YORK CTM60C5CHS1 Evaporator A-Coil | 5 Tons

In stock

The York CTM60C5CHS1 5-ton R-454B cased coil sits on your furnace and, matched with the York HH860E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCTM60C5CHS1

5 tons60,000 BTU/h nominal
21 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 214606530
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCTM60C5CHS1
ManufacturerYork
Size5 tons
Width21 in
RefrigerantR-454B
MeteringTXV
Outdoor unitHH860E2S11

CTM60C5CHS1: a York 5-ton coil, 21 in wide by 39 in tall

When a furnace is narrow but the plenum offers some height, the York CTM60C5CHS1 coil comes into play. It shares the 21 in width of the CTM60C5CGS1, but its cabinet is 39 in tall and its net weight reaches 78 lb. It is a small air-handling detail that changes the job-site visit, and we explain it here without jargon.

Our team installs this type of coil in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, mostly in homes where electric heating or an old central air conditioner is giving way to a heat pump.

Vertical clearance, the first question of the visit

With published dimensions of 21 × 39 in (width × height), this cabinet needs room above the furnace. We therefore measure the space between the top of the unit and the ceiling of the mechanical room, as well as the path of the supply plenum. If a few inches are missing, we adapt the transition rather than sacrifice access to the filter or the drain.

If your furnace has a different width, we build an insulated transition on site; this is a common job and does not force you to change your furnace.

One coil, one cabinet, a promise of simplicity

The CTM60C5CHS1 is a cased coil. Everything is factory-mounted: the coil, its insulated enclosure, and its 3/8 in (liquid) and 7/8 in (suction) connections. On site, the installation comes down to connecting, sealing and checking. The metering device is a TXV, and the coil accepts several positions: upflow, downflow, horizontal left or right.

A single published pairing: the HH860E2S11

Unlike some of its siblings, this coil is published with a single York outdoor unit, the HH860E2S11. The AHRI number of the system is 214606530. Its ratings are SEER2 15.2, HSPF2 8.1.

This heating rating belongs to the complete system, not to the coil itself. It serves as an honest benchmark when you compare: an HSPF2 figure only means something when it comes with the right AHRI number.

How does it compare with the other coils in the series?

All the models in the group are York 5-ton coils using R-454B, with a TXV, paired with the HH860E2S11. Here is how to tell the CTM60C5CHS1 apart.

  • Against the CTM60C5CGS1: same 21 in width. The latter is published with two outdoor units, whereas the CHS1 has only one. Look at the cabinet height your room allows before deciding.
  • Against the CTM60D5CGS1, CTM60D5CHS1 and CTM60D5CJS1: these three are 24-1/2 in wide. If your furnace is narrower, they call for a more generous transition.
  • On ratings: each model has its own AHRI number. Ours is 214606530; always confirm it in the quote.

What the coil changes day to day

In summer, the heat and humidity of the indoor air are captured by the coil and the water runs off to the drain. The cool air comes out of the same vents that used to carry the heating. You no longer buy a window air conditioner for each bedroom.

In winter, with the heat pump, the cycle reverses. The furnace stays there, with its blower, its filters and its heating elements. It takes over when the outdoor temperature falls below the threshold we set with you, which protects you against deep cold without making the heat pump struggle.

The A2L sensor, in two sentences

R-454B is an A2L refrigerant. York installs a sensor (code S) at the factory on the coil plate, wired to the RDS control board. Above 15% of the LFL, the compressor stops receiving its call and the indoor fan starts. The manufacturer's installation manual, reference 6356510-UIM-C-0824, details how this works.

Three scenarios where the CTM60C5CHS1 makes sense

The electric furnace you want to keep. Many homeowners on the South Shore or in Laval have an electric furnace that still works. Adding the heat pump and this coil avoids replacing everything: the cost is concentrated on the outdoor unit and the coil, and the furnace moves into a backup role.

The old central air conditioner at the end of its life. If the original compressor is near the end, replacing the whole set with an R-454B system makes more sense than repairing old equipment whose refrigerant is getting harder to find.

The addition that made the house too big for its system. After an extension or a finished basement, the original capacity no longer keeps up. The 5-ton size answers that need, provided the ductwork can deliver the airflow.

Summary spec sheet

  • model: CTM60C5CHS1, CTM series;
  • nominal size: 5 tons, 60,000 BTU/h;
  • refrigerant: R-454B;
  • dimensions (W × H × D): 21 × 39 in;
  • net weight: 78 lb;
  • nominal airflow: 1,800 CFM;
  • warranty: 10-year limited parts warranty (YORK brochure PUBL-8373-B-0324).

Why put a 5-ton system in your home

The 5-ton size suits large homes, finished basements and extensions. At this size, the electrical entrance and the airflow become the two points to validate. We sometimes recommend two smaller systems rather than one big one; we would rather tell you at the visit than after the installation.

York, a Johnson Controls brand distributed in Quebec by Groupe Master, builds into its CTF, CTM and CTU coils using R-454B the leak-detection sensor and control that this refrigerant requires. The HH8 heat pumps are variable-speed and ENERGY STAR certified for Canada and the United States.

The AirGreen installation, step by step

A family-owned heating and cooling company based in Montreal for more than fifteen years, AirGreen works under RBQ licence 5645-9605-01. Here is how the job unfolds:

  • measuring the furnace, the blower and the electrical panel;
  • installing the coil in the plenum and sealing the joints;
  • outdoor unit on a pad or bracket, brazed line set, nitrogen test, evacuation;
  • condensate drain and thermostat;
  • commissioning, airflow adjustment and explanations in your home.

Year-round comfort, seen from the inside

A well-tuned central system makes itself forgotten, and that is a good sign. Rooms even out, the thermostat controls a single installation, and the treated air circulates through the vents you already know. In the warm season, the air sheds its moisture; in the cold season, the heat arrives through the same grilles, without the surges of an electric baseboard heater switching on and off.

Points to confirm before ordering

  • The height available for a 39 in cabinet.
  • The width of the furnace compared with the 21 in of the coil.
  • A pairing with an R-454B outdoor unit, installed at the same time as the coil.
  • The ability of the blower to deliver the airflow of the system.

LogisVert subsidy

The paired York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your file: we check it against the official list at the time of the quote and prepare the application with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete York system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CTM60C5CHS1 sits in the plenum of a furnace or air handler. Connected to the York HH860E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the York HH860E2S11 outdoor unit
Certified systemMatched with the HH860E2S11, the system carries AHRI 214606530.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
ModelCTM60C5CHS1
TypeCased evaporator coil
LineCTM
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Airflow1,800 CFM
Dimensions W × H × D21 × 39 in
Net weight78 lb
Matched outdoor unitHH860E2S11
System AHRI number214606530
System SEER2 / HSPF215.2 / 8.1
Model numberCTM60C5CHS1
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
YORK
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton York coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.