Wall-Mounted Heat Pump ARCOAIRE QuietComfort | 12,000 BTU 115V - R454B
A heat pump for the living room, even when the electrical panel is full
In many older houses and in a number of condos, the heat pump project runs into the same obstacle: the electrical panel has no free space left. The Wall-Mounted Heat Pump ARCOAIRE QuietComfort | 12,000 BTU 115V - R454B was chosen for this situation. It runs on a 115 V circuit, a useful option when the electrical panel has no room left for a double breaker.
Its certified ratings are 23.5 SEER2, 13.0 EER2 and 9.5 HSPF2. The system is ENERGY STAR certified under ENERGY STAR ID 3556069, and the certificate still lists its capacity at -25 °C. Our product sheet shows an indicative LogisVert amount of $500.
Why 115 V changes the picture
Most wall-mounted heat pumps need a double breaker at the panel, which takes up two spaces. When the panel is already filled by baseboards, the range, the dryer and the water heater, you sometimes have to add a subpanel or replace the panel before even talking about a heat pump. A 115 V unit connects to a single breaker, which leaves more options for finding room.
115 V does not remove the need for a dedicated circuit: the heat pump must have its own circuit, and the panel's total capacity must allow it. That is what we check during the visit, before proposing anything. For you, day to day, nothing changes: the variable-speed compressor modulates its output the same way, and the wall head heats and cools like any other.
Which rooms it suits
A living room, a large bedroom or a well-insulated small apartment: that is the territory of a nominal capacity of 12,000 BTU/h. Its compressor slows down when the room is at the set point and speeds up when the door opens or the cold sets in, which keeps the temperature steady. In a larger home, the head covers the main room, and closed bedrooms keep their baseboards.
In a condo, 115 V is often appreciated for another reason: the unit's panel is often compact and already well filled. The outdoor unit is then placed on the balcony or an exterior wall, and its location generally has to be approved by the condo board. We take this into account from the first visit.
Winter heating, certified figures
The certificate lists 10,000 BTU/h at -8 °C (17 °F), about 83% of nominal capacity, with a COP of 2.57, and 7,700 BTU/h at -15 °C (5 °F), about 64%, with a COP of 2.33. The two points are measured separately; we report each one as published.
These figures describe a very efficient unit in the most common winter temperatures, with a high COP at -15 °C. They also show that capacity decreases as the cold deepens: at -15 °C, the heat pump delivers less heat than at -8 °C, and the baseboards take on a larger share of the work.
Down to -25 °C
The certificate publishes the maximum capacity at -25 °C (-13 °F): 4,000 BTU/h, about 33% of nominal capacity, with a COP of 1.50. The heat pump therefore still runs at that temperature and delivers more heat than it consumes in electricity, but it can no longer carry the heating of a room on its own. This pairing does not have the ENERGY STAR cold-climate designation; we present it for what it is: an efficient complement to the baseboards, not a complete replacement for them.
Baseboards and heat pump: the right split
The most efficient setting is simple. The heat pump holds the main set point; the baseboard thermostats are set a few degrees lower. Through the fall, the spring and most winter days, the heat pump does the work alone. When the cold becomes more intense, the baseboards switch on by themselves to make up the difference, without any action on your part.
This split gets the best out of both systems: the heat pump's more economical heat covers most of the season, and the baseboards already in place provide security on the coldest nights.
Cooling and dehumidification
In cooling mode, the nominal capacity is 12,000 BTU/h. The 13.0 EER2 rating measures efficiency on a hot day. Running long at low speed keeps the indoor coil cold, and moisture from the air condenses on it before draining away. This continuous dehumidification makes the living room comfortable without setting the temperature too low, and is a clear improvement over a window air conditioner that blocks the view.
The ratings, explained
- SEER2 of 23.5: seasonal cooling efficiency.
- EER2 of 13.0: cooling efficiency at the peak of the heat.
- HSPF2 of 9.5: seasonal heating efficiency, the most decisive in Quebec.
- COP: heat delivered per unit of electricity. A baseboard delivers one; this pairing delivers 2.57 at -8 °C, 2.33 at -15 °C and 1.50 at -25 °C, according to the certificate.
These figures come from certificate AHRI 215324129, published by NEEP. The circuit uses R-454B refrigerant, from the new generation, with a much lower global warming potential than the previous generation.
Indicative LogisVert amount: $500
Our product sheet shows an indicative LogisVert amount of $500 for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.
Installation, step by step
Visit and panel check
For this model, the visit often starts at the electrical panel. We look at the free spaces, the capacity of the electrical service and the existing loads, to confirm that the 115 V circuit can be added. We then run the room's on-site assessment and choose with you the wall for the head, up high, where the airflow covers the room.
If the panel truly allows no addition, we tell you clearly and present the possible options, from rearranging certain circuits to replacing the panel, before preparing the quote. You decide knowing the whole project, not after the fact.
Mounting, lines and outdoor unit
The indoor unit is secured to the framing with a drainage slope for condensate. The outdoor unit goes on a ground or wall stand, above the snow line, away from bedroom windows, including the neighbours'. The refrigerant lines, the cable and the drain go through a single sealed opening, and a line cover can finish the run. At commissioning, the circuit is evacuated and checked for tightness, then we test heating, cooling and the drain, and set the baseboards as backup.
Maintenance and warranty
Rinse the indoor filters every two weeks in season, keep the outdoor unit clear of snow and leaves, and plan annual HVAC maintenance of the coils, drain and electrical connections. In winter, white vapour during defrost and a short pause in heating are normal. Our cleaning service takes over when you prefer to hand off the annual visit.
Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor.
AirGreen, for the life of the installation
A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.
Request your free estimate for the Wall-Mounted Heat Pump ARCOAIRE QuietComfort | 12,000 BTU 115V - R454B. We check your electrical panel, assess the room and confirm your grant eligibility before signing.
