CANAIR MCPM3036BNOD Evaporator A-Coil | 3 Tons

In stock

The Canair MCPM3036BNOD 3-ton R-410A cased coil sits on your furnace and, matched with a matching Canair outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberMCPM3036BNOD

3 tons36,000 BTU/h nominal
17-1/2 inwidth
R-410Arefrigerant
R-410AAdd-on heat pumpCasedR-410A
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberMCPM3036BNOD
ManufacturerCanair
Size3 tons
Width17-1/2 in
RefrigerantR-410A
MeteringPiston (orifice fixe) installé en usine; trousse TXV en option

Humidity, comfort and condensate: the 3-ton MCPM3036BNOD (17-1/2 in)

A central air conditioner does more than lower the temperature. In a South Shore or Laval home in the middle of a sticky summer, what really changes your life is the air becoming dry. The Canair MCPM3036BNOD evaporator coil is the part that does this work: a 3-ton (36,000 BTU/h) A-coil with a 17-1/2 in casing that runs on R-410A.

The coil, a cold surface that dries the air

When the warm, humid air of the house brushes against the cold fins, the water vapour condenses, like on a glass of lemonade. This liquid runs into the pan, then into the drain. The air returning to the rooms is therefore cooler and drier. The more steadily the coil runs, the more moisture it removes: that is why a well-chosen size is better than one that is too generous.

Where does it go, and how?

In the plenum of a furnace or blower cabinet. The insulated casing holds the coil, the pan and the connections. Its dimensions (W × H × D) are 17-1/2 × 20 × 21 in, and the manufacturer lists four positions: upflow, horizontal right, downflow, horizontal left. A homeowner whose furnace hangs in an attic space can therefore orient it as needed.

The water's path, from start to finish

  • Condensate forms on the coil and drops into the built-in pan.
  • The 3/4 in NPT female primary drain carries it to a floor drain or a condensate pump.
  • A secondary drain of the same diameter acts as a safeguard in case of a blockage.
  • We set even slopes and add a trap when the floor drain calls for it.

In a finished basement, we also show you how to check the drainage with a small glass of water in the spring.

Connections and metering device

The liquid line connection is 3/8 in. The refrigerant flow is set by a factory-installed piston (fixed orifice); a TXV kit is available as an option. The piston suits everyday use well; the TXV valve adjusts further when the load varies a lot over the course of the day. We decide with you based on the outdoor unit and the house.

3 tons: are they the right proportions for your house?

This size suits many bungalows and cottages in Greater Montreal, but only a load calculation confirms it. We measure the windows, assess the insulation of the walls and roof, note the afternoon sun exposure and count the rooms served by the ducts. If the result calls for 2.5 tons or 4 tons, we tell you.

Comparison with the rest of the series

At the same 3-ton capacity, the series offers three widths:

  • MCPM3036ANOD: 14-1/2 in, for a narrow furnace;
  • MCPM3036BNOD (this one): 17-1/2 in;
  • MCPM3036CNOD: 21 in, for a wide furnace.

The 17-1/2 in width is also found on the MCPM2430BNOF (2.5 tons) and the MCPM4248BNOF (4 tons). All models in the series are cased A-coils, use R-410A and have a factory piston.

A system, not a loose part

The coil has no efficiency rating of its own. SEER2, EER2 and HSPF2 belong to the complete match, identified by an AHRI number. Canair does not publish any AHRI or ENERGY STAR match for the MCPM NOD/NOF coils; we validate it with the distributor based on the outdoor unit, before ordering anything.

The brand is distributed in Quebec by Descair. The 4CDH20 central heat pump, on R-454B, is matched with cased CEB coils; the MCPM and MAC models on R-410A are intended for previous-generation systems.

The job: order of operations

  1. Visit: furnace measurements, blower, electrical panel.
  2. Coil installed in the plenum, with an insulated transition if needed, and duct connections sealed.
  3. Outdoor unit on a pad or bracket; brazed piping, nitrogen leak test, vacuum.
  4. Condensate drain and thermostat.
  5. Commissioning, airflow adjustment, explanations.

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years; the work is done under RBQ licence 5645-9605-01. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore.

After installation: three habits to keep the air dry

A clean coil dries better. Replace the furnace filter at regular intervals, especially during the warm season, because a clogged filter reduces airflow and makes the fins frost over. Also keep the return grilles clear: a piece of furniture in front of one chokes the system. Finally, watch the drain on a humid day: a thin trickle of water running out is a good sign.

These habits take less than ten minutes a month, and they extend the life of the coil as well as the blower. We go over them when we hand over the system, with a short written reminder for each member of the family.

What this model does not do

It does not replace a dehumidifier in a basement where water seeps in, and it does not fix poorly insulated ducts in a scorching attic. If we see such defects at the visit, we point them out: a good coil in a deficient air network gives mediocre comfort. Sometimes a few simple duct fixes do more for your summer than a change of capacity.

Three important checks

  • R-410A is matched with an outdoor unit that uses the same refrigerant.
  • The furnace must have the right width, or a transition will be built.
  • The blower must be able to deliver the system's airflow; otherwise, comfort suffers.

The manufacturer's warranty is not published for this model. We confirm it in writing with the quote.

With a heat pump, winter too

If the outdoor unit is a heat pump, the cycle reverses in the cold season and the same coil warms the air passing through your ducts. The furnace keeps its blower and serves as backup heat below the outdoor temperature threshold we set with you. With a central air conditioner, the coil stays dedicated to cooling.

Questions customers often ask

Can the coil be used on its own? No: it is part of a system with an outdoor unit using the same refrigerant, installed along with it.

Do I have to change my ducts? Generally not. We check their condition and airtightness, then seal the connections at the plenum.

When can I have the system installed? We set a date after the visit and the confirmation of the match, depending on equipment availability.

Hydro-Québec incentives

Eligibility, notably for the LogisVert program, depends on the matched system and not on the coil alone. We check the official list based on the installation date and tell you what applies before you sign.

Next step

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Canair system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The MCPM3036BNOD sits in the plenum of a furnace or air handler. Connected to a matching Canair outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Canair outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-410A refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerCanair
ModelMCPM3036BNOD
TypeCased evaporator coil
LineMCPM
Nominal size3 tons (36,000 BTU/h)
RefrigerantR-410A
Metering devicePiston (orifice fixe) installé en usine; trousse TXV en option
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D17-1/2 × 20 × 21 in
Model numberMCPM3036BNOD
03 · Before installing

What to know before installing

  • R-410A refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
CANAIR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-410A and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-ton Canair coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.