NOVAIR Hyper Heat Wall-Mounted Air Conditioning Heat Pump (-35°C) | 24,000 BTU

In stock
SKU: LEA24SZ35SK-O
24,000BTU/h · cooling capacity
−35 °Cheats down to
$2,544LogisVert grant
ENERGY STAR® · cold climateOptional Wi-FiRefrigerant R-410A10-year warranty
Talk to a technician · 514 316-2973
Model number (outdoor)LEA24SZ35SK-O
Model number (indoor)2LEA24UUSK-I
AHRI211709685

NOVAIR Hyper Heat 24,000 BTU: COP 2.21 at −15 °C, the best of our Hyper Heat units

Its COP of 2.21 at −15 °C is the best of the four Hyper Heat sizes we carry, and NEEP still lists 25,000 BTU/h at that temperature, 104% of its nominal capacity. It suits a large duplex or triplex apartment, or a cottage you live in all winter, that has to stay warm once the cold sets in for good.

Three temperatures, three NEEP figures

Figures listed on NEEP under AHRI certificate 211709685 (record dated November 20, 2026):

  • 8 °C (47 °F): 29,000 BTU/h, 121% of nominal, COP 3.40. NEEP lists a maximum of 30,995 BTU/h.
  • −8 °C (17 °F): 21,200 BTU/h, 88%, COP 2.88.
  • −15 °C (5 °F): 25,000 BTU/h, 104%, COP 2.21.

So the published capacity at −8 °C is lower than at −15 °C. That is not a typo on our end: it is how the NEEP record lists it, and that −8 °C figure is the one LogisVert uses.

COP is the heat you get for the electricity you use. At 2.21, every kilowatt-hour drawn from your electrical panel gives 2.21 kWh of heat, even at −15 °C. Our other three Hyper Heat sizes are listed between 1.80 and 2.00 at that temperature.

NEEP has no figure for anything colder than −15 °C. The Hyper Heat series heats down to −35 °C according to the NOVAIR brochure; take that number for what it is, the point where the unit still runs, not a measured output.

LogisVert: the math starts at −8 °C

Hydro-Québec’s LogisVert program multiplies the capacity at −8 °C by a set rate per 1,000 BTU/h. Because this model is ENERGY STAR certified for cold climates, it gets the $120 rate. Indicative LogisVert amount: $2,544 (21,200 BTU/h × $120 / 1,000). Only Hydro-Québec confirms the assistance granted.

The numbers to put on your application are the AHRI certificate mentioned above and ENERGY STAR ID 2449918. How the program works is explained on our grants page.

Before installation: weight, line set and circuit

According to the NOVAIR Hyper Heat brochure (PDF), the outdoor unit weighs 134.48 lb net, more than four times the head (29.98 lb). It is the heaviest outdoor unit in our NOVAIR wall lineup. All that weight sits on the wall bracket or the ground base.

The outdoor unit measures 37.24 × 16.14 × 31.89 in, and the head 46.85 × 11.2 × 14.59 in. Between them run a 3/8 in and 5/8 in line set, limited to 164 ft (50 m) in length and 82 ft (25 m) in height difference, and a 14 AWG × 4 communication wire.

Power is 208/230 V, single-phase, 60 Hz (the brochure prints “280/230V” for this size, an obvious misprint). The brochure also gives two ampacity rows: “Minimum Ampacity”, 25 A, then a second row also labelled “MCA”, 35 A. AirGreen confirms where both units go, the line route and the circuit during the free on-site assessment of heating needs.

Sound: what you should know

According to the NOVAIR brochure, the head runs at 46.5 dB(A) on high, 44 dB(A) on medium and 35 dB(A) on low. No test conditions are printed with these values. On low, 35 dB(A) is more than our other three Hyper Heat heads, which are listed between 23.5 and 25 dB(A).

The outdoor unit is rated at 62 dB(A). The brochure does not say at what distance or under what conditions this figure is measured; what you hear depends on where the unit goes, and we choose the wall with you during the on-site assessment.

For the head, Québec.ca’s noise scale (“Mesure du bruit”) associates 40 dB(A) with a place perceived as peaceful and 50 dB(A) with the onset of disturbance. Low speed stays under the first mark, while medium and high fall between the two: this is a head for a living area rather than a bedroom.

For cooling

In summer, NEEP lists a SEER2 of 21.5 and an EER2 of 13. SEER2 sums up a whole season; EER2 is the efficiency measured at 35 °C outdoors. You choose this model for winter first; for summer, NEEP lists its rated 24,000 BTU/h at 35 °C (95 °F).

Wi-Fi and the 10-year warranty

The NOVAIR brochures say “Wifi Ready”: the unit is ready for Wi-Fi. Your quote spells out what is included for your installation.

According to the NOVAIR brochures, the 10-year warranty requires the unit to be registered; AirGreen takes care of the registration. The compressor, parts and labour breakdown is in the spec table on this page.

Your project with AirGreen

AirGreen comes to you for the on-site assessment, free of charge, and gives you a firm written quote before any work begins. Our refrigeration mechanics do the installation under AirGreen’s RBQ licence 5645-9605-01 (15.8 ventilation, 15.10 refrigeration, 16 electrical) in Montreal, Laval, Longueuil, the South Shore and the North Shore.

Call 514 316-2973 or email sales@airgreen.ca. The NOVAIR page shows the other Hyper Heat sizes and the Ultra Heat series.

Sold and installed by AirGreen