YORK CTM36B5ADS1 Evaporator A-Coil | 3 Tons
The York CTM36B5ADS1 3-ton R-454B cased coil sits on your furnace and, matched with the York HH824E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCTM36B5ADS1
514 316-2973 · sales@airgreen.ca
Quick facts
CTM36B5ADS1: the 17-1/2 in York coil and its certified match
Of the 3-ton York coils we install, the CTM36B5ADS1 is the one whose match sheet shows the highest ratings in its series. The system it forms with the HH824E2S11 outdoor unit carries AHRI number 216010725, with a SEER2 and HSPF2 of 19.0 / 9.5. It is a cased A-coil, 17-1/2 in wide, that runs on R-454B refrigerant. It is mostly of interest to homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore who have a gas, oil or electric furnace in good condition and want to add air conditioning, or even heat pump heating.
What this model does in your home
An evaporator coil is the heat exchanger that sits in the plenum, right above the furnace. Air from the house passes through it, gives up its heat to the refrigerant circulating in the tubes, then goes back out through the vents, cooled. Without it, the outdoor unit is useless: it is the indoor half of the circuit.
The CTM36B5ADS1 belongs to York's CTM range. Its nominal size is 3 tons, or 36,000 BTU/h. It is a multi-position model: it can be mounted upflow, downflow or horizontal, left or right, which leaves some room to work with depending on where your furnace is installed.
Reading the AHRI number before you sign a quote
Here is a detail few people know: a coil has no efficiency rating on its own. Ratings belong to a pair, one specific coil and one specific outdoor unit, and the AHRI number is what links them. For this model, the number to keep is 216010725. It matches the York HH824E2S11 outdoor unit, an LX series heat pump on R-454B with a variable-speed compressor.
When you compare two quotes, ask each contractor for this number. Two prices can look equivalent when one describes a certified match and the other an assembly of parts whose ratings nobody guarantees. With us, the number is on the quote, and we check it in the directory before ordering.
- Cooling for the match: 23,000 BTU/h;
- heating at 47 °F: 23,000 BTU/h;
- SEER2 / HSPF2: 19.0 / 9.5.
A slim size for compact furnaces
At 17-1/2 in wide, the CTM36B5ADS1 is aimed at modest-sized furnaces, the kind found in a laundry room, a small basement or a blower cabinet squeezed between two walls. Its full dimensions are 17-1/2 × 25-5/8 in, and it weighs 50 lb net. A narrower coil slides into a tight space more easily, but it still has to match the plenum opening.
If your furnace is wider, we build an insulated transition on site. This is not a makeshift repair: it is a routine job, done with the same care as the rest of the installation, and sealing the connections is part of the work.
How to choose between this model and its three siblings
The series has four 3-ton models, all cased, all on R-454B and all with a TXV metering device. What sets them apart comes down to two things: the width and the outdoor unit.
- CTM36B5ADS1, the one on this page: 17-1/2 in, matched to the HH824E2S11 unit;
- CTM36B5CDS1: also 17-1/2 in, but matched to the HH836E2S11 unit;
- CTM36C5ADS1: 21 in wide, with no outdoor unit specified in our file;
- CTM36C5CDS1: 21 in wide, matched to the HH836E2S11 unit.
The rule is simple. First measure the width of your plenum: 17-1/2 in or 21 in. Only then discuss the match with the outdoor unit. If the width of your furnace points you toward 17-1/2 in, the question becomes: HH824E2S11 or HH836E2S11? We go over it on site, with the ratings of each in front of us.
What the furnace keeps, what it gives up
On a system like this, the furnace does not go away. It keeps its blower, its filters and the existing ductwork. In summer, the blower pushes air through the coil and the house cools down. In winter, if the outdoor unit is a heat pump, the cycle reverses and the refrigerant brings heat to the air; the furnace only takes over when the outdoor temperature drops below the threshold we set with you.
In practice, you can turn an electric furnace into a central heat pump, replace an old central air conditioner with a new system, or keep your furnace as backup heat for the coldest days. In all three cases, the coil sits in the same place and does the same job.
A refrigerant leak can be detected
R-454B belongs to the A2L family of refrigerants, which call for special monitoring. York has therefore built in a factory-installed A2L sensor (code S) on the coil plate. It is wired to the RDS control board: above 15% of the LFL, the call to the compressor is cut and the indoor fan is switched on to circulate the air. It is a passive safeguard that you do not have to manage, but it is good to know it exists.
Technical specifications at a glance
- Manufacturer: York, CTM range;
- type: cased evaporator coil;
- nominal size: 3 tons (36,000 BTU/h);
- refrigerant: R-454B;
- metering device: TXV;
- nominal airflow: 1,200 CFM;
- liquid connection: 3/8 in; suction connection: 3/4 in;
- dimensions W × H × D: 17-1/2 × 25-5/8 in;
- net weight: 50 lb;
- warranty: 10-year limited parts warranty.
Airflow deserves a word. York publishes about 350 to 450 CFM per ton of the outdoor unit, with an external static pressure of 0.2 to 0.6 in. W.C. This means your blower and ductwork must be able to deliver that volume of air. That is exactly what we check at the visit.
What we do on installation day
AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For this coil and its outdoor unit, here is how it goes:
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, with a transition built on site if needed, and sealing the duct connections;
- installing the outdoor unit on a pad or bracket, brazed piping, nitrogen leak test and vacuum;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment and a walk-through of how it works at your home.
The liquid line for the match is 3/8 in; for long distances between the outdoor unit and the coil, larger lines may be required, and we include that in the quote.
Five checks before you order
- The coil uses R-454B: the outdoor unit must use the same refrigerant and be installed at the same time.
- The published ratings apply to the certified match with the outdoor unit specified by the manufacturer.
- The 17-1/2 in width must suit your furnace.
- The blower must deliver the system's airflow.
- Your old air conditioner generally cannot be reused: it does not work with this refrigerant.
LogisVert subsidy
The matched York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it against the official list when we prepare the quote and put the application together with you, so you know what to expect before you say yes.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CTM36B5ADS1 sits in the plenum of a furnace or air handler. Connected to the York HH824E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the York HH824E2S11 outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
YORKSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton York coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.