GOODMAN CHPEA4830C3 Evaporator A-Coil | 4 Tons

In stock

The Goodman CHPEA4830C3 4-ton R-32 cased coil sits on your furnace and, matched with the Goodman GZV7SA3610A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCHPEA4830C3

4 tons48,000 BTU/h nominal
30 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedAHRI 215433927
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCHPEA4830C3
ManufacturerGoodman
Size4 tons
Width30 in
RefrigerantR-32
MeteringEEV
Outdoor unitGZV7SA3610A

CHPEA4830C3: the 4-ton Goodman coil, 30 in. wide, and its three outdoor partners

With the CHPEA4830C3, we enter the territory of large homes with furnaces. It is a cased evaporator A-coil, 4 tons (48,000 BTU/h), using R-32 refrigerant, 30 in. wide and measuring 30 × 21 × 21 in. (W × H × D). What makes it interesting is that it accepts three different outdoor units, each with its own personality: one bets on capacity, the other two on heating efficiency.

Here is how to read these options, what we measure at your home and how this model compares with the CHPEA4830D3 and the other Goodman coils. We work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

A big house, a big furnace

A 30 in. width signals a good-sized furnace, the kind found in large cottages, extended split-level homes and properties whose basement serves as a games room. At this size, the blower and the duct system matter as much as the coil: a 4-ton cabinet does nothing if the air does not circulate well.

We therefore measure the furnace, test the blower and look at the diameter of the supply runs before promising a result.

The three certified pairings

Goodman publishes the following systems for this coil:

  • GZV7SA3610A outdoor unit, AHRI 215433927, cooling 35,000 BTU/h, heating 35,000 BTU/h at 47 °F, SEER2 19.0, HSPF2 8.1;
  • GZV9SA241CA outdoor unit, AHRI 216699891, cooling 23,000 BTU/h, heating 21,000 BTU/h at 47 °F, SEER2 18.2, HSPF2 9.0;
  • GZV9SA361CA outdoor unit, AHRI 216699917, cooling 33,400 BTU/h, heating 31,000 BTU/h at 47 °F, SEER2 18.2, HSPF2 9.0.

What should you take from this table? That the same coil serves systems whose capacities differ. The GZV7SA3610A gives the largest capacity of the three and the highest cooling rating. The two GZV9SA units, for their part, show a higher HSPF2 for heating, at the cost of a more modest capacity. None is "better" in itself: it all depends on what you expect, cooling or heating, and on the load of your home.

How to choose between these outdoor units

Here is the reasoning we follow with you:

  • if the priority is cooling a large area in summer, capacity matters a lot;
  • if the home is mostly heated with electricity and the winter bill worries you, HSPF2 becomes an interesting indicator;
  • if the electrical service is limited, we say so right at the visit: the outdoor unit must be able to be powered.

An honest quote gives you the exact AHRI number of the complete system, not just a brand name.

What happens inside the coil

The two faces of the A offer a large exchange surface under a compact plenum. The air rises from the furnace, passes through the fins, gives up its heat to the refrigerant evaporating in the tubes, then leaves through the ducts. The humidity is collected in a pan and carried to the drain. In heat pump systems, the cycle reverses in winter: the coil heats the air instead of cooling it, and the furnace starts only below a threshold that we set with you.

CHPEA4830C3 or CHPEA4830D3?

The two coils have the same capacity, the same 30 in. width, the same R-32, the same EEV expansion valve and the same three pairings. The difference comes down to the cabinet height: the C3's is lower, the D3's taller. When the plenum offers little vertical clearance, the C3 is therefore the natural choice; when space is generous, the D3 becomes possible.

And the other models in the series?

  • The CHPEA6030C3 and CHPEA6030D3 move up to 5 tons, same 30 in. width, with the GZV7SA4210A.
  • The CHPEA3626B3 and CHPEA3626C3 (3 tons) and the CHPEA3026B3 and CHPEA3026C3 (2.5 tons) suit 26 in. furnaces.
  • The CHPEA2422B3 (2 tons, 22 in.) is aimed at small homes.
  • The CAHEA3630C3 (2 to 5 tons) offers a cabinet only 21 in. wide.

Electrical service, ducts and blower: the trio to check

In a large home, three elements decide the success of the project far more than the name of the coil. The electrical service must accommodate the outdoor unit's circuit, without improvising. The blower must move the volume of air the system requires. As for the ducts, they must be wide enough, and tight enough, for that air to actually reach the distant rooms. We check all three during the visit, and we give you clear findings before talking about price.

Quick answers

Does this coil heat? Yes, when paired with a heat pump; with a central air conditioner, it only cools.

Can I keep my current air conditioner? Generally not: R-32 requires the outdoor unit intended by the manufacturer.

Is my furnace still useful? Yes, it keeps its blower and serves as backup in extreme cold.

CHPEA4830C3 spec sheet

  • connections: 3/8 in. on the liquid side, 7/8 or 1-1/8 in. on the suction side;
  • position: horizontal according to the manufacturer's data sheet;
  • leak detection: R-32 refrigerant sensor designed to last the life of the coil (data sheet SS-DCoil-R32);
  • 10-year limited parts warranty, with online registration within 60 days of installation (not required in Quebec; Goodman data sheet SS-GCoil-R32).

A word about the manufacturer and the heat pump advantage

Goodman belongs to Daikin Comfort Technologies, like Daikin and Amana. Its R-32 pairings with the GZV6SA, GZV7SA and GZV9SA heat pumps are ENERGY STAR and cold-climate certified, on a Goodman MBVK modular blower.

Electric heating gives as much heat as the electricity consumed. A heat pump moves heat already present outdoors: in mild weather, it delivers two to three times as much. Its efficiency drops in the cold, which explains the furnace's backup role. In summer, a single system replaces window air conditioners.

AirGreen's installation of this coil

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. Here is the essence of the job:

  • measuring the furnace, checking the blower and the electrical panel;
  • installing the cabinet in the plenum, insulated transition if needed and sealed duct joints;
  • installing the outdoor unit on a pad, brazed piping, nitrogen test, vacuum;
  • connecting the condensate drain and the thermostat;
  • startup, airflow adjustment and explanations at your home.

To validate before ordering

  • R-32 outdoor unit, installed at the same time as the coil.
  • Ratings valid for the selected certified pairing.
  • Furnace of the right width, with a blower able to deliver the required airflow.

LogisVert subsidy

The paired Goodman system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we confirm it against the official list when we prepare your quote and put the application together with you.

An on-site estimate, free of charge

Have your furnace measured for free: we also check the electrical service and give you a written quote for the complete Goodman system. Financing lets you spread out the payments for the project.

01 · What it is for

The heat pump coil for your furnace

The CHPEA4830C3 sits in the plenum of a furnace or air handler. Connected to the Goodman GZV7SA3610A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Goodman GZV7SA3610A outdoor unit
Certified systemMatched with the GZV7SA3610A, the system carries AHRI 215433927.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCHPEA4830C3
TypeCased evaporator coil
LineCHPEA
Nominal size4 tons (48,000 BTU/h)
RefrigerantR-32
Metering deviceEEV
Liquid connection3/8 in
Suction connection7/8 or 1-1/8 in
Dimensions W × H × D30 × 21 × 21 in
Matched outdoor unitGZV7SA3610A, GZV9SA241CA, GZV9SA361CA
System AHRI number215433927, 216699891, 216699917
System SEER2 / HSPF219.0 / 8.1
Model numberCHPEA4830C3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 30 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 4-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.