CANAIR MCPM4248DNOF Evaporator A-Coil | 4 Tons
The Canair MCPM4248DNOF 4-ton R-410A cased coil sits on your furnace and, matched with a matching Canair outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberMCPM4248DNOF
514 316-2973 · sales@airgreen.ca
Quick facts
MCPM4248DNOF: the 24-1/2 in casing for large furnaces, in 4 tons
The letter D in the Canair model number signals the widest footprint in the 4-ton family: 24-1/2 in. The MCPM4248DNOF evaporator coil is meant for large furnaces and blower cabinets designed for high volumes of air. It is a cased A-coil, rated at a nominal 48,000 BTU/h, running on R-410A.
A big house, a big housing
In Laval, on the North Shore or in Longueuil, you find large two-storey houses with finished basements and sometimes an addition built twenty years ago. Their furnace is often wide, because it has to push a lot of air. A 24-1/2 in casing avoids choking that air at the coil's inlet. The dimensions (W × H × D) are 24-1/2 × 30 × 21 in.
If the furnace is narrower than 24-1/2 in
The coil can be connected to a narrower furnace with a transition built and insulated on site. But a large transition is not free: it costs labour and static pressure. In that case, the MCPM4248CNOF (21 in) or the MCPM4248BNOF (17-1/2 in) may be a better fit. It is the actual footprint of your furnace that decides, not capacity alone.
Side-by-side look at the three 4-ton models
- MCPM4248BNOF: 17-1/2 in, for a narrow furnace;
- MCPM4248CNOF: 21 in, intermediate width;
- MCPM4248DNOF (this one): 24-1/2 in, for a wide furnace.
For the same 24-1/2 in width, the MCPM4860DNOF offers 5 tons. The other published data are identical: A shape, casing, R-410A, factory piston, optional TXV kit.
Why large air volumes change things
A 4-ton coil moves a lot of air. The wider the passage, the lower the speed through the fins, which reduces noise and helps the coil work under good conditions. But the air still needs a clear path: ducts that are large enough, a return that is open enough and a clean filter. We check these three points at the same time as the blower.
Technical details at a glance
- type: cased evaporator coil, A shape;
- nominal capacity: 4 tons (48,000 BTU/h);
- liquid connection: 3/8 in;
- condensate drain: 3/4 in NPT female, primary and secondary;
- positions: upflow, horizontal right, downflow, horizontal left;
- metering: factory piston (fixed orifice), optional TXV kit;
- warranty: not published for this model, confirmed in writing with the quote.
Which outdoor unit goes with it?
A Canair unit of the same capacity and the same refrigerant. SEER2, EER2 and HSPF2 ratings belong to the certified system, linked by an AHRI number. For the MCPM NOD/NOF coils, Canair does not publish any AHRI or ENERGY STAR match: we therefore validate the match with the distributor, Descair, before ordering.
The Canair 4CDH20 central heat pump on R-454B is paired with cased CEB coils; the MCPM4248DNOF, for its part, belongs to the previous-generation R-410A family.
How we work on a big job
A large house calls for method. We walk through each floor first to note the registers and returns. On installation day, we protect the floor, cut the power and prepare the plenum. The coil installation is followed by the outdoor unit setup, the brazed piping, the nitrogen test and the vacuum. We finish with the drain, the thermostat, commissioning and a room-by-room airflow adjustment.
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore.
Heating with the same installation
Matched with a heat pump, the coil also heats the house in winter, through the existing ducts. The furnace takes over only below the outdoor temperature threshold set with you. In a large house, this sharing of roles can lighten the furnace's load for a good part of the cold season.
To check before ordering
- R-410A requires an outdoor unit with the same refrigerant.
- The furnace must have the 24-1/2 in width, or the transition will be built.
- The blower must reach the airflow of the 4-ton system.
- The electrical service must accommodate the outdoor unit's circuit.
Noise and acoustic comfort
A large casing and a large, well-directed volume of air often give a quieter system: the air moves slowly, with no whistling at the registers. Conversely, an undersized duct behind a 4-ton coil produces an audible, uncomfortable rush of air. We listen to the system at commissioning, measure the airflow room by room and adjust the registers as needed.
Choosing the outdoor unit's location
The outdoor unit goes on a pad or bracket, at a good distance from bedroom windows, away from places where snow piles up and without blocking passage. In Montreal neighbourhoods where yards are narrow, we look for the spot that respects your neighbours and leaves access for maintenance. On the North Shore and South Shore, where lots are larger, we favour proximity to the plenum to shorten the piping.
Common questions about this model
Can this coil heat? Yes, with a heat pump; with a central air conditioner, it only cools.
Can I keep my current air conditioner? Generally not: you need an outdoor unit with the same refrigerant, installed along with the coil.
Is the furnace still useful? Yes, it keeps its blower and serves as backup during the coldest weather.
What you keep from your current installation
The furnace, its blower, its filters and your ducts stay in place. Only the coil, the outdoor unit and the refrigerant piping are new. In a large house, this avoids opening finished walls or ceilings, and the job is limited to the basement, the plenum and the yard. We protect surfaces and clean up behind us.
If your furnace is nearing the end of its life, let us talk about it at the visit: it may be sensible to plan its replacement at the same time, so that the two units are designed together.
Government assistance
Hydro-Québec incentives, including LogisVert, are assessed on the complete system and not on the coil. We confirm eligibility based on the installation date, using the official list, and tell you what applies.
A clear quote
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Canair system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The MCPM4248DNOF sits in the plenum of a furnace or air handler. Connected to a matching Canair outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Canair outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-410A refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 24-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
CANAIRSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-410A and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton Canair coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.