Wall-Mounted Heat Pump ARCOAIRE 16.8 SEER | 24,000 BTU - R454B
A large family area, heated and cooled with capacity that holds from -8 °C to -15 °C
In many suburban houses, on the South Shore as on the North Shore, the ground floor is organized around one large room: a kitchen with an island, an eating area in front of the patio door, an open family room. That is where the family spends its days, and where comfort matters most. The Wall-Mounted Heat Pump ARCOAIRE 16.8 SEER | 24,000 BTU - R454B is a high-capacity size designed for this space, in heating as well as cooling.
Its certified ratings are 17.0 SEER2, 9.0 EER2 and 8.5 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 3556094. Our product sheet shows an indicative LogisVert amount of $2,052. The series name carries the mention 16.8 SEER; to compare, we rely on the certificate's ratings.
The large living space of a suburban house
A nominal capacity of 24,000 BTU/h typically suits a large open kitchen-eating-family area, with a patio door and several windows. These spaces often have an open staircase to the upper floor and a higher-than-average ceiling, which increases the volume to condition. A single well-placed head covers the whole area as long as the space stays open; the upstairs bedrooms keep their own heating.
Sizing for winter, not just for summer
People often choose a heat pump based on cooling: what capacity it takes to cool the room in July. In Quebec, it is heating that demands the most. Depending on the model, a heat pump delivers more or less heat in deep cold than its nominal capacity; you therefore need to look at the certified capacity at winter temperatures to know what share of the heating it will actually carry.
That reasoning is what justifies a size this large for a big open area. The variable-speed compressor avoids the effect of an oversized unit in summer and in the shoulder seasons: when demand is low, it slows down instead of stopping and restarting. The large capacity thus stays available for winter, without sacrificing comfort the rest of the year.
Stable capacity from -8 °C to -15 °C
The certificate lists 17,100 BTU/h at -8 °C (17 °F), about 71% of nominal capacity, with a COP of 2.29, and 17,100 BTU/h at -15 °C (5 °F), also about 71%, with a COP of 2.01. The two points are measured separately; we report each one as published.
What stands out in these figures is stability: the heat pump delivers the same capacity on an ordinary cold day and in real January cold, with a COP that stays above two. For a large, well-insulated open area, that covers a significant share of the heating demand all winter. The ENERGY STAR cold-climate designation confirms that the pairing was evaluated for this climate.
The role of the baseboards
In a large room, the heat pump will not always cover the demand alone on the coldest days. The existing baseboards therefore stay in place, set a few degrees below the heat pump's set point. For most of the year, they stay cold; during cold peaks, they switch on by themselves to top up. If one particular baseboard switches on often, it is a sign that a corner of the room is less well served: the direction of the louvres can then be adjusted.
Summer in the big room
In cooling mode, the nominal capacity is 24,000 BTU/h, enough for an open area where the patio door, the windows and the kitchen add heat late in the day. The 9.0 EER2 rating measures efficiency on a hot day, and the SEER2 rating of 17.0 sums up the full season. At low speed, the indoor coil condenses moisture from the air, which drains away: continuous dehumidification keeps the room comfortable without an icy draft.
Electrical and air distribution
A heat pump of this capacity needs a dedicated circuit of a higher rating than a small unit. We check the capacity of the panel and the electrical service during the visit, taking into account the baseboards, the range, the water heater and the other loads. As for the air, the open staircase works both ways: in winter, some heat rises to the upper floor; in summer, cool air tends to stay on the ground floor. We take this into account when choosing the wall for the head.
The ratings, explained
- SEER2 of 17.0: cooling efficiency over the whole summer.
- EER2 of 9.0: cooling efficiency at the hottest moment.
- HSPF2 of 8.5: heating efficiency over the whole season.
- COP of 2.29 at -8 °C and 2.01 at -15 °C: heat delivered per unit of electricity, where an electric baseboard delivers one.
These figures come from certificate AHRI 215324158, published by NEEP. The circuit uses R-454B refrigerant, from the new generation, with a much lower global warming potential than the previous one; classified A2L, it requires precise installation methods that we apply on every job.
Indicative LogisVert amount: $2,052
Our product sheet shows an indicative LogisVert amount of $2,052 for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.
Installation, step by step
Visit and head location
The visit is free. We measure the open area, the patio door and the windows, note the insulation and ceiling height, then run the on-site assessment. The wall head goes up high, on a wall from which the airflow can cross the room lengthwise, away from the stove and hood, and without aiming directly at the table or the sofa. It is secured to the framing with a drainage slope for condensate.
Outdoor unit, lines and commissioning
The outdoor unit of a heat pump this size is bulkier; it sits on a sturdy ground stand or on a wall stand designed for its load, above the snow line, away from bedroom windows, including the neighbours', and away from the patio where you spend the summer. The refrigerant lines, the cable and the drain go through a single sealed opening, and a line cover can finish the run. At commissioning, the circuit is evacuated and checked for tightness, then we test heating, cooling and the drain, and set the baseboards as backup.
Maintenance
Rinse the indoor filters every two weeks in season; near a kitchen, they also catch fine cooking particles. Keep the outdoor unit clear of snow and leaves, and plan annual HVAC maintenance of the coils, drain and electrical connections. In winter, white vapour during defrost and a short pause in heating are normal. Our cleaning service takes over when you prefer to hand off the annual visit.
AirGreen, for the life of the installation
A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.