PTAC AMANA PTH R32 J Heat Pump | 7,000 BTU | Greater Montreal
Is it the right size for this room?
Amana doesn't publish a room size for this unit. From its 7,100 BTU/h of cooling, we estimate ≈ 105 to 170 sq ft. Choose your room's area.
It's the right size.
For a 130 to 175 sq ft room, this is the range we estimate for this unit: 7,100 BTU/h of cooling, 6,300 BTU/h of heat-pump heating and a heater of up to 5,000 W when the cold calls for it.
AirGreen estimate: Amana publishes no room size for its PTACs, so this range is a guide based on cooling capacity. Our estimator confirms the exact area on site.
What it does, in numbers
$12.77
Cooling, all summer
Less than a 60 W light bulb
Bulbs left on day and night for a year. Cooling: 5 h a day for 40 days, the assumption used by Hydro-Québec's air-conditioning calculator. Same calculation for every line: wattage × hours × 11.142 ¢/kWh.
≈$101
Heating, all winter
≈ $8 less than baseboard heaters
Typical 138 sq ft room with one exterior wall, in Montréal: 982 kWh of heat per winter (Environment Canada 1991–2020 climate normals). The heat pump is counted only at 8 °C and warmer, where Amana rates its output; below that, the heater, at the price of a baseboard. If it keeps heating in colder weather, the bill goes down.
≈ $114 for the year, before tax. Winter is 89% of it. If your home stays in the first tier of Rate D in summer (7.065 ¢/kWh), cooling drops to $8.10.
Capacities and currents: Amana catalog MC-DPTAC 09-25 (September 2025) and manual IO-933A (December 2022). Power draw: 573 W in cooling (7,100 BTU/h ÷ EER 12.4), 510 W in heat-pump mode, 5,000 W on the 5 kW heater. Hydro-Québec Rate D in effect since April 1, 2026: 11.142 ¢/kWh second tier, before tax.
What you should know about this one
Published, verifiable facts, not brochure claims.
7,100What it really delivers in cooling
The name says 7,000 BTU: that's the unit's size class. Amana publishes 7,100 BTU/h at 230 V, a little more than its size class, and 7,000 at 208 V, the supply in many buildings.
5,000 WThe heater that takes over
At Amana, the two digits after the series letter (the ** in PTH073J**AXXX) set the heater when ordering: 1.5, 2.5, 3.5 or 5.0 kW at 230 V, 1.3 to 4.1 kW at 208 V. At 5.0 kW it takes a 6-30P plug on 30 A; at 3.5 kW, a 6-20P on 20 A. It heats when the heat pump can no longer keep up.
3.6The COP published at 8 °C
Amana publishes a heat-pump COP of 3.6: 6,300 BTU/h of heat at 230 V. Each kWh you pay for gives back 3.6 in heat, against 1 for the heater or a baseboard.
−7 °CWhen the heat pump hands over
Amana switches the unit from heat pump to the heater when the coil drops below 20 °F (−7 °C), or when the heat pump can't keep up on a two-stage thermostat.
1.7Pints of water it removes per hour
The dehumidification Amana publishes in cooling mode: 1.7 pints per hour. It's what keeps a room comfortable in summer without it turning clammy.
7⅝ inHow far it sticks into the room
Amana quotes a 7⅝ in deep front: the unit takes little space out of the room.
4 °CRoom freeze protection
As soon as the unit senses 40 °F (4 °C) or below, it starts the fan and the heater: an empty room won't freeze in winter.
6-30PThe outlet it needs
With the 5.0 kW heater: a NEMA 6-30P plug on a dedicated 30 A circuit. With 3.5 kW: 6-20P on 20 A. With 2.5 kW: 6-15P on 15 A. In a replacement, the outlet already in the wall dictates the heater size.
It fits the standard 42 × 16 in sleeve
Amana sleeves have the industry-standard dimensions: 42 in wide, 16 ¹⁄₁₆ in high, 14 ⅛ in deep. Our estimator checks the sleeve and the grille in place before ordering.
What it needs on site
In a replacement, we check the outlet and the breaker first: they set the heater size you can use. Our estimator confirms the sleeve, the outlet and the slope before ordering.
Complete spec sheetData and cited sources
- Model
- PTH073J**AXXX
- Cooling capacity (208/230 V)
- 7,000 / 7,100 BTU/h
- Heating capacity, heat pump (208/230 V)
- 6,100 / 6,300 BTU/h
- Electric heater (options)
- 1.5 kW · 2.5 kW · 3.5 kW · 5.0 kW
- EER (208/230 V)
- 12.8 / 12.4
- COP (heat pump, 8 °C)
- 3.6
- Current — compressor
- 3.2 A
- Power — cooling (208/230 V)
- 545 / 570 W
- Power — heat pump (230 V)
- 510 W
- Airflow (low/high)
- 245 / 330 cfm
- Dehumidification
- 1.7 pints/h
- Application range
- ≈ 105 to 170 sq ft (AirGreen estimate)
- Front
- 7⅝ in deep
- Sleeve
- 42 × 16 ¹⁄₁₆ in, 14 ⅛ in deep
- Net weight
- 106 lb
- Refrigerant
- R-32
- Heat pump → heater
- coil below 20 °F (−7 °C)
- Power supply
- 208/230 V · 1 ph · 60 Hz
All values: Amana catalog MC-DPTAC 09-25 (September 2025) and manual IO-933A (December 2022). Operating cost: cooling at 573 W for 200 h per summer; heating estimated for a typical 138 sq ft room (982 kWh of heat per winter, heat pump counted at 8 °C and warmer); at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The neighbouring models
Talk to an HVAC technician before you choose
We check the existing sleeve, the outlet and the heater size, and give you an installed price. For a building, we order the same series for every room.
A PTAC Heat Pump Sized for a Small Room
The AMANA PTH R32 J PTAC Heat Pump, 7,000 BTU (PTH073J**AXXX) is the smallest size in the PTH line, Amana’s standard heat pump with auxiliary electric heat. It’s the pick for a small bedroom, an enclosed office or a residence room, the kind of space where a bigger unit would reach the setpoint too fast and spend its time starting and stopping.
On the 208 V supply found in many buildings, it gives up almost nothing and actually gains efficiency: EER goes from 12.4 at 230 V to 12.8 at 208 V and COP from 3.6 to 3.7, while capacity only slips from 7,100 to 7,000 BTU/h. Within the family, the R-410A K version of this size uses more power for the same cooling, and the HEH073J, the high-efficiency version, goes further still on EER and COP.
By the Numbers
- Cooling: 7,100 BTU/h at 230 V, 7,000 at 208 V
- Heat pump: 6,300 BTU/h at 230 V, 6,100 at 208 V
- EER: 12.4 at 230 V, 12.8 at 208 V
- COP: 3.6 at 230 V, 3.7 at 208 V
- Compressor: 570 W in cooling, 510 W in heating (230 V)
- Net weight: 106 lb
Heating on 510 W, Then Handing Over
Rated at 47 °F (8.3 °C), its heat pump delivers 6,300 BTU/h while asking only 510 W of the compressor; for the same heat, an electric heater would use about 3.6 times as much electricity. When the cold sets in, Amana switches it to the electric heater, up to 5 kW depending on the heater chosen when ordering, as soon as its coil drops below 20 °F (−7 °C) or it can no longer keep up. Automatic emergency heat also takes over if the heat pump fails.
What Matters in a Small Room
- Cycles: the compressor stays on for at least 4 minutes each time it starts, which limits short cycles in a small room.
- Sleep: two fan motors, a tangential indoor fan and the cabinet’s STC 29 rating, a measure of sound transmission, matter when the unit sits a few steps from the bed.
- Soft stop: the fan keeps running for 30 seconds after the compressor or heater stops.
- Filters: washable, they pull out easily for cleaning.
- Eden: compatible with the Eden wireless thermostat and the Eden Concierge energy-management system, sold separately with their own fees; according to Amana, Eden can cut energy use by up to 35%.
- Setup: Bluetooth® and RF are built in, and the Amana PTAC Connect app (iOS and Android) is used to set it up and diagnose it.
On the refrigerant side, it runs on R-32, with a GWP of 675 (IPCC Fourth Assessment Report). According to Amana, R-32 delivers up to 12% more efficiency than R-410A and needs up to 40% less refrigerant charge.
Fitting an Existing Sleeve
The chassis slides into the standard 42 × 16 in wall sleeve; if the sleeve in place is compatible, the old unit comes out and this one takes its spot. Our on-site assessment of your heating and cooling needs is also when we check that sleeve, the outdoor grille and the 230/208 V, single-phase, 60 Hz supply. You then receive a detailed quote before the work begins, and the unit is installed by our refrigeration technicians, under AirGreen’s RBQ licence 5645-9605-01. A family business rooted in Montreal for more than 15 years, AirGreen has more than 15 installation crews and serves Montreal, Laval, Longueuil, the North Shore and the South Shore.
Warranty
Amana five-year limited warranty: in year 1 the whole unit is covered (parts and labour); in years 2 to 5 the sealed system is covered (parts, labour and refrigerant) and functional parts are covered for parts only. AirGreen’s installation warranty is set out in your quote.