ZEPHYR DC49B3J Evaporator A-Coil | 4 Tons
The Zephyr DC49B3J 4-ton R-454B cased coil sits on your furnace and, matched with the Zephyr ZE-648HPA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberDC49B3J
514 316-2973 · sales@airgreen.ca
Quick facts
Zephyr DC49B3J 4-ton coil: 21 in wide, to be measured before anything else
With a coil this size, the first question is not "how many tons?" but "will it fit on my furnace?" The DC49B3J is a Zephyr cased evaporator coil of 4 tons (48,000 BTU/h) on R-454B refrigerant. It measures 21 in wide by 24 in high and 21-1/2 in deep. Set on the furnace and connected to the ZE-648HPA outdoor unit, it cools the house and, with a heat pump, heats it as well.
We install it in Montreal, Laval, Longueuil, the North Shore and the South Shore.
Width: the detail that decides the installation
The 21 in cabinet must sit over the opening of your furnace plenum. If the two widths match, installation is straightforward. If they differ, we build an insulated transition on site that joins the two sections cleanly, with no air leaks or thermal bridge.
That is why we always measure before ordering. A mistake of a few inches means a delay, sometimes unplanned sheet metal work. A set of measurements taken at the visit costs less than that.
- published dimensions (W × H × D): 21 × 24 × 21-1/2 in;
- net weight: 51 lb;
- condensate drain: 3/4 in NPT;
- liquid connection: 3/8 in ODS; suction connection: 7/8 in ODS.
Note the suction connection is larger than on the 2- and 3-ton models (3/4 in ODS). A 4-ton coil circulates more refrigerant, and the piping follows.
Four tons: for what type of home?
This is a size for large homes with a furnace, those with many rooms to cool, a finished basement or an older addition connected to the same air system. At this level, airflow matters as much as capacity: a weak blower or narrow ducts will limit the result, however good the coil.
So during the visit we check the blower, the condition of the ducts and the capacity of the electrical service. If another size suits better, we say so clearly.
Airflow: the quiet partner of capacity
A coil of this size is only worth it if air can pass through it in sufficient quantity. In an older home, the ducts have sometimes been adjusted over the course of renovations: a narrowed branch, a tight elbow, a closed damper in a room that is rarely used. These details go unnoticed with heating alone, but they show up as soon as air conditioning is added.
During the visit, we look over the system, note the rooms that receive less air and suggest useful corrections. The final airflow setting is done at commissioning, when everything is connected and we can measure the real result in the house.
Placing it in the DC line
Four cased coils, same refrigerant, same TXV R-454B (J) metering device:
- DC31D2J: 2 tons, ZE-624HPA unit;
- DC37D3J: 3 tons, ZE-636HPA unit;
- DC49B3J: 4 tons, 21 in wide, ZE-648HPA unit, this one;
- DC61C4J: 5 tons, 24-1/2 in wide, ZE-660HPA unit.
Between the DC49B3J and the DC61C4J, the difference is twofold: a larger size and a wider cabinet. If your furnace is narrow, the first will be easier to fit. If the house needs a lot of cooling and the furnace is wide, it is worth comparing with the second. The 2- and 3-ton models suit more modest volumes.
The certified pair: ZE-648HPA
Zephyr publishes this match under AHRI number 218160015: 48,000 BTU/h of cooling, 48,000 BTU/h of heating at 47 °F, 16.5 SEER2 and 8.3 HSPF2. Only the pair carries a rating. The coil has none on its own, and the AHRI number is what lets you compare quotes honestly.
The matched outdoor units use a continuously variable speed compressor and R-454B, with a global warming potential of 470.
How the air becomes cool
The blower pushes air into the plenum; it passes through the coil fins, where the liquid refrigerant evaporates and absorbs heat. The condensation water runs into the pan and leaves through the drain. In heating mode with a heat pump, the hot refrigerant coming from the outdoor unit gives up its heat to the air passing through. For the coldest days, the furnace takes over, at a threshold we set with you.
A2L refrigerant and detection
R-454B belongs to the A2L class. A refrigerant detection system (RDS) is therefore required. Aspen supplies the A2LZS and A2LZR kits, the second with a relay, which can be mounted at the factory or on site; the RBL list mentions the A2LZR. The coil is installed in the upflow position, or in the downflow position with the DWNFLWP-175 kit sold separately.
Where it goes in the house
In most cases, the furnace is in the basement or in a utility room. The cabinet goes right above it, so the 24 in height must fit between the top of the furnace and the ceiling or joists. We check this clearance, as well as the space needed to change the filters and reach the drain later.
How our job unfolds
AirGreen, a heating and cooling company in Montreal, proceeds as follows:
- survey of the furnace, blower check, a look at the electrical panel;
- installation of the cabinet in the plenum, custom transition if needed, sealing of the joints;
- installation of the outdoor unit, brazing, nitrogen pressure test and vacuum;
- connection of the drain and the thermostat;
- commissioning, airflow balancing and explanations.
Heat pump or air conditioner only?
With an air conditioner, the coil only cools. With a heat pump, it works all year. An electric heater converts one kilowatt-hour into the same amount of heat; the heat pump moves heat and supplies two to three times more in mild weather. That ratio shrinks when it is very cold, which is why the furnace is kept as backup.
For a large home, the difference shows mostly in summer, when a single outdoor unit replaces several window units.
What to confirm before buying
- the refrigerant must be the same for the coil and the outdoor unit;
- the old air conditioner generally cannot be kept;
- the furnace must accommodate a 21 in width, otherwise we prepare a transition;
- the blower must supply the required airflow.
LogisVert rebate
Hydro-Québec assesses the complete system, not the coil on its own. We check its official list according to the installation date and prepare the file with you; the amount depends on your situation. The coil is covered by a 10-year limited warranty, offered by Aspen with registration.
Why Zephyr and Aspen
Zephyr offers wall-mounted and central heat pumps distributed in Quebec by TTI. Its R-454B central systems match a variable speed outdoor unit with an Aspen coil from the DC series. This combination is tested as a whole, and that is what makes it possible to obtain an AHRI number specific to each pair, and therefore ratings you can verify yourself.
Your on-site estimate
Request your free estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Zephyr system. Financing is available to spread the cost.
The heat pump coil for your furnace
The DC49B3J sits in the plenum of a furnace or air handler. Connected to the Zephyr ZE-648HPA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Zephyr ZE-648HPA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
ZEPHYRSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton Zephyr coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.