PTAC AMANA PTH R32 J Heat Pump | 9,000 BTU | Greater Montreal

In stock
SKU: PTH093J**AXXX
9,000 BTU/h actual≈ 125 to 185 sq ftHeat pump + 5 kW max
Talk to an HVAC technician · 514 316-2973
Heat pump and a heater of up to 5 kWStandard 42 × 16 in sleeve6-year compressor warranty
01 · Your room

Is it the right size for this room?

Amana doesn't publish a room size for this unit. From its 9,000 BTU/h of cooling, we estimate ≈ 125 to 185 sq ft. Choose your room's area.

It's the right size.

For a 130 to 175 sq ft room, this is the range we estimate for this unit: 9,000 BTU/h of cooling, 8,200 BTU/h of heat-pump heating and a heater of up to 5,000 W when the cold calls for it.

AirGreen estimate: Amana publishes no room size for its PTACs, so this range is a guide based on cooling capacity. Our estimator confirms the exact area on site.

02 · Performance

What it does, in numbers

9,000BTU/h
Cooling at 230 V9,000 at 208 V, the supply in many buildings.
8,200BTU/h
Heat-pump heatingRated at 8 °C (47 °F).
5,000W
Maximum electric heater4,100 W at 208 V. It heats when the heat pump can no longer keep up.
12.4EER
Cooling efficiencyThat's 726 W drawn at 230 V for 9,000 BTU/h.
What it costs per yearTypical 155 sq ft room · Rate D
Summer · cooling

$16.18

Cooling, all summer

Less than a 60 W light bulb

Bulbs left on day and night for a year. Cooling: 5 h a day for 40 days, the assumption used by Hydro-Québec's air-conditioning calculator. Same calculation for every line: wattage × hours × 11.142 ¢/kWh.

Winter · heating

≈$114

Heating, all winter

≈ $9 less than baseboard heaters

Heat pump8 °C and warmer outside · 10% of the heat≈ $4
Electric heaterBelow 8 °C · 90% of the heat≈ $111

Typical 155 sq ft room with one exterior wall, in Montréal: 1,107 kWh of heat per winter (Environment Canada 1991–2020 climate normals). The heat pump is counted only at 8 °C and warmer, where Amana rates its output; below that, the heater, at the price of a baseboard. If it keeps heating in colder weather, the bill goes down.

≈ $130 for the year, before tax. Winter is 88% of it. If your home stays in the first tier of Rate D in summer (7.065 ¢/kWh), cooling drops to $10.26.

$0.08/h
One hour of cooling
$0.07/h
One hour of heat-pump heating
$0.56/h
One hour on the 5 kW heater

Capacities and currents: Amana catalog MC-DPTAC 09-25 (September 2025) and manual IO-933A (December 2022). Power draw: 726 W in cooling (9,000 BTU/h ÷ EER 12.4), 665 W in heat-pump mode, 5,000 W on the 5 kW heater. Hydro-Québec Rate D in effect since April 1, 2026: 11.142 ¢/kWh second tier, before tax.

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

9,000What it really delivers in cooling

The name says 9,000 BTU: that's the unit's size class. Amana publishes 9,000 BTU/h at 230 V and at 208 V, the supply in many buildings: the capacity doesn't drop.

5,000 WThe heater that takes over

At Amana, the two digits after the series letter (the ** in PTH093J**AXXX) set the heater when ordering: 1.5, 2.5, 3.5 or 5.0 kW at 230 V, 1.3 to 4.1 kW at 208 V. At 5.0 kW it takes a 6-30P plug on 30 A; at 3.5 kW, a 6-20P on 20 A. It heats when the heat pump can no longer keep up.

3.6The COP published at 8 °C

Amana publishes a heat-pump COP of 3.6: 8,200 BTU/h of heat at 230 V. Each kWh you pay for gives back 3.6 in heat, against 1 for the heater or a baseboard.

−7 °CWhen the heat pump hands over

Amana switches the unit from heat pump to the heater when the coil drops below 20 °F (−7 °C), or when the heat pump can't keep up on a two-stage thermostat.

2Pints of water it removes per hour

The dehumidification Amana publishes in cooling mode: 2 pints per hour. It's what keeps a room comfortable in summer without it turning clammy.

7⅝ inHow far it sticks into the room

Amana quotes a 7⅝ in deep front: the unit takes little space out of the room.

4 °CRoom freeze protection

As soon as the unit senses 40 °F (4 °C) or below, it starts the fan and the heater: an empty room won't freeze in winter.

6-30PThe outlet it needs

With the 5.0 kW heater: a NEMA 6-30P plug on a dedicated 30 A circuit. With 3.5 kW: 6-20P on 20 A. With 2.5 kW: 6-15P on 15 A. In a replacement, the outlet already in the wall dictates the heater size.

Replacement

It fits the standard 42 × 16 in sleeve

Amana sleeves have the industry-standard dimensions: 42 in wide, 16 ¹⁄₁₆ in high, 14 ⅛ in deep. Our estimator checks the sleeve and the grille in place before ordering.

42 × 16
inches, standard size
04 · Installation

What it needs on site

42 × 16 in sleeveIndustry-standard size
7⅝ in frontStandard 14 ⅛ in sleeve
Dedicated 30 A circuitFor the 5.0 kW heater (NEMA 6-30P plug)
Condensate thrown on the coilSlinger ring: the water evaporates outside
102 lbUnit weight

In a replacement, we check the outlet and the breaker first: they set the heater size you can use. Our estimator confirms the sleeve, the outlet and the slope before ordering.

Complete spec sheetData and cited sources
Model
PTH093J**AXXX
Cooling capacity (208/230 V)
9,000 / 9,000 BTU/h
Heating capacity, heat pump (208/230 V)
8,000 / 8,200 BTU/h
Electric heater (options)
1.5 kW · 2.5 kW · 3.5 kW · 5.0 kW
EER (208/230 V)
12.5 / 12.4
COP (heat pump, 8 °C)
3.6
Current — compressor
4 A
Power — cooling (208/230 V)
720 / 725 W
Power — heat pump (230 V)
665 W
Airflow (low/high)
264 / 290 cfm
Dehumidification
2 pints/h
Application range
≈ 125 to 185 sq ft (AirGreen estimate)
Front
7⅝ in deep
Sleeve
42 × 16 ¹⁄₁₆ in, 14 ⅛ in deep
Net weight
102 lb
Refrigerant
R-32
Heat pump → heater
coil below 20 °F (−7 °C)
Power supply
208/230 V · 1 ph · 60 Hz

All values: Amana catalog MC-DPTAC 09-25 (September 2025) and manual IO-933A (December 2022). Operating cost: cooling at 726 W for 200 h per summer; heating estimated for a typical 155 sq ft room (1,107 kWh of heat per winter, heat pump counted at 8 °C and warmer); at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The neighbouring models

Talk to an HVAC technician before you choose

We check the existing sleeve, the outlet and the heater size, and give you an installed price. For a building, we order the same series for every room.

9,000 BTU/h Whether the Building Runs on 230 or 208 V

The AMANA PTH R32 J PTAC Heat Pump, 9,000 BTU (PTH093J**AXXX) is the size meant for a standard bedroom or an enclosed office in the PTH line, Amana’s standard heat pump with auxiliary electric heat. Unlike a PTC air conditioner, which heats with its electric heater only, it heats with its heat pump first.

What sets it apart is how it holds up on 208 V: Amana publishes 9,000 BTU/h of cooling on both voltages, and EER even climbs from 12.4 to 12.5. Within the family, the HEH093J offers exactly the same capacity, in cooling and in heating; what it adds is a higher EER and COP. The R-410A K version keeps the capacity but uses more power.

By the Numbers

  • Cooling: 9,000 BTU/h at 230 V and at 208 V
  • Heat pump: 8,200 BTU/h at 230 V, 8,000 at 208 V
  • EER: 12.4 at 230 V, 12.5 at 208 V
  • COP: 3.6 at 230 V and at 208 V
  • Compressor: 725 W in cooling, 665 W in heating (230 V)
  • Net weight: 102 lb

From Heat-Pump Heating to the Electric Backup

At 47 °F (8.3 °C), the point where Amana rates its performance, the heat pump delivers 8,200 BTU/h with a COP of 3.6: every kilowatt-hour it uses comes back as 3.6 in heat. When its coil drops below 20 °F (−7 °C), or if it can no longer keep up, the unit switches to its electric heater, up to 5 kW depending on the heater chosen when ordering; it also does so automatically if the heat pump fails.

The Details of a Well-Kept Room

  • Humidity: in cooling it removes 2 pints of water per hour, which the slinger ring throws onto the outdoor coil.
  • Low profile: a Quiet White front 7⅝ in deep, set flush with the floor thanks to zero floor clearance.
  • Settings out of the way: the ventilation control is hidden, and the Amana PTAC Connect app (iOS and Android), over Bluetooth®, handles setup and diagnostics.
  • Constant fan: one mode keeps the fan running at all times to keep the room’s air moving.
  • Eden: compatible with the Eden wireless thermostat and the Eden Concierge energy-management system, sold separately with their own fees; according to Amana, Eden can cut energy use by up to 35%.

The R-32 it uses has a GWP of 675 (IPCC Fourth Assessment Report). According to Amana, R-32 delivers up to 12% more efficiency than R-410A and needs up to 40% less refrigerant charge.

Installation by AirGreen

For a standard bedroom, it goes into the standard 42 × 16 in wall sleeve; in a replacement, it takes the old unit’s place if the sleeve is compatible. We start with an on-site assessment of your heating and cooling needs, checking the sleeve, the outdoor grille and the 230/208 V, single-phase, 60 Hz circuit. You receive a detailed quote before the work begins, then the installation goes to our refrigeration technicians, under AirGreen’s RBQ licence 5645-9605-01. A family business rooted in Montreal for more than 15 years, AirGreen has more than 15 installation crews and serves Montreal, Laval, Longueuil, the North Shore and the South Shore.

Warranty

Amana five-year limited warranty: in year 1 the whole unit is covered (parts and labour); in years 2 to 5 the sealed system is covered (parts, labour and refrigerant) and functional parts are covered for parts only. AirGreen’s installation warranty is set out in your quote.

Quote and Contact

Call 514 316-2973 for Montreal and Laval, 514 316-3007 for the South Shore, or email sales@airgreen.ca.