ARCOAIRE EVM4X48M21A “V” Evaporator Coil | 4 Tons

In stock

The Arcoaire EVM4X48M21A multipoise coil: 4 tons of R-410A air conditioning in a 21 in cabinet, installed upflow, downflow or horizontal.

Model numberEVM4X48M21A

4 tons48,000 BTU/h nominal size
1,200-2,000CFM airflow range
3 positionsupflow, downflow, horizontal
R-410AAir conditioning onlyMultipoiseAvailable while supplies last
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEVM4X48M21A
ManufacturerArcoaire
Size4 tons (48,000 BTU/h)
Width21 in (533 mm)
Airflow1,200 to 2,000 CFM
Connections3/8 in liquid · 7/8 in suction
Operating weight38.2 lb (17.3 kg)

Large cooling capacity, whatever position your furnace is in

Large homes often have less conventional setups: an electric furnace lying in the ceiling of a finished basement, an air handler running downflow in a mechanical room, a duct system serving three levels. The Arcoaire EVM4X48M21A multipoise evaporator coil brings 4 tons of R-410A air conditioning to these systems, in vertical upflow, vertical downflow or horizontal. AirGreen installs it in Montreal, Laval, Longueuil and throughout the North Shore and the South Shore.

Which needs it serves

The 4-ton size is aimed at homes with high cooling demand. We only recommend it after assessing the house, because a coil that is too big for the need adds nothing. It lines up with a 21 in wide furnace or air handler and pairs with a 4-ton R-410A central air conditioner, with a 3/8 in liquid line and a 7/8 in suction line.

What the manufacturer built in

Arcoaire builds this V-coil on its Power-V design: the headers are at the top, and the manufacturer states it delivers the same or better SEER without resorting to a larger coil. The microchannel coil is all aluminum, the thermostatic expansion valve is factory installed, the PBT condensate drain pan resists corrosion and the 24-gauge pre-painted steel cabinet is fully insulated. The coil weighs 38.2 lb (17.3 kg) in operation.

The manufacturer publishes this model’s performance between 1,200 and 2,000 CFM. That is significant airflow: we check that the blower can deliver it and that the ducts can carry it. This coil is limited to air conditioning and does not pair with a heat pump. Sold alone, it does not qualify for the LogisVert grant. It is available while supplies last.

Our installation

AirGreen is a family business established in Montreal for more than fifteen years. Our ventilation, refrigeration and electrical work is done under RBQ licence 5645-9605-01. The installation includes:

  • a free on-site assessment of the house, the indoor unit and the ductwork;
  • setting the coil in the chosen position and sealing it to the ducts;
  • brazing the 3/8 in and 7/8 in lines, leak testing and evacuation;
  • connecting the condensate drain, with a continuous slope;
  • commissioning and setting the blower.

Arcoaire offers a 10-year parts limited warranty if the unit is registered on time, and 5 years if it is not registered within 90 days of installation.

Take the first step

Ask for your free estimate and receive a clear written quote. Our financing helps you spread out the cost of a system this size.

01 · What it is for

Four tons of cooling, in the position that fits

The EVM4X48M21A sits on a 21 in electric furnace or air handler, upright or on its side. Connected to a 4-ton R-410A central air conditioner, it cools a large home from a single duct system.

  • Large homes whose 21 in unit lies in the ceiling or runs downflow
  • 4-ton R-410A central air conditioner
  • Replacing a 4-ton coil
  • Projects where the unit’s orientation is not settled yet
1,200 to 2,000 CFMThe airflow range of the performance table Arcoaire publishes for this model.
MultipoiseVertical upflow, vertical downflow or horizontal: one part for all three orientations.
ConstructionAll-aluminum microchannel, corrosion-resistant PBT condensate drain pan, fully insulated 24-gauge cabinet.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerArcoaire
TypeCased V evaporator coil (Power-V), multipoise
ConfigurationVertical upflow, vertical downflow or horizontal
Nominal size4 tons (48,000 BTU/h)
RefrigerantR-410A
Metering deviceThermostatic expansion valve (TXV), factory installed
Airflow (performance table)1,200 to 2,000 CFM
Liquid connection3/8 in
Suction connection7/8 in
Cabinet width (dimension B)21 in
Furnace for flush fit21 in (533 mm) wide
Other drawing dimensionsA 21-15/16 · C 19-1/4 · D 20-1/16 · E 18-5/16 · F 10-1/2 · J 17-1/8 in
Operating weight38.2 lb (17.3 kg)
Shipping weight45.4 lb (20.6 kg)
CoilAll aluminum (microchannel)
Condensate drain panPBT, corrosion resistant
Cabinet24-gauge pre-painted gray steel, fully insulated (R-2.1, foil faced)
ApplicationAir conditioning only
CertificationsUL and c-UL listed; AHRI rated
Manufacturer warrantyParts: 10 years with timely registration, 5 years if not registered within 90 days of installation
StandardsUL, c-UL
Model numberEVM4X48M21A
03 · Before installing

What to know before installing

  • Air conditioning only: Arcoaire states this model does not pair with a heat pump.
  • Sold alone: not eligible for the LogisVert grant; no efficiency rating of its own.
  • The blower and ductwork must be able to move 1,200 to 2,000 CFM.
  • 3/8 in (liquid) and 7/8 in (suction) connections, for an R-410A air conditioner.
  • Available while supplies last.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
ARCOAIRE
See all
06 · Questions

Frequently asked questions

How does it differ from the EVD4X48M21A coil?

Both are 4-ton Arcoaire coils for a 21 in unit. The EVD4X installs vertically only; the EVM4X48M21A is multipoise and also accepts a horizontal installation.

Can my system deliver the airflow needed?

Arcoaire publishes this coil’s performance between 1,200 and 2,000 CFM. We check the blower and the duct sizes during the estimate; if a correction is needed, it is included in the quote.

Which refrigerant lines are needed?

A 3/8 in liquid line and a 7/8 in suction line, connected to a 4-ton R-410A air conditioner.

Can it be paired with a heat pump?

No. The manufacturer limits this model to air conditioning. Heating with the outdoor unit requires a complete central heat pump.

How much does it weigh?

38.2 lb (17.3 kg) operating and 45.4 lb (20.6 kg) shipping, according to Arcoaire.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 4-ton coil installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.