YORK CTM48D5CFS1 Evaporator A-Coil | 4 Tons

In stock

The York CTM48D5CFS1 4-ton R-454B cased coil sits on your furnace and, matched with a matching York outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCTM48D5CFS1

4 tons48,000 BTU/h nominal
24-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCTM48D5CFS1
ManufacturerYork
Size4 tons
Width24-1/2 in
RefrigerantR-454B
MeteringTXV

York CTM48D5CFS1: a 4-ton coil in a 24-1/2 in wide cabinet for larger furnaces

In York's CTM series, the CTM48D5CFS1 is the one you choose when the furnace is wide. At 24-1/2 in, this 4-ton cased coil takes up more space than its two neighbours, but it fits large cabinets better with no tinkering. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, most often in two-storey homes or large bungalows.

Visit day: what we measure first

When we arrive at a customer's home who is considering this model, the first thing we take out is a tape measure. We record the width of the furnace cabinet, the height available above the plenum and the room around it to work. The coil measures 24-1/2 × 32-3/4 in; it therefore has to fit on the furnace without touching the ceiling or blocking access to the filter.

Next come the blower and the return air. The nominal airflow is 1,600 CFM, and the blower must sustain it without straining. A return that is too narrow shows up as noise, uneven rooms and, in the worst case, a coil covered in frost.

Why 24-1/2 in rather than 21 in?

The series comes in two widths. Here are the three spec sheets side by side:

  • CTM42C5CES1: 3.5 tons, 21 in, TXV, R-454B;
  • CTM48C5CFS1: 4 tons, 21 in, TXV, R-454B, published match with the HH836E2S11 unit;
  • CTM48D5CFS1 (this one): 4 tons, 24-1/2 in, TXV, R-454B.

If your furnace cabinet measures 24-1/2 in or close to it, this model saves us from connecting a transition piece. If your furnace is narrower, the CTM48C5CFS1 gives the same nominal capacity in a slimmer size. And if the home is modest, the CTM42C5CES1 may be enough. Note that, for the D, no specific outdoor unit is named in our data: we confirm the match and its AHRI number before ordering.

An 80 lb unit: plan for handling

The net weight is 80 lb. That is not excessive, but it is enough that we plan for two people when the plenum is up high, above a basement furnace with a narrow staircase. The cabinet is insulated and ready to install, which cuts time on site and improves the seal between the furnace and the coil.

The A shape and the possible positions

Two sloped faces, joined at the top, form the letter A. Air from the furnace passes through both faces before heading to the ductwork. York publishes this model as multi-position: upflow, downflow, horizontal left or right. Whether your furnace blows up, down or flat, there is a configuration.

What a coil does in a real home

Picture a suburban two-storey home, with an upstairs bedroom that overheats in August while the living room stays cool. A properly sized coil, combined with an adequate blower and ductwork in good condition, distributes the air better. It does not fix everything: if the upstairs ducts are poorly insulated or unbalanced, we say so and propose corrections.

In summer, the coil cools and dries the air. In winter, with a heat pump, it releases the heat captured outside. The furnace then keeps a backup role for the coldest days, at a threshold we program with you.

A large cabinet: does that also mean an older furnace?

Not necessarily, but it happens. Many large electric furnaces in North Shore and South Shore homes have a generous cabinet, built to house big heating elements and a sturdy blower. That space is an asset: it easily accepts a 24-1/2 in cabinet and leaves room for the piping connections, which we braze with care.

If the furnace is old, we take the opportunity to examine the condition of the blower, the filter and the neighbouring ducts. It is better to know before installing than to find out about an insufficient return air on the first day of a heat wave. And if a part of the system deserves replacing, we tell you frankly, with the options.

One last job-site detail: the condensate drain. On a model of this size, the amount of water collected in summer can be significant on humid days. We plan a drain run that slopes down clearly and can be inspected, rather than hiding it behind a wall.

Manufacturer specifications

  • model CTM48D5CFS1, CTM series, York;
  • cased evaporator coil, TXV metering device;
  • 4 tons, or 48,000 BTU/h;
  • W × H dimensions of 24-1/2 × 32-3/4 in;
  • net weight of 80 lb;
  • 3/8 in (liquid) and 7/8 in (suction) connections;
  • R-454B refrigerant;
  • 10-year limited parts warranty (YORK brochure PUBL-8373-B-0324).

R-454B refrigerant and its leak sensor

R-454B is rated A2L. York therefore factory-mounts a sensor (code S) on the coil plate, connected to the RDS control board. When the concentration exceeds 15% of the LFL, the call to the compressor is cut and the indoor fan is started (manual 6356510-UIM-C-0824). It is a built-in protection, with no adjustment on your part.

Since the coil requires the same refrigerant as the outdoor unit, both must be replaced together. Your old air conditioner generally cannot be kept.

Efficiency ratings: what to know

The coil has no efficiency rating of its own; the published ratings belong to the matched system. We confirm the AHRI number before purchase, then write it into the quote, so that you can compare equivalent offers.

Rebates

Hydro-Québec programs, including LogisVert, judge eligibility on the complete system, never on the coil alone. We check the official list on the date of the quote and tell you what applies to your file.

Our work, start to finish

AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01. A typical installation includes:

  • measuring the furnace, the blower and the electrical panel;
  • setting the cabinet on the plenum, with sealed duct connections;
  • installing the outdoor unit, brazed piping, nitrogen test and vacuum;
  • connecting the condensate drain and the thermostat;
  • commissioning, airflow adjustment and a walkthrough.

Quick answers

Can this model heat? Yes, with a heat pump. With a central air conditioner, it only cools.

What if my furnace is narrower? We build an insulated transition on site.

Is the furnace still used? Yes, as backup when it gets very cold outside.

Let's work out the numbers for your home

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CTM48D5CFS1 sits in the plenum of a furnace or air handler. Connected to a matching York outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching York outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
ModelCTM48D5CFS1
TypeCased evaporator coil
LineCTM
Nominal size4 tons (48,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Airflow1,600 CFM
Dimensions W × H × D24-1/2 × 32-3/4 in
Net weight80 lb
Model numberCTM48D5CFS1
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 24-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
YORK
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 4-ton York coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.