23-5/16 in coil
Air conditioner or heat pump
See the product →END4X24L14A
Cased “N”, vertical · 2 tons · code 14
Heat pump: not stated in its sheet
See the product →END4X24L17A
Cased “N”, vertical · 2 tons · code 17
Heat pump: not stated in its sheet
See the product →END4X30L14A
Cased “N”, vertical · 2.5 tons · code 14
Heat pump: not stated in its sheet
See the product →END4X42L17A
Cased “N”, vertical · 3.5 tons · code 17
Heat pump: not stated in its sheet
See the product →END4X42L21A
Cased “N”, vertical · 3.5 tons · code 21
Heat pump: not stated in its sheet
See the product →END4X48L24A
Cased “N”, vertical · 4 tons · code 24
Heat pump: not stated in its sheet
See the product →END4X60L24A
Cased “N”, vertical · 5 tons · code 24
Heat pump: not stated in its sheet
See the product →ENA4X18L14A
Uncased “N”, in the plenum · 1.5 tons · code 14
Heat pump: not stated in its sheet
See the product →ENA4X42L21A
Uncased “N”, in the plenum · 3.5 tons · code 21
Heat pump: not stated in its sheet
See the product →ENA4X48L24A
Uncased “N”, in the plenum · 4 tons · code 24
Heat pump: not stated in its sheet
See the product →ENA4X60L24A
Uncased “N”, in the plenum · 5 tons · code 24
Heat pump: not stated in its sheet
See the product →EVD4X24M17A
Cased “V”, vertical · 2 tons · code 17
Air conditioner only
See the product →EVD4X24M17A
Cased “V”, vertical · 2 tons · code 17
Air conditioner only
See the product →EVD4X30M14A
Cased “V”, vertical · 2.5 tons · code 14
Air conditioner only
See the product →EVD4X36M21A
Cased “V”, vertical · 3 tons · code 21
Air conditioner only
See the product →EVD4X36M21A
Cased “V”, vertical · 3 tons · code 21
Air conditioner only
See the product →EVD4X42M21A
Cased “V”, vertical · 3.5 tons · code 21
Air conditioner only
See the product →EVD4X42M21A
Cased “V”, vertical · 3.5 tons · code 21
Air conditioner only
See the product →EVD4X42M24A
Cased “V”, vertical · 3.5 tons · code 24
Air conditioner only
See the product →EVD4X42M24A
Cased “V”, vertical · 3.5 tons · code 24
Air conditioner only
See the product →EVD4X48M21A
Cased “V”, vertical · 4 tons · code 21
Air conditioner only
See the product →EVD4X48M21A
Cased “V”, vertical · 4 tons · code 21
Air conditioner only
See the product →EVM4X24M17A
Cased “V”, multipoise · 2 tons · code 17
Air conditioner only
See the product →EVM4X24M17A
Cased “V”, multipoise · 2 tons · code 17
Air conditioner only
See the product →EVM4X30M17A
Cased “V”, multipoise · 2.5 tons · code 17
Air conditioner only
See the product →EVM4X30M17A
Cased “V”, multipoise · 2.5 tons · code 17
Air conditioner only
See the product →EVM4X36M17A
Cased “V”, multipoise · 3 tons · code 17
Air conditioner only
See the product →EVM4X36M17A
Cased “V”, multipoise · 3 tons · code 17
Air conditioner only
See the product →EVM4X42M21A
Cased “V”, multipoise · 3.5 tons · code 21
Air conditioner only
See the product →EVM4X42M21A
Cased “V”, multipoise · 3.5 tons · code 21
Air conditioner only
See the product →EVM4X48M21A
Cased “V”, multipoise · 4 tons · code 21
Air conditioner only
See the product →EVM4X48M21A
Cased “V”, multipoise · 4 tons · code 21
Air conditioner only
See the product →EVM4X60M21A
Cased “V”, multipoise · 5 tons · code 21
Air conditioner only
See the product →EVM4X60M21A
Cased “V”, multipoise · 5 tons · code 21
Air conditioner only
See the product →EVM4X60M24A
Cased “V”, multipoise · 5 tons · code 24
Air conditioner only
See the product →EVM4X60M24A
Cased “V”, multipoise · 5 tons · code 24
Air conditioner only
See the product →ENH4X30L17A
Cased “N”, horizontal · 2.5 tons · code 17
Heat pump: not stated in its sheet
See the product →ENH4X48L21A
Cased “N”, horizontal · 4 tons · code 21
Heat pump: not stated in its sheet
See the product →EHD4X24AAL
Slab, horizontal · 2 tons · width not published
Air conditioner or heat pump
See the product →EHD4X30AAL
Slab, horizontal · 2.5 tons · width not published
Air conditioner or heat pump
See the product →EHD4X36AAL
Slab, horizontal · 3 tons · width not published
Air conditioner or heat pump
See the product →EHD4X42AAL
Slab, horizontal · 3.5 tons · width not published
Air conditioner or heat pump
See the product →EHD4X48AAL
Slab, horizontal · 4 tons · width not published
Air conditioner or heat pump
See the product →EHD4X60AAL
Slab, horizontal · 5 tons · width not published
Air conditioner or heat pump
See the product →All 41 ARCOAIRE evaporator coils, right below.
Each product gives the model, the size, the width and the manufacturer’s document. The coil is chosen with the condenser or the heat pump, at the visit. Pricing by quote.
A, N, V or slab: the shape says where the coil goes.
The seven families on this page. A cased coil sits on the furnace cabinet; an uncased one slides into the plenum.
| Family | Position | Cabinet | Works with | On our site | Document | |
|---|---|---|---|---|---|---|
| Evaporator coils | ||||||
| EAA4X Uncased “A”, vertical | Vertical, in the plenum | No | Air conditioner or heat pump | 9 models 1.5 · 2 · 2.5 · 3 · 3.5 · 4 · 5 t · codes 14, 17, 21, 24 | 484 31 3904 02 02/2018 | |
| END4X Cased “N”, vertical | Vertical | Yes | Heat pump: not stated in its sheet | 7 models 2 · 2.5 · 3.5 · 4 · 5 t · codes 14, 17, 21, 24 | 484 31 3601 01 03/2014 | |
| ENA4X Uncased “N”, in the plenum | Vertical, in the plenum | No | Heat pump: not stated in its sheet | 4 models 1.5 · 3.5 · 4 · 5 t · codes 14, 21, 24 | 484 31 3601 01 03/2014 | |
| EVD4X Cased “V”, vertical | Vertical | Yes | Air conditioner only | 6 models 2 · 2.5 · 3 · 3.5 · 4 t · codes 14, 17, 21, 24 | EVD-ESD4X-31-02PD 06/22 | |
| EVM4X Cased “V”, multipoise | Vertical or horizontal | Yes | Air conditioner only | 7 models 2 · 2.5 · 3 · 3.5 · 4 · 5 t · codes 17, 21, 24 | EVM4X-31-01PD 11/22 | |
| ENH4X Cased “N”, horizontal | Horizontal, left or right | Yes | Heat pump: not stated in its sheet | 2 models 2.5 · 4 t · codes 17, 21 | ENH4X-31-01PD 12/21 | |
| EHD4X Slab, horizontal | Horizontal | Yes | Air conditioner or heat pump | 6 models 2 · 2.5 · 3 · 3.5 · 4 · 5 t | EV-003-AR-00 09/2022 | |
Air conditioner or heat pump: table of brochure EV-003-AR-00 (09/2022), p. 2, and EVD4X and EVM4X sheets, p. 1 (“AC applications only”). The “N” coil sheets (484 31 3601 01 and ENH4X-31-01PD) do not mention heat pumps. The EHD4X has no product data sheet in the documents we hold.
In the attic or the crawl space: three coils that lie flat.
When the furnace lies flat, in the attic or the crawl space, so does the coil.
ENH4X · horizontal “N”
Designed to fit a horizontal furnace, left or right side, and well suited to an attic or a crawl space. The coil slides out of the cabinet for service. Its sheet allows an R-410A or an R-22 system.
ENH4X-31-01PD, ed. 12/21, pp. 1 and 5EHD4X · horizontal slab
The brochure’s slab coil: horizontal only, cased, factory expansion valve, listed for an air conditioner or a heat pump. With no product data sheet, its dimensions are confirmed at the visit.
EV-003-AR-00, 09/2022, p. 2EVM4X · multipoise “V”
It installs upflow, downflow or horizontal, with five water-tight drain plugs (three vertical, two horizontal). For an air conditioner only.
EVM4X-31-01PD, ed. 11/22, p. 1Three things the coil sheets tell you.
The M in EVD4X36M21A stands for microchannel.
The “V” coils are made of flat aluminum refrigerant channels brazed to ridged aluminum fins, in a V, with the headers at the top.
EVD-ESD4X-31-02PD p. 2; EV-003-AR-00 p. 2The “N” cabinets meet 2 % air-leakage codes.
The sheet also calls them non-sweat, even in extreme conditions, with foil-faced insulation.
484 31 3601 01, 03/2014, p. 1A “V” coil comes out the front of its cabinet.
Once the door is off and the refrigerant lines are disconnected, it slides out without tools. It has no delta plate: both faces can be cleaned.
EVD-ESD4X-31-02PD p. 1; EVM4X-31-01PD p. 1What people ask us about coils.
A, N or V: what is the difference?
The shape. The “A” is the classic two-slab coil. The cased “N” is shorter than a comparable “A”. The microchannel “V” promises performance similar to an “A” in the size of an “N”. All the coils on this page have a factory-installed expansion valve.
I have a central heat pump: which coil?
Not a “V”: its sheets restrict it to air conditioners. The EAA4X “A” and the EHD4X slab are listed for either; for an “N”, we confirm it at the visit. On our add-on page, each system lists its coil and, when there is one, its AHRI number.
Cased or uncased?
A cased coil sits on the furnace, cabinet to cabinet. An uncased one (EAA4X, ENA4X) slides into the existing plenum: the ENA4X sheet says “plenum use only”, and the EAA4X sheet gives the width of the coil itself, 13 to 23-5/16 in.
My furnace is not one of these widths.
For the “V” coils, the manufacturer offers adapter kits with no offset, single offset or double offset (NAHB00101CA, NAHB00201CA, NAHB00301CA). For the others, a transition is made on site. We choose at the visit.
What if my system runs on R-22?
Among our coils, only the ENH4X sheet allows R-22. The “A”, vertical “N”, “V” and slab coils are R-410A; the EVD4X and EVM4X sheets say “R-410A refrigerant only”.
How do you choose the coil?
At the visit, with the condenser or the heat pump: the size, the cabinet width, the position and the pairing printed in the outdoor unit’s sheet.
Central air conditioner →
The condenser and the coil the manufacturer tested together.
Add-on to a furnace →
A heat pump and its coil, on your furnace.
Central heat pump →
Heat and cool: the coil is chosen with it.
The right coil, at the right width.
We measure your furnace cabinet, note the condenser or the heat pump, then choose a coil the manufacturer’s sheets allow. You get a quote with the exact models.
Sources checked on October 29, 2026
- ARCOAIRE, Evaporator Coils brochure EV-003-AR-00 (09/2022), pp. 1 and 2.
- ARCOAIRE, Expansion Valve Coils EAM4X, EAD4X, EAA4X, 484 31 3904 02 (February 13, 2018), pp. 1 and 2.
- ARCOAIRE, EVD4X, ESD4X Product Data, EVD-ESD4X-31-02PD (edition 06/22), pp. 1 to 3.
- ARCOAIRE, EVM4X Product Data, EVM4X-31-01PD (edition 11/22), pp. 1 to 3.
- Vertical Evaporator Coils END4X, ENW4X, ENA4X, 484 31 3601 01 (March 12, 2014), pp. 1 to 3.
- ARCOAIRE, ENH4X Product Data, ENH4X-31-01PD (edition 12/21), pp. 1 to 3 and 5.
- airgreen.ca product sheets (models, sizes and linked documents), re-read October 29, 2026.
Pricing by quote.
