ARCOAIRE EVM4X30M17A “V” Evaporator Coil | 2.5 Tons
The Arcoaire EVM4X30M17A multipoise coil: 2.5 tons of R-410A air conditioning in a 17-1/2 in cabinet, installed upflow, downflow or horizontal.
Model numberEVM4X30M17A
514 316-2973 · sales@airgreen.ca
Quick facts
The coil that follows your furnace, even when plans change
A basement being finished, a mechanical room being moved, a furnace laid in the ceiling to free up space: renovations often shake up where the heating system sits. The Arcoaire EVM4X30M17A multipoise evaporator coil keeps every option open. This 2.5-ton R-410A model installs in vertical upflow, vertical downflow or horizontal, and it connects to a 17-1/2 in electric furnace or air handler. We install it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.
What it does and who it is for
An evaporator coil is the indoor part of a central air conditioner. Set against the furnace, it receives refrigerant from the outdoor unit and cools the air the blower pushes through the ducts. The EVM4X30M17A is aimed at homes and units that need 2.5 tons of cooling, a capacity we confirm during the estimate. It pairs with an R-410A air conditioner, with 3/8 in connections for the liquid line and 3/4 in for the suction line. If the unit lies on its side, we take particular care with the condensate drain, which must keep a continuous slope.
How it is built
Arcoaire uses its Power-V design here, with the headers at the top and an all-aluminum microchannel coil; the manufacturer states it delivers the same or better SEER without a larger coil. The thermostatic expansion valve is factory installed. The condensate drain pan is PBT, a plastic that resists corrosion, and the 24-gauge pre-painted steel cabinet is fully insulated. The coil weighs 33.7 lb (15.3 kg) in operation.
Before choosing it, keep in mind that it is limited to air conditioning: Arcoaire states it does not pair with a heat pump. Sold alone, it does not qualify for the LogisVert grant. It is available while supplies last.
Installation, step by step
AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical).
- Free on-site estimate: position and width of the unit, condition of the ducts, outdoor air conditioner.
- Written quote specifying the chosen position and the work.
- Setting the coil, connecting it to the air ducts and the condensate drain.
- Brazing the refrigerant lines, leak testing and evacuation.
- Commissioning, with the blower set within the 750 to 1,250 CFM range published by the manufacturer.
Arcoaire offers a 10-year parts limited warranty when the unit is registered on time, and 5 years without registration within 90 days of installation.
Build air conditioning into your renovations
Tell us about your plans now: free estimate, written quote and financing to spread out the cost of the work.
A 2.5-ton coil for renovations
The EVM4X30M17A sits on a 17-1/2 in electric furnace or air handler, upright or on its side. It becomes the evaporator of a 2.5-ton R-410A central air conditioner.
- Renovations where the heating unit changes location or orientation
- Replacing a 2.5-ton coil, whatever its position
- 17-1/2 in electric furnaces and air handlers
- 2.5-ton R-410A central air conditioner
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Arcoaire limits this model to air conditioning: it does not pair with a heat pump.
- Sold alone: not eligible for the LogisVert grant, and no efficiency rating of its own.
- 3/8 in (liquid) and 3/4 in (suction) connections, for an R-410A air conditioner.
- The flush fit is designed for a 17-1/2 in (445 mm) wide unit.
- Available while supplies last.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
ARCOAIRESee all
Frequently asked questions
Why choose a multipoise coil?
Because it installs in vertical upflow, vertical downflow or horizontal. If the furnace changes location or orientation during renovations, the same coil follows.
Which air conditioner should it be paired with?
A 2.5-ton R-410A central air conditioner, connected with a 3/8 in liquid line and a 3/4 in suction line. We check the match before ordering.
What airflow does the blower need to deliver?
Arcoaire publishes this coil’s performance between 750 and 1,250 CFM. We set the blower within that range at commissioning.
Can it be used with a heat pump?
No. The manufacturer limits it to air conditioning. To heat with the outdoor unit, we offer a complete central heat pump.
What warranty does the manufacturer offer?
10 years on parts if the unit is registered on time, 5 years if it is not registered within 90 days of installation. Where the warranty cannot depend on registration, the 10-year period applies.