COMFORTMAKER EAM5X30M14A Evaporator A-Coil | 2.5 Tons

In stock

The Comfortmaker EAM5X30M14A 2.5-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker Q5H9V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberEAM5X30M14A

2.5 tons30,000 BTU/h nominal
14-3/16 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 217953796
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEAM5X30M14A
ManufacturerComfortmaker
Size2.5 tons
Width14-3/16 in
RefrigerantR-454B
MeteringTXV
Outdoor unitQ5H9V24*K*AAA

EAM5X30M14A: 2.5 tons in a slim cabinet, for the average home with a compact furnace

The 2.5-ton size sits in the middle of the EAM5X range. With the Comfortmaker EAM5X30M14A evaporator coil, it also fits in a cabinet 14-3/16 in wide: this is the combination you look for when the house needs a little more than a small system, but the furnace stays modest in size.

This nominal 30,000 BTU/h model, with R-454B refrigerant, is installed by AirGreen in Montreal, Laval, Longueuil, the North Shore and the South Shore.

Two numbers not to confuse

The first is the nominal size: 2.5 tons, or 30,000 BTU/h. This is the label of the family, the one used to classify coils. The second is the published capacity for a system: for this coil paired with a Q5H9V24*K*AAA unit, it is 22,200 BTU/h cooling. The two do not contradict each other, but they are not interchangeable either.

When you compare quotes, always ask which capacity is being quoted. A round number on a brochure does not replace the certificate for the system.

The certified systems

  • Q5H9V24*K*AAA, AHRI 217953796: 22,200 BTU/h cooling, 23,800 BTU/h heating at 47 °F, SEER2 15.2, HSPF2 9.0.
  • N5H9V24*K*AAA, AHRI 217953789: same capacities and same ratings.

Only two units are published for this coil, against three for some 2-ton models. The choice is therefore simple, and it comes down mostly to where the unit sits in the yard, availability and budget.

The piping: a 3/4 in suction connection

This coil has a 3/4 in suction connection. This directly affects the refrigerant piping between the furnace and the outdoor unit: the tubes must match. Our technicians check the route, the length and the diameter before drilling through the foundation wall.

The connections are brazed, then the piping goes through a nitrogen leak test and a vacuum pull before the refrigerant is released.

Dimensions, weight and configuration

  • Width 14-3/16 in, height 25-13/16 in; net weight 54.5 lb.
  • A-coil in an insulated cabinet, with TXV expansion device.
  • Can be installed upflow, downflow or horizontal.
  • Two FRTP condensate pans, vertical and horizontal, sloped.
  • Factory-installed A2L leak sensor, with a harness; the dissipation board, the enclosure and the power harness are in the parts box.

How to choose between this model and its neighbours

The choice comes down to three criteria: capacity, width and outdoor unit.

  • EAM5X30M17A: same 2.5-ton capacity, same Q5H9V24*K*AAA and N5H9V24*K*AAA units, but a wider cabinet, at 17-1/2 in.
  • EAM5X24M14A: same width of 14-3/16 in, but 2 tons, paired with the B5H3V24*K*AAA.
  • 3-ton models: EAM5X36M17A, EAM5X37M17A and EAM5X36M21A, for heavier loads.

If the load calculation lands on the line between 2 and 2.5 tons, we prefer to study the windows, the insulation and the air distribution rather than decide by eye.

The furnace keeps its role

In an "add-on" setup, the furnace keeps its blower, its filters and its role as backup heat. In summer, the coil cools the air passing through it. In winter, with a heat pump, it releases the heat captured outdoors. In very cold weather, the furnace takes over at a threshold that we adjust with you.

This combination avoids redoing the ducts and leaves the house in its original state.

A medium-sized house, in practice

Think of the two-storey cottage whose furnace serves the kitchen and the bedrooms alike, the extended bungalow or the two-generation home whose living room is sunny all afternoon. What these homes have in common is a cooling load higher than a compact unit, without requiring the largest size in the series.

In these homes, two things matter more than floor area: windows facing south or west and the state of the roof insulation. A poorly insulated attic can by itself push up the air conditioning bill; we always look at it during the visit, and we point it out if a simple improvement can reduce the load.

The shoulder season, between furnace and heat pump

Another advantage of the add-on heat pump: in the shoulder season, in spring and fall, the unit can provide mild heating on its own, without turning on the furnace. The coldest months remain the domain of the backup heat, which then takes over. You move from one mode to the other without thinking about it, since the thermostat controls the whole system.

If you go away on a trip, you can set an economy temperature, as with any central system. The return to normal temperature happens gradually.

Basic maintenance

A clean coil works better. Replace the filter at regular intervals, keep the condensate drain clear, and keep the area around the outdoor unit free of leaves and snow. We show you where these points are at start-up; do not hesitate to ask us questions after the installation.

The installation at your home

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, holder of RBQ licence 5645-9605-01. For this coil, here is our sequence:

  • measuring the furnace, examining the blower and the electrical panel;
  • installing the coil in the plenum, with an insulated transition built as needed, and sealing the air connections;
  • installing the outdoor unit on a stand, brazing, nitrogen test and vacuum pull;
  • connecting the condensate drain and the thermostat;
  • start-up, airflow adjustment and a demonstration.

What the warranty covers

The manufacturer offers a 10-year limited warranty on parts if registration is done within 90 days of installation; without registration, the period is 5 years. We handle this formality with you.

Before you buy, check this

  • R-454B calls for an outdoor unit using the same refrigerant, installed at the same time.
  • The advertised ratings apply to the certified system, not to the coil alone.
  • The blower must move the required airflow; the furnace must be narrow enough for this cabinet, or we build the transition.

Frequently asked questions

Can this coil heat? Yes, with a heat pump. With a central air conditioner, it is limited to cooling.

Can my current air conditioner stay? Generally not: R-454B requires the unit specified by the manufacturer, and we install the complete system.

My furnace has a different width. What should I do? We measure it and, if needed, build an insulated transition on site.

LogisVert subsidy

The paired Comfortmaker system is on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check the official list when we prepare your quote and put the application together with you.

Get your project estimated

Ask for our free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is offered to spread out the cost of the work.

01 · What it is for

The heat pump coil for your furnace

The EAM5X30M14A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Comfortmaker Q5H9V24*K*AAA outdoor unit
Certified systemMatched with the Q5H9V24*K*AAA, the system carries AHRI 217953796.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelEAM5X30M14A
TypeCased evaporator coil
LineEAM5X
Nominal size2.5 tons (30,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Suction connection3/4 in
Dimensions W × H × D14-3/16 × 25-13/16 in
Net weight54.5 lb
Matched outdoor unitQ5H9V24*K*AAA, N5H9V24*K*AAA
System AHRI number217953796, 217953789
System SEER2 / HSPF215.2 / 9.0
Model numberEAM5X30M14A
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 14-3/16 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
05 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2.5-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.