ZEPHYR DC37D3J Evaporator A-Coil | 3 Tons
The Zephyr DC37D3J 3-ton R-454B cased coil sits on your furnace and, matched with the Zephyr ZE-636HPA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberDC37D3J
514 316-2973 · sales@airgreen.ca
Quick facts
From the first call to commissioning: the DC37D3J, a 3-ton Zephyr evaporator coil
Many homeowners write to us with the same message: "I have a furnace in the basement, an old air conditioner that is running out of breath, and I would like to understand what is ahead." This page therefore follows the course of a real project with the Zephyr DC37D3J evaporator coil, a cased model of 3 tons (36,000 BTU/h) on R-454B refrigerant, A-shaped, from the DC line.
It connects to the Zephyr ZE-636HPA outdoor unit. We work in Montreal, Laval, Longueuil, the North Shore and the South Shore.
Step one: the conversation about the house
The 3-ton size sits in the middle of the line, and that is often where suburban bungalows and cottages end up: furnace in the basement, ducts to every room, and window units that come back every July. Before we suggest this coil, we ask simple questions. What is the heated floor area? Where is the kitchen? Is there a finished floor under the roof?
Only then do we confirm the size. The DC37D3J is not our automatic answer; it is one of the four options in the line.
Step two: choosing among the four coils
All cased DC models share R-454B refrigerant and the TXV R-454B (J) metering device. What varies:
- DC31D2J: 2 tons, ZE-624HPA unit, for small volumes;
- DC37D3J: 3 tons, ZE-636HPA unit, the model on this page;
- DC49B3J: 4 tons, 21 in wide, ZE-648HPA unit;
- DC61C4J: 5 tons, 24-1/2 in wide, ZE-660HPA unit.
The manufacturer's publication gives no width for the two smallest, so we take the furnace measurements ourselves. If your home leans toward the top of the range, look at the two models above; if it is more compact, the 2-ton may be enough.
Step three: the certified match
The DC37D3J coil is published with the ZE-636HPA outdoor unit, under AHRI number 218160014. As published by Zephyr, this system delivers 34,000 BTU/h of cooling and 34,000 BTU/h of heating at 47 °F, with 16.5 SEER2 and 8.2 HSPF2.
Bear in mind that the coil has no efficiency rating on its own. The ratings belong to the certified pair. When comparing two offers, ask for each one's AHRI number.
Zephyr states that its matched outdoor units use a continuously variable speed compressor and R-454B, whose global warming potential is 470.
Why the 3-ton comes up so often
In the bungalow neighbourhoods of Laval, Longueuil or the North Shore, the setup repeats: an upflow furnace, ductwork already in place, a single thermostat. For these homes, adding a coil on the furnace is a measured job that requires no wall openings and no new duct runs.
Comfort also comes from consistency. One blower distributes cool or warm air to every room, including those where a wall unit would never be installed: the bedroom at the end of the hall, the basement office, the playroom. You avoid the gaps between the upper floor and the basement that irritate occupants so much.
Step four: the dimensions and connections to know
- type: evaporator coil with insulated cabinet;
- net weight of 51 lb, which is easy to handle on a basement staircase;
- liquid line 3/8 in ODS, suction line 3/4 in ODS;
- condensate drain 3/4 in NPT;
- upflow installation by default, downflow with the DWNFLWP-175 kit purchased separately.
The manufacturer does not publish a width for this model here. That is one more reason to measure at your home rather than assume.
What we ask you to prepare
To make the visit efficient, clear access to the furnace, locate your electrical panel and keep an old electricity bill handy if you have one. Also note the rooms that are too hot or too cold in summer; those clues guide the airflow setting. No other preparation is required from you.
Step five: A2L refrigerant safety
With an A2L class refrigerant, a detection device is mandatory. Aspen offers the A2LZS and A2LZR kits; the second includes a relay. They can be mounted at the factory or on site, and the RBL list includes the A2LZR. We choose with you the kit that suits your installation.
Step six: what happens on installation day
AirGreen is a family-owned heating and cooling company based in Montreal. On installation day, we:
- check the furnace, the blower and the electrical panel;
- set the coil in the plenum, with a custom-built transition if needed, and seal the air duct connections;
- secure the outdoor unit, braze the piping, run the nitrogen leak test and pull a vacuum;
- connect the drain and the thermostat;
- start the system, set the airflow and give you a demonstration.
What the coil does, in practice
Placed in the plenum, it intercepts the air leaving the blower. In summer, the refrigerant evaporates inside it, absorbs heat and the air heads to the rooms cooler; the condensation runs into the pan, then into the drain. In winter, with a heat pump, the direction is reversed and the coil gives up heat to the air.
The furnace keeps its blower, its filters and its backup role for very cold nights. The switchover threshold is programmed with you.
And on the electricity bill?
Conventional electric heating produces as much heat as the electricity it uses. A heat pump moves heat instead of making it: in mild weather, it delivers two to three times more heat than the energy it takes in. That efficiency drops with the cold, which justifies the furnace as backup. In summer, a single system replaces window units, dries the air and is controlled from one place.
Before you sign
- the coil is matched with an outdoor unit using the same refrigerant; the two are installed together;
- the current air conditioner is generally not kept;
- we measure the furnace before ordering, and build an insulated transition if the widths differ;
- the blower must be able to supply the system's airflow.
LogisVert rebate
The matched system must appear on the official Hydro-Québec list; eligibility applies to the complete system and not to the coil alone. The amount depends on the installation date and on your file. We check the list at the time of the quote and prepare the application with you. The coil itself benefits from a 10-year limited warranty offered by Aspen, with registration.
After commissioning
A well-installed system needs little attention: a clean filter, a clear pan and drain, and an outdoor unit kept free of snow and leaves. We give you these instructions in writing, and we remain available to adjust the setting if a room behaves differently than expected in the first heat wave or the first deep freeze.
Taking action
Request your free on-site estimate: we measure the furnace, check the electrical service and write up a quote for the complete Zephyr system. Financing helps you spread the expense.
The heat pump coil for your furnace
The DC37D3J sits in the plenum of a furnace or air handler. Connected to the Zephyr ZE-636HPA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Zephyr ZE-636HPA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- We check the furnace width before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
ZEPHYRSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Zephyr coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.