YORK CTM36C5CDS1 Evaporator A-Coil | 3 Tons
The York CTM36C5CDS1 3-ton R-454B cased coil sits on your furnace and, matched with the York HH836E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCTM36C5CDS1
514 316-2973 · sales@airgreen.ca
Quick facts
Timeline of a project with the York CTM36C5CDS1 coil: 21 in wide, AHRI 214606576
Here is, step by step, how a project built around the CTM36C5CDS1 unfolds: a cased 3-ton York A-coil, 21 in wide, on R-454B refrigerant. It is matched to the HH836E2S11 outdoor unit and the system carries AHRI number 214606576. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, for homeowners whose furnace has some width to it.
Step one: the visit and the measurements
It all starts at your home. We measure the width of the plenum, look at the space available above the furnace, check the blower and take a look at the electrical panel. This coil measures 21 × 27 in and weighs 58 lb net; if your furnace is not quite that wide, we build an insulated transition on site.
At the end of the visit, you receive a written quote for the complete York system, with the AHRI number of the match. You can compare it, calmly, with any other.
Step two: understanding your ratings
The coil alone has no efficiency rating. Ratings belong to the certified system, and here are those of the CTM36C5CDS1 match with the HH836E2S11 unit:
- AHRI number: 214606576;
- cooling: 33,400 BTU/h;
- heating at 47 °F: 31,800 BTU/h;
- SEER2 / HSPF2: 15.2 / 8.5.
York states that most matches of its HH8 units with a coil alone are cold-climate certified. The coil on this page is not among the exceptions the manufacturer flags; we still check the match sheet when we prepare the quote.
Step three: choosing among the four siblings
Four 3-ton models make up the series, all cased, on R-454B and with a TXV metering device.
- CTM36B5ADS1: 17-1/2 in, HH824E2S11 unit;
- CTM36B5CDS1: 17-1/2 in, HH836E2S11 unit;
- CTM36C5ADS1: 21 in, no unit listed in our file;
- CTM36C5CDS1: 21 in, HH836E2S11 unit, the one on this page.
The CTM36C5CDS1 is for you if your furnace is 21 in wide and you want a match that is already certified, with a file number you can verify. The CTM36B5CDS1 shares the same outdoor unit in a narrower size. The CTM36C5ADS1 shares the width, but its match is decided at the visit.
Step four: installation day
AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. The day goes like this:
- installing the coil in the plenum, with sealing of the duct connections;
- installing the outdoor unit on a pad or bracket;
- brazed piping, nitrogen leak test, then vacuum;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment and explanation of how it works.
The liquid line is 3/8 in, and the suction line is 3/4 in. Over a long distance, larger lines may be required; we factor that into the price.
What the coil does behind the panel
Air from the house rises into the plenum and passes through the coil. The refrigerant evaporating in the tubes picks up its heat; the air comes out cooler, and the condensation water is carried away by the drain. With a heat pump, in winter, the exchange is reversed: the coil releases the heat that the outdoor unit went to collect outside. The TXV metering device regulates the flow of refrigerant sent into the coil.
It installs upflow, downflow or horizontal, left or right, which covers most basement layouts.
A2L sensor and safety
Because R-454B belongs to the A2L class, York mounts a factory sensor (code S) on the coil plate. It communicates with the RDS control board. When the 15% LFL threshold is exceeded, the compressor is no longer called on and the indoor fan starts. No adjustment is required from the homeowner.
CTM36C5CDS1 specifications
- Manufacturer: York, CTM range;
- type: cased evaporator coil;
- size: 3 tons (36,000 BTU/h);
- refrigerant: R-454B;
- nominal airflow: 1,200 CFM;
- dimensions W × H × D: 21 × 27 in;
- net weight: 58 lb;
- warranty: 10-year limited parts warranty.
On the air side, York indicates about 350 to 450 CFM per ton of the outdoor unit, with an external static pressure of 0.2 to 0.6 in. W.C. Your blower must be able to keep up.
What you keep from the old system
The furnace keeps its blower, its filters and its ductwork. It becomes backup heat when the outdoor temperature drops below the threshold we set with you. Your old air conditioner, on the other hand, generally cannot be reused: R-454B calls for an outdoor unit with the same refrigerant, installed along with the coil.
Neighbours' questions
Can it also heat? Yes, when it is matched to a heat pump, as it is here with the HH836E2S11 unit: it cools in summer and heats in winter. With a simple central air conditioner, it would only cool.
What if my furnace is not the same width? We measure it and, if needed, build an insulated transition on site. It is routine work, and the seal is checked as on the rest of the installation.
Is the furnace still useful? Yes. It keeps its blower, and it takes over when the cold goes beyond what the heat pump should handle alone.
Is it suited to a large house? The nominal size of 3 tons, or 36,000 BTU/h, suits many bungalows and cottages in Greater Montreal. We confirm the capacity choice at the visit rather than assuming it over the phone.
Why York
YORK is a residential equipment brand of Johnson Controls, distributed in Quebec by Groupe Master. It makes central heat pumps, furnaces and matching coils; the R-454B coils in the CTM range include the A2L sensor and the leak detection control required for this refrigerant. Having the same manufacturer on both sides of the circuit simplifies the match and the reading of the documentation.
After commissioning
Once the system is running, we show you the thermostat, the seasonal settings and where to change the filter. You leave with an accepted quote, an AHRI number in hand and the assurance that the coil, the outdoor unit and the furnace were tuned together. If you have a question later, you know who to call.
To check before choosing
- The outdoor unit must use the same refrigerant.
- The ratings apply to the match with the HH836E2S11 unit.
- The furnace width and blower must be suitable.
LogisVert subsidy
The matched York system appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation; we check it against the official list at the quote and prepare the application with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CTM36C5CDS1 sits in the plenum of a furnace or air handler. Connected to the York HH836E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the York HH836E2S11 outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
YORKSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton York coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.