YORK CTM36B5CDS1 Evaporator A-Coil | 3 Tons
The York CTM36B5CDS1 3-ton R-454B cased coil sits on your furnace and, matched with the York HH836E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCTM36B5CDS1
514 316-2973 · sales@airgreen.ca
Quick facts
3-ton York coil CTM36B5CDS1: the narrow size matched to the HH836E2S11 unit
The CTM36B5CDS1 is a cased A-coil, 17-1/2 in wide, that York designs for small furnaces. In our catalogue, it is the narrow option that connects to the HH836E2S11 outdoor unit. Like all its siblings, it uses R-454B refrigerant. We install it for homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore, in homes where the space around the furnace is unforgiving.
Upfront honesty about the ratings
It is better to say it right away: this match is not the one with the highest ratings in the series. The certified system carries AHRI number 214606513 and publishes a SEER2 and HSPF2 of 15.2 / 8.1, with 32,800 BTU/h of cooling and 31,000 BTU/h of heating at 47 °F. York also states that most matches of its HH8 units are cold-climate certified, but this one is not (HSPF2 8.1).
Is that a flaw? Not necessarily. It means this system suits someone looking first for air conditioning, or who keeps their furnace running actively during the coldest weather, better than someone counting on the heat pump to carry the winter alone. We would rather you know before the quote than in January.
The plenum decides everything
Before the price, before the brand, even before the capacity, there is one measurement: the width of your plenum. The CTM36B5CDS1 is 17-1/2 in wide and 25-5/8 in high, and its net weight is 50 lb. If your furnace is this width, the coil goes in without a detour. If it is wider, we build an insulated transition on site. If it is wider by a good margin, a 21 in model may make sense, and we discuss that below.
The coil comes in multiple positions: upflow, downflow, horizontal left or right. A low-ceiling basement, where the furnace lies on its side, is therefore not ruled out.
Our place in the series: four models, two widths
All models in the series are 3 tons (36,000 BTU/h), cased, on R-454B and with a TXV metering device. So you choose between them on the basis of two criteria.
- 17-1/2 in width: CTM36B5ADS1, matched to the HH824E2S11 unit, and the CTM36B5CDS1 on this page, matched to the HH836E2S11 unit;
- 21 in width: CTM36C5ADS1, with no unit specified in our file, and CTM36C5CDS1, also matched to the HH836E2S11 unit.
The CTM36B5CDS1 and the CTM36C5CDS1 therefore share the same outdoor unit; only the width of the cabinet changes. If your furnace is narrow, you are on the B5 side. If it is wide, look at the C5 side. Finally, the CTM36B5ADS1 shares our narrow width, but it pairs with the other outdoor unit, the HH824E2S11.
What the coil does, without the jargon
Think of a radiator in reverse. Cold refrigerant flows through aluminum and copper tubes; warm air from the house passes between the fins, gives up its heat and comes out cooler. Moisture in the air condenses on the fins, drops into the pan and drains away through the condensate drain. That is why an air-conditioned house feels not only cooler but also drier.
With a heat pump, the cycle can reverse in winter and heat from outside is carried indoors. The furnace stays ready to take over below the threshold we set with you.
R-454B refrigerant safety
R-454B is an A2L class refrigerant. For this reason, this coil ships with a factory-installed A2L sensor (code S), attached to the coil plate and wired to the RDS control board. If the concentration exceeds 15% of the LFL, the call to the compressor is cut and the indoor fan starts. You have nothing to adjust.
CTM36B5CDS1 specifications
- Brand and range: York, CTM;
- type: cased evaporator coil;
- nominal capacity: 3 tons, or 36,000 BTU/h;
- refrigerant: R-454B;
- metering device: TXV;
- nominal airflow: 1,200 CFM;
- connections: 3/8 in for liquid, 3/4 in for suction;
- dimensions W × H × D: 17-1/2 × 25-5/8 in;
- net weight: 50 lb;
- warranty: 10-year limited parts warranty.
Questions we often hear
Can this coil provide heat? Yes, when it is matched to a heat pump: it cools in summer and heats in winter. With a central air conditioner, it only cools.
Can I keep my current air conditioner? Generally not. The coil runs on R-454B and must be matched to the outdoor unit specified by the manufacturer. We install the complete system.
Is the furnace still useful? Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the threshold we set with you. It also keeps its filters and ductwork.
Is my airflow sufficient? York indicates about 350 to 450 CFM per ton of the outdoor unit, with an external static pressure of 0.2 to 0.6 in. W.C. We measure it at the visit.
A typical installation day
AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For this system, we proceed as follows:
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, custom transition if needed, and sealing the duct connections;
- outdoor unit on a pad or bracket, brazed piping, nitrogen test and vacuum;
- connecting the drain and the thermostat;
- commissioning, airflow adjustment and a walk-through at your home.
The liquid line is 3/8 in; over a long distance, larger lines may be needed, which we include in the quote.
What kind of home is it for?
Think of the small suburban bungalow, the ground floor of a duplex or the cottage whose furnace is wedged into a narrow cabinet: these are the homes where a 17-1/2 in coil naturally fits. An electric furnace you want to turn into a central heat pump, an old central air conditioner to replace, or window units you are tired of: the starting point changes, but the logic stays the same. We measure, we match, we install the complete system, and we tune the whole thing so the house behaves well in both seasons.
To check before choosing
- The outdoor unit must use the same refrigerant, R-454B, and be installed at the same time.
- The ratings apply to the certified match, not to the coil alone.
- The furnace must offer the right width and blower.
- If heating is your priority, talk to us and compare the matches.
LogisVert subsidy
The matched York system appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation; we confirm it against the official list when we prepare the quote and put the application together with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CTM36B5CDS1 sits in the plenum of a furnace or air handler. Connected to the York HH836E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the York HH836E2S11 outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
YORKSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton York coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.