3-Zone Heat Pump DURASTAR Standard | 60,000 BTU - R454B

In stock
SKU: DRA6U60M2A
60,000BTU/h · 3 heads
−25 °Cheats down to
Optional Wi-FiR-454BUp to 6 heads
Talk to a technician · 514 316-2973
Outdoor unit DRA6U60M2APossible indoor models DRAC0912F2A, DRAC18F2A, DRAC24F2A, DRADH0912F2A, DRADH18F2A, DRADH24F2A, DRADL0612F2A, DRADL18F2A, DRAF18F2A, DRAF24F2A, DRAL0612F2A, DRAL18F2A, DRAM18F2A, DRAM24F2A, DRAS09F2A, DRAS12F2A, DRAS16F2AAHRI 215359212
In short

The Durastar Standard R454B 60 000 multi-zone heat pump heats and cools 3 rooms with a single outdoor unit. it delivers 41,500 BTU/h at −8 °C, heats down to −25 °C. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

3 rooms, one outdoor unit.

Compared with the 19 multi-zone systems of 60,000 BTU we sell. Every number on this page carries its source.

NEEP 389549AHRI 215359212
+Heats down to −30 °CRank 1 (tied) of 19. Class median: −20 °C.
+Indoor head from 24 dB(A)Rank 1 (tied) of 19. Class median: 29 dB(A).
+Only 55 dB(A) outdoorsRank 1 (tied) of 19. Class median: 58 dB(A).
!Good to know: 41,500 BTU/h at −8 °CRank 15 of 19; class median: 42,000 BTU/h.
41,500BTU/h certified at −8 °C
−25 °Cstill heating
3 → 6heads, on the same unit
2.7COP at −8 °C
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

DRA6U60M2A

Outdoor unit

One compressor for the whole house. It supplies up to 6 heads and modulates from 20,000 to 41,500 BTU/h depending on what the rooms call for (NEEP).

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones6 zones
18,000BTU
23
28,000BTU
234
36,000BTU
2345
48,000BTU
23456
60,000BTU
2Here456

Durastar Standard R454B 60 000 · 3 zones

41,500 BTU/h
at −8 °C

Up to 6 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 60 % of its rated capacity.

Tap a temperature: certified capacity, efficiency and the cost of one hour of heating.

It slows down, it speeds up: the certified modulation range

Light bar: from minimum to maximum capacity. Dark mark: the rated value.

+8.3 °C
20,000 → 60,000 BTU/h
-8 °C
18,000 → 41,500 BTU/h
-15 °C
13,000 → 36,000 BTU/h
Source: NEEP, minimum, rated and maximum ratings at 47, 17 and 5 °F.
07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.

SEER2 · seasonal cooling19.2
Scale 1 – 30Median: 20.5
Rank 15 (tied) of 19 in its class.
HSPF2 · seasonal heating9.6
Scale 1 – 15Median: 10
Rank 15 (tied) of 19 in its class.
EER2 · cooling in peak heat10.0
Scale 1 – 20Median: 11.4
Rank 15 (tied) of 19 in its class.
COP at −15 °C2.0
Scale 0 – 4Median: 2.01
Rank 8 (tied) of 12 in its class.
09 · Report card

Where it ranks among same-size multi-zone systems.

Compared with the 19 multi-zone systems of 60,000 BTU we sell. Weaknesses too, said plainly.

10 · Head-to-head

Against three other brands in its class.

Same rated size, other manufacturers. Pick the opponent.

11 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone3 wall units
On the wall1 outdoor unit3 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVertPer the listDepends on each model

We compare both options on your floor plan during the estimate.

12 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

21.81 in
DRA6U60M2ADepth 12.99 in
31.69 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
15 A max. breaker
MCA 15 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 15 A, 15 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up.
13 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

24
43
55
29
58
20 dB(A)3040506070
24 Reference head, lowest speed43 Reference head, highest speed29 Class indoor median55 Outdoor unit58 Class outdoor median
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
14 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

20,000BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
−25 °CColdest certified pointNEEP still lists 27,600 BTU/h at a COP of 1.72 at −13 °F.
150 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
15 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)60,000 BTUSheet
Certified cooling at 35 °C60,000 BTU/hNEEP
SEER2 (seasonal cooling efficiency)19.2AHRI
EER2 (instant cooling efficiency)10.0AHRI
HSPF2 (seasonal heating efficiency, region IV)9.6AHRI
HSPF2, region V (coldest)7.3NEEP
Heating
Capacity at +8.3 °C60,000 BTU/h · COP 3.5NEEP
Capacity at −8 °C41,500 BTU/h · COP 2.7NEEP
Capacity at −15 °C36,000 BTU/h · COP 2.0NEEP
Capacity at -25 °C (max.)27,600 BTU/h · COP 1.72Sheet
Modulation range20,000 – 41,500 BTU/hNEEP
Heats down to−25 °CSheet
Zones and heads
Zones on this product3 Zones (Triple Zone)Sheet
Maximum zones6 ZonesSheet
Possible indoor modelsDRAC0912F2A, DRAC18F2A, DRAC24F2A, DRADH0912F2A, DRADH18F2A, DRADH24F2A, DRADL0612F2A, DRADL18F2A, DRAF18F2A, DRAF24F2A, DRAL0612F2A, DRAL18F2A, DRAM18F2A, DRAM24F2A, DRAS09F2A, DRAS12F2A, DRAS16F2ASheet
Indoor dimensions (W × D × H)22.44 x 22.44 x 9.65 inSheet
Vertical louversAutoSheet
Horizontal louversManuel / ManualSheet
Airflow (reference head)418 CFMSheet
Indoor sound (reference head)24 – 43 dB(A)Sheet
Installation
Outdoor unit (W × D × H)31.69 x 12.99 x 21.81 inSheet
Outdoor sound55 dB(A)Sheet
Base pan heater150 WNEEP
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)15 ASheet
MOP (maximum overcurrent protection)15 ASheet
RefrigerantR-454BSheet
Wi-FiOptionalSheet
Certifications and warranty
AHRI215359212AHRI
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
16 · Official brochures

The manufacturer’s documentation, as PDF.

17 · Description

Everything we have written about this system.

Une maison de campagne n'a aucun bruit ambiant pour couvrir celui d'un appareil

À Vaudreuil-Dorion, une maison occupée du vendredi soir au dimanche se juge la nuit. Il n'y a ni circulation ni voisin immédiat pour masquer quoi que ce soit, et le moindre ventilateur s'entend depuis la chambre. La réfection de la toiture a réglé l'étanchéité et remis la question du confort au premier plan. La Thermopompe 3-Zones DURASTAR Standard | 60 000 BTU - R454B répond à cette exigence avec des têtes dont la fiche inscrit 24 à 43 dB(A) et une unité extérieure donnée à 55 dB(A).

Ses cotes sont de 19,2 SEER2, 10,0 EER2 et 9,6 HSPF2, pour une capacité nominale de 60 000 BTU/h sur trois zones et une limite de chauffage de -30 °C.

Les paliers relevés sur ce châssis

  • À -8 °C : 41 500 BTU/h, avec un COP de 2,70
  • À -15 °C : 36 000 BTU/h, avec un COP de 2,00
  • À -25 °C : 27 600 BTU/h, avec un COP de 1,72
  • Limite de chauffage inscrite : -30 °C

Ces chiffres sont ceux du certificat AHRI 215359212, tels que publiés par le NEEP. Les 418 PCM, les 24 à 43 dB(A) et le boîtier de 22,44 x 22,44 x 9,65 po appartiennent à la tête que la fiche prend comme référence et non à chacune des trois têtes posées.

Le silence mesuré, à l'intérieur comme dehors

Le bas de la plage intérieure, 24 dB(A), correspond au régime de nuit, celui où la tête tourne au ralenti parce que la pièce est déjà à la consigne. Un appareil bien dimensionné y passe la plus grande partie d'une nuit d'été. Dehors, les 55 dB(A) se mesurent à l'unité, pas à la fenêtre : la distance et l'orientation du soufflage font le reste.

Le 0 $ du programme LogisVert, dit tout de suite

Ce système ne figure pas sur la liste des thermopompes admissibles au programme LogisVert d'Hydro-Québec en vigueur, ce qui explique la valeur de 0 $ affichée dans la fiche technique. Une résidence secondaire ne répond d'ailleurs pas toujours à la définition retenue par le programme. Nous vérifions quels formats voisins figurent sur la liste en vigueur à la date d'installation.

Vaudreuil-Dorion : ce qu'une maison ouverte deux jours sur sept demande à l'entretien

Soixante mille BTU/h à répartir sur trois zones

Les 60 000 BTU/h appartiennent au châssis DRA6U60M2A et se partagent entre les trois têtes selon la demande de chacune, jamais en parts figées. Une maison fermée cinq jours sur sept repart d'une température basse le vendredi soir : c'est la seule fois de la semaine où les trois zones appellent ensemble. Fermer une chambre inoccupée n'arrête pas les autres. Les ensembles publiés comprennent DRAM24F2A, DRAF24F2A, DRADH24F2A et DRAL18F2A ; le châssis en accepte six.

Les arrêts longs et les remises en route

  • Un délai de trois minutes au redémarrage protège le compresseur
  • De la vapeur blanche à l'unité extérieure accompagne un dégivrage
  • Des craquements du plastique suivent les écarts de température d'une remise en route

Une odeur de brûlé, un disjoncteur qui saute, un code d'erreur persistant ou de l'eau à l'intérieur demandent l'arrêt de l'appareil et un appel à notre service de réparation, ce qui vaut d'autant plus dans une maison que personne n'occupe en semaine.

L'entretien d'une maison qu'on ne visite pas toutes les semaines

Les filtres se rincent aux deux semaines dans une maison habitée en continu ; ici, le rythme suit l'occupation, et un rinçage par séjour suffit. L'unité extérieure doit rester dégagée de la neige et des feuilles, ce qui compte hors des secteurs déneigés. L'entretien CVAC annuel reprend les serpentins, le condensat et les raccords. La fiche demande 220 V, un MCA de 15 A et un disjoncteur de 15 A sur un circuit dédié, et chaque tête a sa propre paire de lignes.

AirGreen, pour une résidence secondaire

Entreprise familiale depuis plus de quinze ans, nous couvrons Montréal, Laval, Longueuil, la Rive-Nord et la Rive-Sud, avec les licences RBQ en ventilation, en réfrigération et en électricité et une assurance responsabilité de 5 000 000 $. L'évaluation est gratuite et la soumission est remise par écrit. Nos réalisations comprennent des maisons occupées par intermittence, où l'accès se planifie avec le propriétaire.

Demandez votre estimation gratuite pour la Thermopompe 3-Zones DURASTAR Standard | 60 000 BTU - R454B. Nous plaçons l'unité extérieure loin des chambres, réglons le soufflage de nuit des trois têtes et fixons un calendrier d'entretien adapté à une occupation de fin de semaine.

Garantie : 10 ans sur le compresseur, 10 ans sur les pièces et 6 ans sur la main-d’œuvre, directement du distributeur.

18 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 41,500 BTU/h at −8 °C, 36,000 at −15 °C.

How many heads can I connect?

Up to 6 on this outdoor unit. This product is configured for 3 heads.

Down to what temperature does it heat?

Down to −25 °C.

Is it noisy?

Indoors, the reference head goes down to 24 dB(A). Outdoors, 55 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
Sources checked on October 1, 2026.NEEP, Cold Climate Air Source Heat Pump List, product 389549 (AHRI 215359212): capacities and COP, modulation, SEER2, EER2, HSPF2.Costs: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.