COMFORTMAKER EAM5X30M17A Evaporator A-Coil | 2.5 Tons
The Comfortmaker EAM5X30M17A 2.5-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker Q5H9V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEAM5X30M17A
514 316-2973 · sales@airgreen.ca
Quick facts
Installing the EAM5X30M17A: how a typical day goes with a 2.5-ton Comfortmaker coil
When you invest in a central system, the main question is what the job site will look like. This page walks through, in order, what happens at your home when we install the Comfortmaker EAM5X30M17A evaporator coil, a cased A-coil model, nominal size 2.5 tons (30,000 BTU/h), with R-454B refrigerant, 17-1/2 in wide. It serves homes in Montreal, Laval, Longueuil, the North Shore and the South Shore.
Before the day: the visit and the quote
It all starts with a visit. We measure the furnace, we look at the blower, we examine the electrical panel and we look for the most logical route for the piping. We confirm that the 17-1/2 in width matches your unit, or we plan for an insulated transition.
You then receive a written quote that names the coil, the outdoor unit and the AHRI number of the system. This detail lets you check the ratings yourself.
The day before: what you can prepare
A little preparation makes the day go more smoothly. Clear a path to the furnace and to the wall where the piping will exit, move fragile objects nearby and tell us where you would like the outdoor unit. If a pet roams freely, plan another spot for it for the day: the doors will be open during the comings and goings.
We also ask you to locate the furnace breaker and the outdoor unit breaker, if a circuit already exists. This saves us from searching the panel and speeds up the electrical check.
The morning: the furnace and the plenum
The crew arrives, protects the floor and cuts power to the furnace. The cabinet, which weighs 61 lb at 17-1/2 × 25-13/16 in, is lifted onto the air outlet and fitted to the plenum. Every joint is sealed to prevent air leaks. If your furnace has a different width, the insulated transition is built at that point, on site.
The A-coil comes with a TXV expansion device; two FRTP pans, one vertical and one horizontal, are sloped to direct condensation toward the drain. We choose the one that matches your furnace position: upflow, downflow or horizontal.
Midday: the piping and the outdoor unit
The outdoor unit is installed on a pad or a stand. The refrigerant tubes, whose suction connection measures 3/4 in at the coil end, are brazed and run through a single hole in the wall. Next comes the nitrogen leak test, then the vacuum pull that removes air and moisture from the piping.
The coil also includes an A2L leak sensor with a harness installed at the factory; the dissipation board, the enclosure and the power harness come in the parts box and are mounted at this stage.
End of the day: start-up
We connect the condensate drain and the thermostat, we open the refrigerant, we start the system and we adjust the airflow. Before leaving, we explain how the thermostat works, where to change the filter and what threshold we programmed so that the furnace takes over in the deep cold.
The certified systems for this coil
Two outdoor units are published with it:
- Q5H9V24*K*AAA, AHRI 217953812: cooling 22,200 BTU/h, heating 23,800 BTU/h at 47 °F, SEER2 15.2, HSPF2 9.0.
- N5H9V24*K*AAA, AHRI 217953805: same capacities and same ratings.
Comfortmaker also lists ENERGY STAR pairings under the "EA*5X" family and a heating capacity at -8.3 °C between 10,700 and 40,000 BTU/h depending on the pairing. Remember that a coil has no rating of its own: it is the systems that carry one.
The EAM5X30M17A against its neighbours
- Against the EAM5X30M14A: same capacity and same units, but that one is narrower, at 14-3/16 in.
- Against the 2-ton models: EAM5X24M17A, EAM5X25M17A and EAM5X24M14A offer less nominal capacity.
- Against the 3-ton models: EAM5X36M17A, EAM5X37M17A and EAM5X36M21A offer more, for more demanding homes.
All of these models share R-454B refrigerant, the TXV expansion device and Comfortmaker manufacturing.
What stays in place
This setup keeps your furnace's blower, filters and control panel, as well as your ducts. You do not open any walls to run new ones. With a heat pump, in winter, the furnace serves as backup at the lowest temperatures; in summer, the coil cools and dries the air.
Why the 17-1/2 in width comes up so often
In the EAM5X series, most models are offered at 17-1/2 in. It fits many furnaces, and the custom transition is only needed when the gap is real. When your unit is narrower, we build it; when it is wider, we look at whether a wider model in the series is preferable.
The choice between two widths changes neither the capacity nor the rating of the system: it is only a question of fit between the cabinet and the furnace.
What if my furnace is electric?
An electric furnace is a good candidate for this conversion. The heat pump provides heat for most of the season, and the furnace's electric elements serve only as backup. We set the changeover threshold between one source and the other with you, according to your habits and the electricity rate that applies at your home.
After the installation
We stay available. If a room seems less comfortable, if the drain makes an unusual noise or if the thermostat seems hard to set, call us: an airflow adjustment or a change to the changeover threshold often settles the situation quickly. Also keep your model number handy: it speeds up any conversation with our team.
The questions that come up most
Does this coil heat too? Yes, with a heat pump; with a central air conditioner, it is limited to cooling. Can I keep my current outdoor unit? Generally not, since R-454B requires the unit specified by the manufacturer. Who handles the subsidy? We check eligibility on the official list and put the application together with you.
Our team and our licences
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01.
Before confirming the purchase
- R-454B requires an outdoor unit using the same refrigerant, installed at the same time.
- The ratings apply to the certified system, not to the coil alone.
- The blower must deliver the required airflow, which we check during the visit.
The manufacturer grants a ten-year limited warranty on parts with registration made within 90 days of installation, and five years without registration.
LogisVert subsidy
The paired Comfortmaker system is listed on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation; we check the official list when we prepare your quote and put the application together with you.
Book your visit
The estimate is free and done at your home: we measure the furnace, we check the electrical service and we provide a written quote for the complete Comfortmaker system. Financing is available to spread out the cost.
The heat pump coil for your furnace
The EAM5X30M17A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker Q5H9V24*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2.5-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.