CANAIR MCPM3036CNOD Evaporator A-Coil | 3 Tons

In stock

The Canair MCPM3036CNOD 3-ton R-410A cased coil sits on your furnace and, matched with a matching Canair outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberMCPM3036CNOD

3 tons36,000 BTU/h nominal
21 inwidth
R-410Arefrigerant
R-410AAdd-on heat pumpCasedR-410A
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberMCPM3036CNOD
ManufacturerCanair
Size3 tons
Width21 in
RefrigerantR-410A
MeteringPiston (orifice fixe) installé en usine; trousse TXV en option

MCPM3036CNOD: the 21 in casing for a wide, 3-ton furnace

Some furnaces are wide: high-efficiency models, blower cabinets designed for large volumes of air, installations that have already carried a central air conditioner. For those, a 14-1/2 in coil would mean building a major transition. The Canair MCPM3036CNOD, at 21 in wide, fits the housing better. It is a cased A-shaped evaporator coil, rated at 3 tons (36,000 BTU/h), running on R-410A.

A typical installation day, hour by hour

Because a job is easier when it is explained in advance, here is how an installation of this coil goes at a customer's home in Longueuil, Laval or Montreal.

Early morning. We protect the floor, cut the power to the furnace and measure the plenum one last time. We check the blower and the electrical panel.

Midday. The coil slides into the plenum. Its dimensions (W × H × D) are 21 × 20 × 21 in. If the furnace housing is a little narrower, we build an insulated transition; the air duct connections are sealed to prevent leaks.

Early afternoon. Outside, we set the unit on a pad or bracket, braze the piping, then leak-test with nitrogen and pull a vacuum. The coil's liquid connection is 3/8 in.

End of day. Condensate drain, thermostat, commissioning, airflow adjustment and a guided walkthrough with you.

The possible positions

The manufacturer states that the casing is multipoise: upflow, horizontal right, downflow or horizontal left. It has two 3/4 in NPT female drain outlets, one primary and one secondary. In an attic space or crawl space, we choose the orientation that allows the most natural slope toward the floor drain.

The widest of the three 3-ton sizes

In the series, the three 3-ton models differ only by width: the MCPM3036ANOD is 14-1/2 in, the MCPM3036BNOD is 17-1/2 in, and this one is 21 in. Beyond the 3-ton capacity, the 4-ton models come in 17-1/2 in, 21 in and 24-1/2 in; the 5-ton models, in 21 in and 24-1/2 in.

The MCPM3036CNOD therefore shares its 21 in width with the MCPM4248CNOF and the MCPM4860CNOF, but not their capacity. If your furnace is wide and the house is medium to large, this is the right match. If the house needs more than 3 tons, width is not enough: the load calculation decides.

How all of this cools

The refrigerant flows through the coil's tubes and turns to vapour as it picks up heat from the air. The furnace blower moves the air back and forth between the rooms and the plenum. The factory-installed piston (fixed orifice) sets the refrigerant feed; a TXV kit is available as an option, if you prefer a valve that follows the load.

Compatibility and certified matching

This coil has no efficiency rating of its own. SEER2, EER2 and HSPF2 ratings are calculated on the complete system. No AHRI or ENERGY STAR match is published for the MCPM NOD/NOF coils: we validate it with the distributor based on the outdoor unit chosen, and we give you the exact AHRI number before the order.

Canair is a brand distributed in Quebec by Descair. Its 4CDH20 heat pump on R-454B is matched with cased CEB coils; the MCPM and MAC models on R-410A serve older systems.

Wide furnace, wide coil: why it is more than a matter of looks

When the casing and the furnace are the same width, the air flows straight, with no abrupt narrowing. The connections are shorter, there are fewer joints, and the risk of air leakage drops. That translates into a quieter, more even system. Conversely, a transition that is too pronounced creates eddies that make noise and reduce useful airflow.

That is why we recommend the width closest to the furnace, rather than choosing at random among the three 3-ton models.

A house that already has a central air conditioner

Many homeowners in Montreal, Laval and the North Shore already have an ageing central air conditioner. In that case, replacement is often the most direct route: same furnace, same ducts, new coil and new R-410A outdoor unit. We check the condition of the piping, the thermostat's compatibility and the cleanliness of the plenum before settling on a work plan.

If the old system performed poorly, we first look for the reason: lack of airflow, blocked drain, unsuitable refrigerant charge. Replacing the unit without understanding the cause risks repeating it.

What this coil changes in winter

Matched with a heat pump, it also heats the rooms through the existing ducts. The furnace only comes on below the outdoor temperature threshold set with you. Matched with a central air conditioner, it only provides summer cooling.

Checkpoints before ordering

  • R-410A refrigerant: outdoor unit with the same refrigerant, installed along with the coil.
  • 21 in width: matches the furnace housing or a transition is planned.
  • Blower suited to the system's airflow.
  • Manufacturer's warranty not published for this model: confirmed in writing with the quote.

About AirGreen

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore.

Three questions to ask any installer

What is the AHRI number of the proposed match? How was the load calculation done, and can you give it to me? What happens if the blower cannot deliver the planned airflow? At AirGreen, we answer these three questions in writing, before you sign, whether the project involves this MCPM3036CNOD or another model in the series.

A good quote does not hide its assumptions: it states the capacity, the casing width, the refrigerant, the metering device and the proposed match, then itemizes labour, materials and any electrical or ductwork required.

Incentives

Hydro-Québec programs, including LogisVert, look at the complete system and not at the coil on its own. We confirm eligibility based on the installation date, against the official list, before offering you a final price.

Get your price

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Canair system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The MCPM3036CNOD sits in the plenum of a furnace or air handler. Connected to a matching Canair outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Canair outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-410A refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerCanair
ModelMCPM3036CNOD
TypeCased evaporator coil
LineMCPM
Nominal size3 tons (36,000 BTU/h)
RefrigerantR-410A
Metering devicePiston (orifice fixe) installé en usine; trousse TXV en option
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D21 × 20 × 21 in
Model numberMCPM3036CNOD
03 · Before installing

What to know before installing

  • R-410A refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
CANAIR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-410A and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-ton Canair coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.