YORK CTM60D5CHS1 Evaporator A-Coil | 5 Tons

In stock

The York CTM60D5CHS1 5-ton R-454B cased coil sits on your furnace and, matched with the York HH860E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCTM60D5CHS1

5 tons60,000 BTU/h nominal
24-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 214606582
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCTM60D5CHS1
ManufacturerYork
Size5 tons
Width24-1/2 in
RefrigerantR-454B
MeteringTXV
Outdoor unitHH860E2S11

The York CTM60D5CHS1: a 24-1/2 in by 39 in cabinet, up close

In this series of five York 5-ton coils, the CTM60D5CHS1 is the one whose cabinet measures 24-1/2 in wide by 39 in tall. Its net weight of 84 lb makes it a two-person lift. If your project is in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, here is how a typical day with this model unfolds, from measuring to start-up.

Before the visit: what you can prepare

Clear access to the furnace and the electrical panel, locate the supply plenum and note the brand of your unit. A photo of the nameplate saves us time. We bring the rest: tape, level, measuring tools and knowledge of the type of coil that goes in there.

First hour: measuring

We record the width of the furnace (the cabinet is 24-1/2 in), the clear height above it (the cabinet is 39 in) and the layout of the connections. The coil is multiposition: upflow, downflow, horizontal left or right; we choose the orientation that suits your room. If the width does not match, we prepare an insulated transition on site.

Second step: validating the electricity and the air

The panel must be able to power the York HH860E2S11 outdoor unit. As for the air, the blower must deliver the nominal airflow of 1,800 CFM targeted by the system. We do not sign a quote without making these two checks, because they determine whether the 5-ton size is realistic in your home.

The certified system: one pairing, one number

The CTM60D5CHS1 is published with the HH860E2S11. The AHRI number of the system is 214606582, with SEER2 15.2, HSPF2 8.1. These ratings describe the coil and outdoor unit together. The coil alone has none, and this number is the reference to quote if you compare two quotes.

How this model ranks against the other four

  • 24-1/2 in width: shared with the CTM60D5CGS1 and CTM60D5CJS1 models.
  • 21 in width: the CTM60C5CGS1 and CTM60C5CHS1 are narrower.
  • Outdoor unit: here, only one is published, the HH860E2S11, as for the CTM60D5CJS1. The CTM60D5CGS1 lists two.
  • Constants: York, 5 tons, R-454B, TXV, insulated cabinet.

The simple version: if your furnace is wide and the room allows 39 in of height, it easily takes its place among the candidates.

Third step: the installation

We install the cabinet in the plenum, seal the duct connections and check that it is level so the condensate flows toward the drain. Next comes the outdoor unit: pad or bracket, brazed line set, nitrogen pressure test, then evacuation. The coil connections are 3/8 in on the liquid side and 7/8 in on the suction side.

Fourth step: the A2L sensor and commissioning

R-454B is classified A2L. For that reason, York installs a sensor (code S) at the factory on the coil plate and wires it to the RDS control board. Above 15% of the LFL, the compressor no longer receives a call and the indoor fan starts. We test this logic at commissioning, then adjust the airflow, connect the thermostat and show you how to use it.

What you keep from your installation

The blower, the filters and the existing ducts remain. The furnace stays useful: it provides backup heat when the outdoor temperature drops below the threshold programmed with you. An old air conditioner, however, cannot be paired with this coil: R-454B requires an outdoor unit using the same refrigerant, specified by the manufacturer.

After start-up: what to watch

During the first weeks, check that water drains properly, that the vents deliver steady air and that the thermostat stays stable. Replace the filters on the schedule we give you: a clogged filter reduces airflow, and the coil suffers first. If anything seems abnormal, call us: a quick check often avoids a bigger repair.

Also keep the AHRI number 214606582 of your system. It identifies your set to the manufacturer, to us and to subsidy programs.

Why such a large coil, and when not to choose it

A 5-ton size suits a home that demands a lot of cooling, with a large volume to treat. It is not right for every property. Tight vertical clearance, an undersized blower or a fully loaded electrical panel are all reasons to rethink the project. We say so at the visit, before you commit a single dollar.

What it can do for your comfort

In summer, it cools and dries the air, and the drain carries off the condensation. In winter, with a heat pump, it delivers the heat collected outdoors. The YORK HH8 heat pump is variable-speed and ENERGY STAR certified for Canada and the United States. The manufacturer describes it as an LX series heat pump using R-454B.

Three neighbours' questions

Is it noisy? The coil itself makes no noise; the air passing through it is that of your current blower. The noise you perceive comes mostly from the duct network and the air speed, which we adjust at commissioning.

Do walls need to be opened? No, the piping between the outdoor unit and the coil goes through a discreet opening, and the ducts stay where they are.

How long does the job take? It depends on the house and the length of the piping. We give you an estimate at the visit and we keep to the agreed schedule.

Spec sheet data to keep handy

  • model: CTM60D5CHS1, CTM series, cased coil;
  • nominal size: 5 tons (60,000 BTU/h);
  • dimensions (W × H × D): 24-1/2 × 39 in;
  • warranty: 10-year limited parts warranty (YORK brochure PUBL-8373-B-0324);
  • installation manual: 6356510-UIM-C-0824.

Who comes to your home

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01. York, a Johnson Controls brand distributed in Quebec by Groupe Master, makes central heat pumps, furnaces and matching coils; its CTF, CTM and CTU coils using R-454B include the required leak sensor.

To check before placing the order

  • Enough clearance for 39 in of height.
  • A furnace wide enough for 24-1/2 in, or a transition to plan for.
  • An R-454B outdoor unit, installed with the coil.
  • An adequate electrical entrance.

LogisVert subsidy

The paired York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation: we confirm it against the official list at the time of the quote and put the file together with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete York system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CTM60D5CHS1 sits in the plenum of a furnace or air handler. Connected to the York HH860E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the York HH860E2S11 outdoor unit
Certified systemMatched with the HH860E2S11, the system carries AHRI 214606582.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerYork
ModelCTM60D5CHS1
TypeCased evaporator coil
LineCTM
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Airflow1,800 CFM
Dimensions W × H × D24-1/2 × 39 in
Net weight84 lb
Matched outdoor unitHH860E2S11
System AHRI number214606582
System SEER2 / HSPF215.2 / 8.1
Model numberCTM60D5CHS1
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 24-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
YORK
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton York coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.