YORK CTM60D5CJS1 Evaporator A-Coil | 5 Tons
The York CTM60D5CJS1 5-ton R-454B cased coil sits on your furnace and, matched with the York HH860E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCTM60D5CJS1
514 316-2973 · sales@airgreen.ca
Quick facts
CTM60D5CJS1: how to read the quote for a York 5-ton coil
Two quotes on the table, two lists of numbers that look alike. The York CTM60D5CJS1 coil, a 5-ton R-454B cabinet 24-1/2 in wide, deserves to have you learn how to read what you are being offered. This guide is for homeowners in Montreal, Laval, Longueuil, on the North Shore and on the South Shore who want to compare methodically.
First point: the exact model
CTM60D5CJS1: the CTM series, the 5-ton size (60,000 BTU/h), a specific cabinet version. A neighbouring coil with a different letter at the end is not necessarily identical: weight, height or pairing can vary. Here, the published dimensions are 24-1/2 × 37-1/4 in and the net weight is 83 lb.
Second point: the AHRI number
This is the most important one. For this coil paired with the York HH860E2S11 unit, the number is 214606519, and the system ratings are SEER2 15.2, HSPF2 8.5. A different number designates a different set. The ratings belong to the system and not to the coil: if a quote shows no number, ask for it.
Third point: the outdoor unit
The CTM60D5CJS1 is published with a single unit, the HH860E2S11, a York R-454B heat pump with a variable-speed compressor, certified ENERGY STAR for Canada and the United States. A coil cannot be paired with just any air conditioner: the refrigerant must be the same, and the whole set is installed in one go.
Fourth point: the metering device
This model uses a TXV. This small component doses the refrigerant at the coil inlet according to the load. In a serious quote, it is mentioned; if it is missing, ask the question.
Fifth point: the width of the furnace
The coil is 24-1/2 in wide. We check the furnace before ordering, and if the width differs, we build an insulated transition on site. A quote that mentions neither a measurement nor a transition deserves a second look.
Should you prefer it over its four neighbours?
It belongs to a series of five York 5-ton coils using R-454B, with a TXV, all associated with the HH860E2S11.
- Same 24-1/2 in width: CTM60D5CGS1 and CTM60D5CHS1.
- Narrower, at 21 in: CTM60C5CGS1 and CTM60C5CHS1.
- A single published outdoor unit for this model, as for the CTM60D5CHS1; the CTM60C5CGS1 and CTM60D5CGS1 have two.
If your furnace matches 24-1/2 in and you are aiming for the HH860E2S11, you are squarely in this model's territory. For the rest, the comparison is made by AHRI number.
Sixth point: what stays in your home
The blower, the filters and the existing ducts are kept. The furnace becomes backup heat below the temperature threshold we set with you. The coil does not reuse an old air conditioner: R-454B requires the manufacturer's outdoor unit.
Seventh point: the warranty and the documentation
The manufacturer's warranty is a 10-year limited parts warranty, per YORK brochure PUBL-8373-B-0324. The reference installation manual is 6356510-UIM-C-0824. Keep these numbers: they help when a technician needs to find the right documentation.
Three common mistakes when comparing
Comparing ratings without an AHRI number. A SEER2 or HSPF2 shown without a certification number proves nothing. It may come from another pairing, or even another coil.
Forgetting that the furnace works too. The coil adds resistance to the passage of air. The blower must be able to overcome it while delivering the airflow of the system. We check this point during the visit and we adjust the airflow at commissioning.
Thinking that bigger is always better. A 5-ton size is meant for large homes. In an average home, it would be too much; we prefer to say so and propose a smaller size or two systems.
Two home profiles where it makes sense
The large electric furnace. A homeowner in Laval or on the North Shore whose electric furnace is still sound can keep it as backup and benefit from a heat pump for most of the season. The coil is the link that makes this combination possible.
The central air conditioner to replace. In a home in Longueuil or Montreal whose old air conditioner is giving up, this new system replaces the whole set at once and avoids repairing equipment whose parts are getting scarce.
In both cases, we measure before proposing, and we give you a written quote that states the model, the AHRI number and the outdoor unit.
What the coil does, in concrete terms
In an add-on system, it fits into the plenum, in the path of the air. In summer, the refrigerant evaporates in the tubes and captures heat; the condensation water is collected in the pan. In winter, with a heat pump, the cycle reverses and the heat is delivered to the air of the house. It accepts several positions: upflow, downflow, horizontal left or right.
Built-in leak detection
Because R-454B is an A2L refrigerant, York installs a sensor at the factory (code S) on the coil plate, wired to the RDS board. Above 15% of the LFL, the call to the compressor is cut and the indoor fan is started. Connections: 3/8 in liquid, 7/8 in suction. Nominal airflow: 1,800 CFM.
A word on the comfort you will get from it
With a central system, a single outdoor unit serves the whole house. Cool air circulates in every room through the existing ducts, humidity drops and July heat becomes more bearable. In the cold season, the heat pump provides most of the heating and the furnace stays ready for deep cold. A single thermostat controls both seasons, which simplifies daily life.
Our work in your home
AirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01. The project follows five steps:
- measurements of the furnace, the blower and the panel;
- installing the coil in the plenum and sealing the connections;
- outdoor unit, brazed line set, nitrogen test, evacuation;
- condensate drain and thermostat;
- commissioning, airflow adjustment and explanations.
York is a Johnson Controls brand, distributed in Quebec by Groupe Master.
To check before you buy
- The AHRI number 214606519 written on the quote.
- R-454B on both sides of the system.
- The width of the furnace and the capacity of the blower.
- The electrical entrance for the outdoor unit.
LogisVert subsidy
The paired York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your file: we check it against the official list at the time of the quote and prepare the application with you. Eligibility is tied to the complete system.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete York system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CTM60D5CJS1 sits in the plenum of a furnace or air handler. Connected to the York HH860E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the York HH860E2S11 outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 24-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
YORKSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 5-ton York coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.