GOODMAN CHPEA2422B3 Evaporator A-Coil | 2 Tons
The Goodman CHPEA2422B3 2-ton R-32 cased coil sits on your furnace and, matched with the Goodman GZV6SA1810A outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCHPEA2422B3
514 316-2973 · sales@airgreen.ca
Quick facts
CHPEA2422B3: the 2-ton Goodman coil for small homes and tight spaces
A semi-detached home in Longueuil, a compact cottage in Laval, a single-storey bungalow on the North Shore: in many of these homes, the furnace is small, the basement ceiling is low and the heating bill hurts in winter. The Goodman CHPEA2422B3 evaporator coil was designed for this kind of situation. It is a cased A-coil, 2 tons (24,000 BTU/h), using R-32 refrigerant, 22 in. wide and fairly low in profile, since its cabinet is only 17-1/2 in. tall.
Here is everything you need to know before choosing it: what it does, its outdoor unit, its place among the neighbouring models, and what we check at your home in Montreal, on the South Shore and throughout Greater Montreal.
A low cabinet for tight plenums
The published dimensions are 22 × 17-1/2 × 21 in. (W × H × D). The reduced height has a practical consequence: on an upflow furnace installed in a room with a low ceiling, a lower cabinet leaves a little more space to work and to connect the ductwork. That is a real advantage, but it has to be confirmed with a tape measure: we always measure the distance between the top of the furnace and the ceiling before promising anything.
The published installation position is horizontal. This means the coil is designed for a lay-down installation, for example in a blower cabinet located in an attic or a confined space, in addition to the classic installation on a furnace.
The certified pairing: the GZV6SA1810A
Goodman pairs this coil with a single outdoor unit, the smallest heat pump in the series:
- GZV6SA1810A outdoor unit, AHRI 215439772, cooling 17,000 BTU/h, heating 16,800 BTU/h at 47 °F, SEER2 19.0, HSPF2 8.8.
Keep in mind that these ratings describe the whole system, not the coil alone. If a competing quote does not mention an AHRI number, ask for it: it is what allows you to compare equivalent systems.
What the coil does in your home
It sits in the plenum, in the path of the air pushed by your furnace blower. When the outdoor unit is running, refrigerant circulates through its tubes and cools the air passing by. Moisture condenses on the fins, drops into the pan and runs to the drain. The result: a cooler, drier room, without the noise of a window air conditioner.
With a heat pump, the cycle also runs in reverse to provide heat. The coil then releases the heat captured outdoors into the air flowing through your existing heating vents. The furnace waits in reserve for the coldest nights.
How much house can a 2-ton size serve?
A 2-ton size suits a small heated area that is well insulated and has few rooms. It does not suit a large two-storey home, and we will not sell you one just to save a few dollars up front: a system that is too small runs nonstop and leaves some rooms uncomfortable. We run a load calculation before the quote, and if your home needs more, we point you toward a larger model in the series.
For a small home, the real gain often comes down to the quality of the building envelope: windows, attic insulation, air sealing. A well-sealed house needs less capacity, and a 2-ton size can then be more than enough. We tell you this during the visit, room by room, rather than guessing from the square footage.
How it compares with its neighbours
- CHPEA3026B3 and CHPEA3026C3: 2.5 tons, 26 in. wide, paired with the GZV7SA2410A. One step up if your home is a little bigger.
- CHPEA3626B3 and CHPEA3626C3: 3 tons, 26 in., same refrigerant and same EEV expansion valve.
- CAHEA3630C3: 2 to 5 tons, only 21 in. wide, with three pairings published by the manufacturer.
- CHPEA4830C3, CHPEA4830D3, CHPEA6030C3 and CHPEA6030D3: 4 and 5 tons, 30 in., for much larger homes.
The CHPEA2422B3 is therefore the smallest in capacity, with the GZV6SA1810A as its only published partner. Its 22 in. width is the only one in the series that is neither 21 in., nor 26 in., nor 30 in.
Summary spec sheet
- type: cased evaporator coil, CHPEA line;
- refrigerant: R-32, EEV expansion device;
- connections: 5/16 or 3/8 in. on the liquid side, 5/8 or 3/4 in. on the suction side;
- leak detection: R-32 sensor designed to last the life of the coil (data sheet SS-DCoil-R32);
- warranty: 10-year limited parts warranty; online registration within 60 days of installation is not required in Quebec (Goodman data sheet SS-GCoil-R32).
Why switch to a heat pump instead of baseboards
Ordinary electric heating gives as much heat as the electricity it uses, no more, no less. A heat pump moves heat that is already present outdoors: in mild weather, it returns two to three times as much. As the cold sets in, that advantage shrinks, and that is precisely why the furnace stays in place. For a small home, the gain shows up quickly on the Hydro-Québec bill, and in summer, air conditioning comes as a bonus.
Goodman is part of Daikin Comfort Technologies, like Daikin and Amana. Its R-32 pairings with the GZV6SA, GZV7SA and GZV9SA heat pumps are ENERGY STAR and cold-climate certified, on a Goodman MBVK modular blower.
Three questions we often get
Can it provide heat? Yes, as long as it is paired with a heat pump. With an ordinary central air conditioner, it only cools.
Can I keep my current air conditioner? Generally not. The coil runs on R-32 and must connect to the outdoor unit the manufacturer intends for it: we therefore install the complete system.
Is my furnace still useful? Yes. It keeps its blower and takes over when the outdoor temperature falls below the threshold we program together.
AirGreen, your heating and cooling installer in Greater Montreal
A family-owned company based in Montreal for more than fifteen years, AirGreen carries out its refrigeration, ventilation and electrical work under RBQ licence 5645-9605-01. For this coil, we do the following:
- a survey of the furnace, the blower and the electrical panel;
- mounting the cabinet in the plenum, with an insulated transition if needed and sealed duct joints;
- installing the outdoor unit, brazing the piping, the nitrogen test and the vacuum;
- the condensate drain and the thermostat;
- startup, airflow balancing and a full explanation of how everything works.
Points to validate before buying
- The outdoor unit must use R-32 and be installed at the same time as the coil.
- The ratings shown are those of the certified pairing set out by the manufacturer.
- The furnace width, its blower and the available height are confirmed at your home.
LogisVert subsidy
The paired Goodman system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check the official list when we prepare your quote and fill out the application with you.
Get a written quote
Ask for a free in-home estimate: we measure the furnace, assess the electrical service and give you a clear quote for the complete Goodman system. Financing helps spread the cost over time.
The heat pump coil for your furnace
The CHPEA2422B3 sits in the plenum of a furnace or air handler. Connected to the Goodman GZV6SA1810A outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Goodman GZV6SA1810A outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 22 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.