YORK CTM42C5CES1 Evaporator A-Coil | 3.5 Tons

In stock

The York CTM42C5CES1 3.5-ton R-454B cased coil sits on your furnace and, matched with a matching York outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCTM42C5CES1

3.5 tons42,000 BTU/h nominal
21 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCTM42C5CES1
ManufacturerYork
Size3.5 tons
Width21 in
RefrigerantR-454B
MeteringTXV

York CTM42C5CES1: the 3.5-ton cased coil, a slim 21 in wide, for the furnace in a mid-size home

You are looking at the page for the York CTM42C5CES1 coil because a quote, a technician or your own research brought you to this model number. Here is what you need to know before saying yes: what this part does, what it asks of your furnace, what it cannot do on its own, and how we install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

In two sentences

It is a finned heat exchanger, mounted in an insulated cabinet, that sits on top of the furnace. It receives R-454B refrigerant from the outdoor unit and draws the cooling (or, with a heat pump, the heating) that the blower then sends through your ductwork.

3.5 tons: what size of home is it for?

The nominal size is 3.5 tons, or 42,000 BTU/h. In the CTM range we are looking at here, it is the smallest of the three models, and it is also the one that asks the least of the blower. It suits a well-insulated bungalow, a semi-detached home or a two-storey house with rooms of ordinary size. For a very large two-storey home, or a house with many windows poorly shielded from the afternoon sun, the question of moving up to the next size comes up.

We never settle this choice at a glance. During the visit, we assess the home's heat loss and heat gain, then compare the result with the coil size. A unit that is too big keeps shutting off and restarting, which leaves the air humid; a unit that is too small never catches up with a July heat wave.

The 21 in width, your first check

This model measures 21 in wide and 28-3/4 in high. That width is the same as the CTM48C5CFS1, but narrower than the CTM48D5CFS1. Why does it matter? Because the cabinet sits directly on the furnace, and the two must line up so that air passes through without leaks.

When the furnace is wider or narrower, that is no reason to give up on the project. We measure the plenum and, where needed, build an insulated transition cut on site. It is routine sheet-metal work in our installations.

Choosing between the three models in the series

Here is how we present the series to a customer who is undecided, sticking to the published data:

  • CTM42C5CES1 (this page): 3.5 tons, 21 in wide, TXV, R-454B;
  • CTM48C5CFS1: 4 tons, also 21 in wide, TXV, R-454B, with a published match to the HH836E2S11 outdoor unit;
  • CTM48D5CFS1: 4 tons, but 24-1/2 in wide, TXV, R-454B.

The reading is simple. If your furnace is 21 in wide and the home is mid-size, the CTM42C5CES1 is the natural candidate. If your cooling needs go up a notch, the CTM48C5CFS1 keeps the same footprint. If your furnace cabinet is wider, the CTM48D5CFS1 saves us from building a transition. All three are cased, use the same refrigerant and have the same metering device: the difference comes down to size and width.

What the TXV does inside the cabinet

The metering device on this coil is a TXV, a thermostatic expansion valve. It doses the liquid refrigerant entering the tubes according to the heat actually absorbed at the outlet. The result: the coil works with the right amount of refrigerant, whether the day is mild or sweltering. It is a component you will never see, but its precise adjustment is part of commissioning.

Where it goes: upflow, downflow, horizontal

The manufacturer publishes this coil as multi-position: upflow, downflow, horizontal left or right. In other words, it follows the furnace, whether the furnace blows upward in a basement, downward in an attic or sideways in a crawl space. An A shape, with two sloped faces that meet at the top, adapts to these positions thanks to its condensate pan.

The pan collects the water the coil pulls from the humid summer air and directs it to the drain. We connect this drain with care, because poor drainage is the classic cause of water damage near a furnace.

A heat pump on a furnace: how it works in your home

The CTM42C5CES1 does not heat on its own. Paired with a York heat pump of the same capacity, it becomes the indoor half of a system that cools in summer and heats in winter. With a simple central air conditioner, you only get cooling.

The furnace does not go away. It keeps its blower, its filters and its ductwork. When the outdoor air gets too cold for the heat pump to be enough, the furnace takes over, at a threshold we program with you. If your current heating is electric, adding a heat pump reduces the share of heat produced by pure resistance: in mild temperatures, the heat pump delivers two to three times more heat than the electricity it consumes.

R-454B and the built-in safety

The coil runs on R-454B refrigerant, rated A2L. For that reason, York factory-mounts a leak sensor (code S) on the coil plate, connected to the RDS control board. If the detected level exceeds 15% of the LFL, the call to the compressor is cut and the indoor fan starts to circulate the air. This protection is a requirement of the refrigerant, and there is nothing for you to adjust.

Practical consequence: the coil is matched with an outdoor unit that uses the same refrigerant, and the two are installed together. Keeping your old air conditioner is therefore generally not possible.

Spec sheet, in plain language

  • Manufacturer and range: York, CTM series, model CTM42C5CES1;
  • Type: cased evaporator coil;
  • Nominal size: 3.5 tons, or 42,000 BTU/h;
  • Dimensions (W × H): 21 × 28-3/4 in;
  • Net weight: 62 lb, which is easy to handle on a plenum;
  • Connections: liquid 3/8 in, suction 7/8 in;
  • Nominal airflow: 1,400 CFM;
  • Manufacturer's warranty: 10-year limited parts warranty (YORK brochure PUBL-8373-B-0324).

Airflow: the blower's job

A coil, even a perfectly chosen one, gives poor results if the blower does not push enough air through it. Before ordering, we check the blower's capacity, the plenum space and the condition of the return air. A clogged filter or a return that is too narrow costs you in comfort and noise.

Efficiency ratings: read the AHRI number

This coil has no efficiency rating of its own. The published ratings belong to the matched, certified system. Before placing an order, we confirm the AHRI number of the match, so that the figures in your quote are the ones you will actually get. If you are comparing two offers, ask each contractor for this number.

Rebates and LogisVert

Eligibility for rebates, including those under LogisVert and Hydro-Québec, depends on the complete system and not on the coil alone. We check the official list at the time of the quote, based on the installation date, and we tell you clearly what applies to your project.

Our installation, step by step

AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, and our work is done under RBQ licence 5645-9605-01. For this coil and its outdoor unit, the visit and the installation follow this order:

  • measuring the furnace, checking the blower and the electrical panel;
  • setting the cabinet on the plenum, custom transition if needed, sealing the duct connections;
  • outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum;
  • connecting the condensate drain and the thermostat;
  • commissioning, airflow adjustment and a walkthrough at the house.

Questions we are often asked

Can I keep my current air conditioner? Generally no: the coil is designed for R-454B and for the outdoor unit specified by the manufacturer. We install the complete system.

Is my furnace still useful? Yes, it serves as backup heating for the coldest days.

Is the coil alone eligible? No, eligibility is judged on the matched system.

Next step: an on-site estimate

Request your free estimate: we come to your home, measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CTM42C5CES1 sits in the plenum of a furnace or air handler. Connected to a matching York outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching York outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
ModelCTM42C5CES1
TypeCased evaporator coil
LineCTM
Nominal size3.5 tons (42,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Airflow1,400 CFM
Dimensions W × H × D21 × 28-3/4 in
Net weight62 lb
Model numberCTM42C5CES1
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
YORK
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3.5-ton York coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.