YORK CTM48C5CFS1 Evaporator A-Coil | 4 Tons

In stock

The York CTM48C5CFS1 4-ton R-454B cased coil sits on your furnace and, matched with the York HH836E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCTM48C5CFS1

4 tons48,000 BTU/h nominal
21 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 214606575
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCTM48C5CFS1
ManufacturerYork
Size4 tons
Width21 in
RefrigerantR-454B
MeteringTXV
Outdoor unitHH836E2S11

York CTM48C5CFS1: a 4-ton coil whose certified HH836E2S11 match is already published

Some coils arrive with no numbers to back them up; this one has its own. The York CTM48C5CFS1 is a 4-ton cased coil, 21 in wide, with a named outdoor partner: the HH836E2S11 heat pump. This pair has a published AHRI number, capacities and ratings. This page helps you read those figures and check that the part suits your furnace, whether you live in Montreal, Laval, Longueuil, on the North Shore or on the South Shore.

Reading the system sheet: the numbers that matter

Taken together, the CTM48C5CFS1 and the HH836E2S11 outdoor unit form a system certified under AHRI number 214606575. The published values are:

  • cooling: 31,600 BTU/h;
  • heating: 30,800 BTU/h at 47 °F;
  • system ratings: SEER2 / HSPF2 of 15.2 / 8.5.

These ratings describe the whole assembly, not the coil on its own. When a quote promises you a SEER2 or an HSPF2, ask for the AHRI number: it is what proves the two parts were tested together. Yours is this one.

Why talk about 4 tons when the published capacity is lower?

The coil's nominal size is 4 tons, or 48,000 BTU/h. The capacities of the matched system, for their part, come from the chosen outdoor unit and the test conditions. This is a normal distinction in the industry: the coil is sized to allow a comfortable airflow, while the system's capacity comes from the complete match. If this point puzzles you, ask about it during the visit; we will show you in the AHRI directory.

21 in wide, a cabinet 33 in high

The dimensions (W × H) are 21 × 33 in, with a net weight of 73 lb. The assembly installs on an upflow furnace, but also in downflow or horizontal, left or right, since York publishes it as multi-position. The shape is that of an A: two sloped faces that meet, with air passing through them as it rises from the furnace.

The cabinet is insulated and delivered ready to install, which saves us from improvising an enclosure on site. The 21 in width has to match the furnace cabinet; if not, we build an insulated transition.

Compared with its two neighbours in the series

To know whether you are in the right place, compare three spec sheets:

  • CTM42C5CES1: 3.5 tons, 21 in, TXV, R-454B; the smallest size in the series, with no named outdoor unit;
  • CTM48C5CFS1 (this page): 4 tons, 21 in, TXV, R-454B, with the HH836E2S11 unit already matched;
  • CTM48D5CFS1: 4 tons, 24-1/2 in, TXV, R-454B, for a wider furnace cabinet.

The CTM48C5CFS1 is therefore the right choice if your furnace is 21 in wide and the home needs more than the 3.5-ton offers. Its one distinguishing feature on paper is the certified match that can be cited by number. If your furnace is wider, the D saves the transition.

What the coil actually does

Think of a radiator placed in the home's airstream. In summer, the refrigerant evaporates in its tubes, absorbs heat from the passing air and carries it outside; the condensed water drops into a pan connected to the drain, which also dries the indoor air. In winter, with a heat pump, the cycle reverses and the coil gives up to the air the heat captured by the outdoor unit.

The furnace, with its blower, filters and ductwork, stays where it is. It takes over when the cold goes beyond what the heat pump can reasonably supply, at the threshold we set with you.

The TXV and the A2L sensor

A thermostatic expansion valve (TXV) modulates the refrigerant supply according to the load. R-454B, for its part, is an A2L refrigerant: York therefore factory-installs a sensor mounted on the coil plate and connected to the RDS control board. Above 15% of the LFL, the call to the compressor is interrupted and the indoor fan switches on. Both devices are standard; all you have to do is entrust their setup to a competent installer.

Full technical data

  • model: CTM48C5CFS1, York CTM range;
  • type: cased evaporator coil;
  • nominal size: 4 tons (48,000 BTU/h);
  • refrigerant: R-454B;
  • 3/8 in liquid connection and 7/8 in suction connection;
  • nominal airflow: 1,600 CFM;
  • 10-year limited parts warranty, per YORK brochure PUBL-8373-B-0324;
  • reference manual for leak detection: 6356510-UIM-C-0824.

Blower, plenum, returns: the checks that come before the order

An airflow of 1,600 CFM requires a blower able to deliver it without struggling. A clogged filter or a restricted return can freeze the coil or leave rooms lukewarm. At the visit, we inspect the blower, measure the plenum and examine the returns before confirming that this model is the right one.

One basic rule to add: the coil is matched with an outdoor unit that runs on the same refrigerant, installed at the same time. Keeping an old air conditioner is therefore generally not an option.

Comparing two quotes without getting lost

A serious quote names the coil, the outdoor unit and the AHRI number. If any of the three is missing, you cannot verify what you are being offered. With the CTM48C5CFS1 and the HH836E2S11, the check takes a few minutes: you enter the number in the directory and read the same figures as the ones in this text.

Also ask who handles the vacuum, the leak test and the airflow adjustment. These steps cannot be seen once the walls are closed up, but they decide the system's lifespan. With us, they are included in the work and recorded in the file.

Finally, look at the warranty: the manufacturer's is limited to 10 years on parts, per the brochure cited above. It covers parts, not labour, which is why choosing an established installer in Montreal or its surrounding area matters as much as choosing the equipment.

LogisVert rebate

The York system matched this way appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation; we do not state it in advance. We validate it on the official list at the time of the quote and put together the LogisVert application with you.

How we install

AirGreen, a family-run heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. For this complete system, the usual sequence is:

  • measuring the furnace and checking the blower and the electrical panel;
  • installing the cabinet in the plenum, custom transition if necessary, sealed duct connections;
  • setting the outdoor unit, brazed piping, nitrogen test, vacuum;
  • condensate drain and thermostat connected;
  • commissioning, airflow adjustment and explanations given on site.

Frequently asked questions

Does this coil heat? Yes, if it is paired with a heat pump; with a central air conditioner, it only cools.

My furnace is not 21 in wide. So what? We measure and build an insulated transition if needed.

Does my furnace become useless? No, it keeps its backup role in extreme cold.

Getting your quote

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CTM48C5CFS1 sits in the plenum of a furnace or air handler. Connected to the York HH836E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the York HH836E2S11 outdoor unit
Certified systemMatched with the HH836E2S11, the system carries AHRI 214606575.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
ModelCTM48C5CFS1
TypeCased evaporator coil
LineCTM
Nominal size4 tons (48,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Airflow1,600 CFM
Dimensions W × H × D21 × 33 in
Net weight73 lb
Matched outdoor unitHH836E2S11
System AHRI number214606575
System SEER2 / HSPF215.2 / 8.5
Model numberCTM48C5CFS1
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
YORK
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 4-ton York coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.