GOODMAN CAHEA3630C3 Evaporator A-Coil | 2 to 5 Tons
The Goodman CAHEA3630C3 2 to 5-ton R-32 cased coil sits on your furnace and, matched with the Goodman GZV9SA241CA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAHEA3630C3
514 316-2973 · sales@airgreen.ca
Quick facts
CAHEA3630C3: a narrow 21 in. coil that covers 2 to 5 tons
In a series where most coils are 22 in., 26 in. or 30 in. wide, the Goodman CAHEA3630C3 is the exception: its cabinet is only 21 in. wide, yet it carries the "2 to 5 tons" label (60,000 BTU/h nominal size). It is a cased evaporator A-coil that runs on R-32 and bolts onto the plenum of a furnace or a blower cabinet. We install it in homes in Montreal, Laval, Longueuil, the North Shore and the South Shore.
This page explains what it is used for, which outdoor units it pairs with, what we check at your home before ordering it, and how it compares with the other Goodman coils in the same series.
Why its width matters more than its label
On a furnace, the coil has to match the width of the plenum. A compact furnace squeezed into a narrow mechanical room will not accept just any cabinet. At 21 in. wide, the CAHEA3630C3 is the narrowest in the Goodman series we offer, and that is often the reason it gets chosen: the installation goes in without a lot of improvising around the furnace.
When the width does not line up exactly, we build an insulated transition on site. The coil measures 21 × 30 × 21 in. (W × H × D); we take your furnace measurements before placing the order, never after.
One label, three published pairings
What really sets this model apart is the flexibility of its pairings. Goodman publishes three certified systems that use it:
- GZV9SA241CA outdoor unit, AHRI 216699795, cooling 24,000 BTU/h, heating 24,000 BTU/h at 47 °F, SEER2 21.0, HSPF2 10.0;
- GZV9SA361CA outdoor unit, AHRI 216699796, cooling 34,200 BTU/h, heating 34,200 BTU/h at 47 °F, SEER2 21.0, HSPF2 10.0;
- GZV9SA4810A outdoor unit, AHRI 217989204, cooling 46,000 BTU/h, heating 48,000 BTU/h at 47 °F, SEER2 18.0, HSPF2 9.0.
In other words, the same part serves as the base for a small system and for a larger one. The efficiency ratings do not belong to the coil: they belong to the coil plus outdoor unit combination, and the AHRI number is what ties them together.
What the coil actually does
Picture the air in your home rising from the furnace into the plenum. In summer, it meets the coil's tubes, which are cold because the refrigerant is evaporating inside them. Heat and some of the humidity cling to the metal; the water runs into the pan and leaves through the drain. The air comes out cooled and flows into your existing ductwork.
In winter, if the outdoor unit is a heat pump, the cycle reverses and the coil delivers heat to the air. The furnace keeps its blower, its filters and its role as backup heat for the coldest days, at a threshold we set with you.
Where it fits in the series
Here is a quick way to find your bearings among the sibling models, based on the published data sheets:
- the CHPEA2422B3 (2 tons, 22 in.) pairs with the GZV6SA1810A and suits small homes;
- the CHPEA3026B3 and CHPEA3026C3 (2.5 tons, 26 in.) go with the GZV7SA2410A;
- the CHPEA3626B3 and CHPEA3626C3 (3 tons, 26 in.) form the next step up;
- the CHPEA4830C3 and CHPEA4830D3 (4 tons, 30 in.) pair with the GZV7SA3610A;
- the CHPEA6030C3 and CHPEA6030D3 (5 tons, 30 in.) pair with the GZV7SA4210A.
All of these coils use R-32 and an electronic expansion valve (EEV), like the CAHEA3630C3. What sets it apart is the CAHEA line, the 21 in. width, the 2 to 5 ton capacity range and its multipoise design, with a horizontal kit (0270K00063) for a lay-down installation.
EEV expansion and leak detection
The expansion device is an EEV: an electronic valve controls the flow of refrigerant entering the coil. The manufacturer also provides an R-32 refrigerant sensor, designed to last the life of the coil (data sheet SS-DCoil-R32). The connections are 5/16 or 3/8 in. on the liquid side and 3/4 or 7/8 in. on the suction side; our technician chooses according to the line set of the selected outdoor unit.
Which home is it for?
This model appeals to homeowners whose furnace is narrow but whose house is large: a home with an addition, a finished basement, or an extra floor added over the years. It also suits anyone still undecided about the size of the outdoor unit, since three pairings are possible.
In very large homes, we tell you honestly whether two smaller systems would share the load better. The electrical service and the airflow of the ductwork matter as much as the tonnage label.
Warranty and manufacturer data sheets
Goodman offers a 10-year limited parts warranty, with online registration within 60 days of installation, a step that is not required in Quebec (data sheet SS-GCoil-R32). Goodman is a brand of Daikin Comfort Technologies, like Daikin and Amana, and its R-32 pairings with the GZV6SA, GZV7SA and GZV9SA heat pumps are ENERGY STAR and cold-climate certified, with the coil working alongside a Goodman MBVK modular blower.
What you gain by switching to a heat pump
A baseboard heater or an electric furnace turns a kilowatt-hour into an equal amount of heat. A heat pump instead moves heat from outdoors to indoors: in mild weather, it delivers two to three times as much heat as the electricity it uses. That efficiency drops as the cold sets in, which is why keeping the furnace as backup makes sense. In summer, the same system replaces window air conditioners and dries the air.
Your installation, from the first look to the thermostat
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For this coil, the visit and installation follow this order:
- measuring the furnace, checking the blower and looking at the electrical panel;
- mounting the cabinet in the plenum, building a transition if needed, and sealing the duct connections well;
- outdoor unit on a pad or bracket, brazed piping, nitrogen leak test and vacuum;
- condensate drain and thermostat hooked up;
- startup, airflow adjustment and a walkthrough at your home.
Before you buy, check these points
- R-32 requires an outdoor unit using the same refrigerant, installed at the same time.
- The published ratings apply only to the certified pairing set out by Goodman.
- The furnace must offer the width and airflow required: we confirm this at your home.
LogisVert subsidy
The paired Goodman system appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation: we read it from the official list when we prepare your quote, then put the application together with you.
Next step: an on-site estimate
Call us for a free estimate: we measure the furnace, look at the electrical service and give you a written quote for the complete Goodman system. Financing lets you spread the cost of the project over time.
The heat pump coil for your furnace
The CAHEA3630C3 sits in the plenum of a furnace or air handler. Connected to the Goodman GZV9SA241CA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Goodman GZV9SA241CA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2 to 5-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.