ZEPHYR DC61C4J Evaporator A-Coil | 5 Tons

In stock

The Zephyr DC61C4J 5-ton R-454B cased coil sits on your furnace and, matched with the Zephyr ZE-660HPA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberDC61C4J

5 tons60,000 BTU/h nominal
24-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 218160016
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberDC61C4J
ManufacturerZephyr
Size5 tons
Width24-1/2 in
RefrigerantR-454B
MeteringTXV R-454B (J)
Outdoor unitZE-660HPA

DC61C4J: a 5-ton Zephyr coil, 24-1/2 in wide, for a large home

The DC61C4J is the coil in the line that demands the most space and the most preparation. It is a Zephyr cased evaporator coil of 5 tons (60,000 BTU/h) on R-454B. Its published dimensions are 24-1/2 in wide, 32 in high and 21-1/2 in deep, with a net weight of 72 lb. It connects to the Zephyr ZE-660HPA outdoor unit.

We install it in Montreal, Laval, Longueuil, the North Shore and the South Shore, mostly in homes where the air system serves many rooms.

A house that has grown over the years

This size is for large properties, finished basements and homes expanded over time, where a single furnace has to serve a substantial volume. Each addition (sunroom, extra floor, converted garage) adds to the summer load, and that is the kind of situation where people turn to 5 tons.

Before going that high, we confirm that the real needs justify it. An oversized coil runs in short cycles and leaves the moisture in place; a size that fits is better than a size that impresses.

Capacity, electrical service and air distribution

Three elements must agree:

  • the capacity of the system, here 60,000 BTU/h nominal for the coil;
  • the electrical supply of the outdoor unit, which we check at the panel;
  • the air distribution, that is, a blower and ducts able to circulate the required volume.

If one of the three falls short, the result suffers. That is why the on-site estimate is free: it exists to answer these three questions before you commit.

Weight, height and access: the logistics of the DC61C4J

At 72 lb, this coil is the heaviest in the line; it takes two people to handle. Its 32 in height requires clearance above the furnace, which we measure at the visit. The insulated cabinet arrives ready to install, which limits the sheet metal work, but the staircase, the utility room door and a low ceiling can complicate handling.

  • liquid connection 3/8 in ODS, suction 7/8 in ODS;
  • condensate drain 3/4 in NPT;
  • TXV R-454B (J) metering device;
  • upflow position as standard; downflow with the DWNFLWP-175 kit, sold separately.

Choosing between the 5-ton and its neighbours

In the DC line, all cased coils use R-454B with the same metering device. The reference points for choosing:

  • DC31D2J (2 tons, ZE-624HPA) and DC37D3J (3 tons, ZE-636HPA): for small to medium-sized homes;
  • DC49B3J (4 tons, 21 in wide, ZE-648HPA): the step just below, with a narrower cabinet;
  • DC61C4J (5 tons, 24-1/2 in wide, ZE-660HPA): this one, for the largest volume to cool.

If your furnace is narrow or the room is tight, the 4-ton will often be simpler to install. If the house truly needs more capacity, the 5-ton is the answer, provided the furnace and blower keep up.

The certified system with the ZE-660HPA

The AHRI number of the match is 218160016. Zephyr publishes 54,000 BTU/h of cooling and 54,000 BTU/h of heating at 47 °F, and SEER2 / HSPF2 ratings of 16.4 / 8.2 for the system. These ratings describe the system, not the coil alone. The AHRI number is the best reference for comparing two quotes, and it is the one checked for the rebate.

The outdoor units in this group use a continuously variable speed compressor and a refrigerant with a global warming potential of 470.

What the coil does in the plenum

Air passes from the fan through the surfaces of the coil. In summer, the refrigerant evaporates in it and absorbs heat; the water that condenses is collected, then carried away by the drain. In winter, with a heat pump, the cycle is reversed and heat is transferred to the air of the rooms. The furnace keeps its filters and its blower, and it takes over according to the outdoor temperature threshold that we set together.

If the house is large, how do you spread the air?

The larger the volume, the more distribution matters. A large home often has rooms far from the furnace, at the end of a long duct, and those are the rooms that complain first about stifling heat. We examine the system, spot the branches that are too long or too narrow and suggest adjusting the registers or correcting the most limiting sections.

The airflow setting at commissioning is there for exactly this: to reach a balanced result between the upper floor, the main floor and the basement, without the blower being strained.

A2L refrigerant safety

A refrigerant detection system is required with A2L refrigerants such as R-454B. Aspen offers the A2LZS kit and the A2LZR kit, the latter with a relay; they can be mounted at the factory or on site, and the RBL list includes the A2LZR. We help you choose according to your installation.

Costing heating differently

In a large home, the heating bill is significant. Electric heating turns electricity into heat one for one; a heat pump, by contrast, moves heat and delivers two to three times more in mild weather. The efficiency decreases with the cold, which explains the furnace as backup. In summer, a single outdoor unit replaces a series of window units, and the drier air makes humid heat more bearable.

Our work, from survey to demonstration

AirGreen is a heating and cooling company based in Montreal. For the DC61C4J, we:

  • measure the furnace and the clearance, check the blower and the electrical panel;
  • install the cabinet in the plenum, with an insulated transition if needed, and seal the joints;
  • set the outdoor unit, braze the piping, test with nitrogen and pull a vacuum;
  • connect the condensate drain and the thermostat;
  • commission the system, adjust the airflow and explain how it works.

A word on maintenance

For a coil of this size, the regularity of checks matters more than their complexity.

A large coil collects dust like any other. A clean filter, a clear condensate pan and an outdoor unit free of snow and leaves protect the performance and the lifespan of the system. We give you simple instructions at the end of commissioning and we stay reachable for any question.

To confirm before ordering

  • the coil and the outdoor unit share the same refrigerant and are installed together;
  • the existing air conditioner generally cannot be reused;
  • the 24-1/2 in width must suit the furnace, otherwise a transition is built;
  • the blower must supply the system's airflow.

LogisVert rebate

Eligibility applies to the complete system. We check the official Hydro-Québec list on the date of the quote, and we put the file together with you; the amount depends on your situation. The coil benefits from a 10-year limited warranty offered by Aspen, with registration.

Requesting an estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and submit a written quote for the complete Zephyr system. Financing lets you spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The DC61C4J sits in the plenum of a furnace or air handler. Connected to the Zephyr ZE-660HPA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Zephyr ZE-660HPA outdoor unit
Certified systemMatched with the ZE-660HPA, the system carries AHRI 218160016.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerZephyr
ModelDC61C4J
TypeCased evaporator coil
LineDC
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV R-454B (J)
Liquid connection3/8 in ODS
Suction connection7/8 in ODS
Dimensions W × H × D24-1/2 × 32 × 21-1/2 in
Net weight72 lb
Matched outdoor unitZE-660HPA
System AHRI number218160016
System SEER2 / HSPF216.4 / 8.2
Model numberDC61C4J
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 24-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
ZEPHYR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton Zephyr coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.