ARCOAIRE EVM4X30M17A “V” Evaporator Coil | 2.5 Tons

In stock

The Arcoaire EVM4X30M17A multipoise coil: 2.5 tons of R-410A air conditioning in a 17-1/2 in cabinet, installed upflow, downflow or horizontal.

Model numberEVM4X30M17A

2.5 tons30,000 BTU/h nominal size
750-1,250CFM airflow range
33.7 lboperating weight (15.3 kg)
R-410AAir conditioning onlyMultipoiseAvailable while supplies last
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEVM4X30M17A
ManufacturerArcoaire
Size2.5 tons (30,000 BTU/h)
Width17-1/2 in (445 mm)
Airflow750 to 1,250 CFM
Connections3/8 in liquid · 3/4 in suction

The coil that follows your furnace, even when plans change

A basement being finished, a mechanical room being moved, a furnace laid in the ceiling to free up space: renovations often shake up where the heating system sits. The Arcoaire EVM4X30M17A multipoise evaporator coil keeps every option open. This 2.5-ton R-410A model installs in vertical upflow, vertical downflow or horizontal, and it connects to a 17-1/2 in electric furnace or air handler. We install it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.

What it does and who it is for

An evaporator coil is the indoor part of a central air conditioner. Set against the furnace, it receives refrigerant from the outdoor unit and cools the air the blower pushes through the ducts. The EVM4X30M17A is aimed at homes and units that need 2.5 tons of cooling, a capacity we confirm during the estimate. It pairs with an R-410A air conditioner, with 3/8 in connections for the liquid line and 3/4 in for the suction line. If the unit lies on its side, we take particular care with the condensate drain, which must keep a continuous slope.

How it is built

Arcoaire uses its Power-V design here, with the headers at the top and an all-aluminum microchannel coil; the manufacturer states it delivers the same or better SEER without a larger coil. The thermostatic expansion valve is factory installed. The condensate drain pan is PBT, a plastic that resists corrosion, and the 24-gauge pre-painted steel cabinet is fully insulated. The coil weighs 33.7 lb (15.3 kg) in operation.

Before choosing it, keep in mind that it is limited to air conditioning: Arcoaire states it does not pair with a heat pump. Sold alone, it does not qualify for the LogisVert grant. It is available while supplies last.

Installation, step by step

AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical).

  1. Free on-site estimate: position and width of the unit, condition of the ducts, outdoor air conditioner.
  2. Written quote specifying the chosen position and the work.
  3. Setting the coil, connecting it to the air ducts and the condensate drain.
  4. Brazing the refrigerant lines, leak testing and evacuation.
  5. Commissioning, with the blower set within the 750 to 1,250 CFM range published by the manufacturer.

Arcoaire offers a 10-year parts limited warranty when the unit is registered on time, and 5 years without registration within 90 days of installation.

Build air conditioning into your renovations

Tell us about your plans now: free estimate, written quote and financing to spread out the cost of the work.

01 · What it is for

A 2.5-ton coil for renovations

The EVM4X30M17A sits on a 17-1/2 in electric furnace or air handler, upright or on its side. It becomes the evaporator of a 2.5-ton R-410A central air conditioner.

  • Renovations where the heating unit changes location or orientation
  • Replacing a 2.5-ton coil, whatever its position
  • 17-1/2 in electric furnaces and air handlers
  • 2.5-ton R-410A central air conditioner
Three positionsVertical upflow, vertical downflow or horizontal: the same part suits all three orientations.
750 to 1,250 CFMThe airflow range of the performance table Arcoaire publishes for this model.
Insulated cabinet24-gauge pre-painted steel, foil-faced R-2.1 insulation, PBT condensate drain pan.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerArcoaire
TypeCased V evaporator coil (Power-V), multipoise
ConfigurationVertical upflow, vertical downflow or horizontal
Nominal size2.5 tons (30,000 BTU/h)
RefrigerantR-410A
Metering deviceThermostatic expansion valve (TXV), factory installed
Airflow (performance table)750 to 1,250 CFM
Liquid connection3/8 in
Suction connection3/4 in
Cabinet width (dimension B)17-1/2 in
Furnace for flush fit17-1/2 in (445 mm) wide
Other drawing dimensionsA 19-7/16 · C 15-3/4 · D 17-5/16 · E 15-11/16 · F 8-3/4 · J 14-1/2 in
Operating weight33.7 lb (15.3 kg)
Shipping weight40.0 lb (18.1 kg)
CoilAll aluminum (microchannel)
Condensate drain panPBT, corrosion resistant
Cabinet24-gauge pre-painted gray steel, fully insulated (R-2.1, foil faced)
ApplicationAir conditioning only
CertificationsUL and c-UL listed; AHRI rated
Manufacturer warrantyParts: 10 years with timely registration, 5 years if not registered within 90 days of installation
StandardsUL, c-UL
Model numberEVM4X30M17A
03 · Before installing

What to know before installing

  • Arcoaire limits this model to air conditioning: it does not pair with a heat pump.
  • Sold alone: not eligible for the LogisVert grant, and no efficiency rating of its own.
  • 3/8 in (liquid) and 3/4 in (suction) connections, for an R-410A air conditioner.
  • The flush fit is designed for a 17-1/2 in (445 mm) wide unit.
  • Available while supplies last.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
ARCOAIRE
See all
06 · Questions

Frequently asked questions

Why choose a multipoise coil?

Because it installs in vertical upflow, vertical downflow or horizontal. If the furnace changes location or orientation during renovations, the same coil follows.

Which air conditioner should it be paired with?

A 2.5-ton R-410A central air conditioner, connected with a 3/8 in liquid line and a 3/4 in suction line. We check the match before ordering.

What airflow does the blower need to deliver?

Arcoaire publishes this coil’s performance between 750 and 1,250 CFM. We set the blower within that range at commissioning.

Can it be used with a heat pump?

No. The manufacturer limits it to air conditioning. To heat with the outdoor unit, we offer a complete central heat pump.

What warranty does the manufacturer offer?

10 years on parts if the unit is registered on time, 5 years if it is not registered within 90 days of installation. Where the warranty cannot depend on registration, the 10-year period applies.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your 2.5-ton coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.