COMFORTMAKER EAM5X24M14A Evaporator A-Coil | 2 Tons
The Comfortmaker EAM5X24M14A 2-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker B5H3V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEAM5X24M14A
514 316-2973 · sales@airgreen.ca
Quick facts
The EAM5X24M14A: a 2-ton Comfortmaker evaporator coil built for narrow furnaces
In many Montreal homes, the furnace is not housed in a large, open basement: it sits in an alcove, a utility closet or a corner wedged between a concrete wall and the hot-water boiler. The Comfortmaker EAM5X24M14A evaporator coil was designed for exactly these tight spots. Its 14-3/16 in wide cabinet is one of the slimmest in the series, in a 2-ton size (24,000 BTU/h) with R-454B refrigerant.
We install it in Montreal, Laval, Longueuil, the North Shore and the South Shore, always after measuring the furnace on site.
Why the cabinet width decides everything
The cabinet sits on top of the furnace, in the air outlet plenum. If the coil is wider than the unit, air slips out through the sides and the seal suffers; if it is narrower, a transition piece has to be built. At 14-3/16 in, this model fits small-footprint furnaces without any improvised fixes.
Its height is 25-13/16 in, and it weighs 50.1 lb: a reasonable weight to handle on a basement staircase or through a ceiling hatch.
A word on the A shape and the three positions
The two faces of the coil meet at the top, like a roof with two slopes. The warm or cool air from the blower passes through these faces before moving on into the ducts. The manufacturer allows upflow, downflow or horizontal installation, which helps when the furnace lies on its side in a crawl space or hangs in an attic.
Two FRTP drain pans, one vertical and one horizontal, are supplied, both sloped so the water runs toward the drain. The suction connection is 5/8 in and the expansion device is a TXV type.
Cooling with 2 tons: what to expect
A system of this size suits a well-insulated bungalow, a plex ground-floor unit or a single storey of a townhouse. More than the number of square feet, it is the windows, the orientation, the roof insulation and the air leaks that decide. That is why we run a load calculation before proposing anything.
A well-matched capacity avoids the on-off cycling that leaves the air cool but damp. The result is felt most during long spells of muggy heat.
The certified systems for this model
Like any coil, this one has no rating of its own; the following figures belong to the published systems:
- B5H3V24*K*AAA, AHRI number 218405915: 21,600 BTU/h cooling, 26,600 BTU/h heating at 47 °F, SEER2 19.0, HSPF2 9.5.
- C5H0V24*K*AAA, AHRI number 215666934: 22,800 BTU/h cooling, 24,000 BTU/h heating at 47 °F, SEER2 17.0, HSPF2 9.0.
- C5H8T24*K*AAA, AHRI number 216364538: 22,200 BTU/h cooling, 25,000 BTU/h heating at 47 °F, SEER2 15.5, HSPF2 8.0.
The first system shows the highest ratings of the three; the other two are justified by the choice of outdoor unit line, depending on noise, budget and the space available in the yard.
Choosing between the EAM5X24M14A and its neighbours
- Versus the EAM5X24M17A: same 2-ton capacity, same B5H3V24*K*AAA outdoor unit, but the cabinet of the latter is 17-1/2 in wide. Your furnace settles the question.
- Versus the EAM5X25M17A: also 2 tons, but at 17-1/2 in and paired with the Q5H9V24*K*AAA.
- Versus the EAM5X19M17A: 1.5 tons, smaller, for low-load spaces.
- Versus the EAM5X30M14A: same width of 14-3/16 in, but 2.5 tons for a house that needs more.
All of them share R-454B, the TXV expansion device and Comfortmaker manufacturing.
What the add-on heat pump does
Paired with a heat pump, the coil lets you heat in mild temperatures with the outdoor unit, while the furnace stays in reserve for the deep cold. The changeover threshold is programmed with you at start-up. If your furnace is electric, the difference in consumption can be significant, because the heat pump moves heat instead of simply producing it.
The installation, step by step
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. For this coil:
- measuring the furnace dimensions, checking the blower and the electrical panel;
- setting the coil in the plenum, with an insulated transition built on site if necessary, then sealing the joints;
- installing the outdoor unit, brazing the piping, nitrogen pressure test and vacuum pull;
- connecting the condensate drain and the thermostat;
- start-up, airflow adjustment and a walk-through of how it all works with you.
When the work space is limited
A furnace housed in a closet raises a practical question: how do you reach the plenum, the drain and the connections? During the visit, we look at the clearance above the unit, the path for the piping and the place where condensation can drain without backing up. It is better to spot an obstacle before delivery than on installation day.
A party wall, a closet door fitted to the millimetre or a plumbing pipe that crosses the plenum are easy to handle when they are known in advance. We take photos, note the dimensions, then confirm the plan in writing.
What you will notice after installation
From the first hot day, the difference is felt mostly in the humidity: the air is drier, the house is more even from room to room, and you stop hauling a window air conditioner from one floor to another. In winter, if a heat pump is connected, the furnace runs far less often.
Finally, think about basic maintenance: a clean filter at regular intervals and a clear condensate drain protect the coil and extend its life. We explain where these points are during start-up.
Refrigerant safety and warranty
The coil ships with a leak sensor and its harness already installed at the factory, while the dissipation board, the enclosure and the power harness are in the parts box. The manufacturer grants a 10-year limited warranty on parts if the unit is registered within 90 days of installation; without registration, the term drops to 5 years.
To confirm before ordering
- The outdoor unit must be R-454B and installed at the same time as the coil.
- The ratings apply to the certified system, not to the coil alone.
- The blower must be able to move the required volume of air.
- The furnace width must be confirmed: if the gap is significant, the transition is built on site.
LogisVert subsidy
This Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your personal situation. We check the official list when we prepare your quote and put the application together with you.
Plan a visit
Ask for a free in-home estimate: we measure your furnace, examine the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread out the cost of the work.
The heat pump coil for your furnace
The EAM5X24M14A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker B5H3V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker B5H3V24*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 14-3/16 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.