AMANA PTH R410A K PTAC Heat Pump | 7,000 BTU | Montreal
Is it the right size for this room?
Amana doesn't publish a room size for this unit. From its 7,100 BTU/h of cooling, we estimate ≈ 105 to 170 sq ft. Choose your room's area.
It's the right size.
For a 130 to 175 sq ft room, this is the range we estimate for this unit: 7,100 BTU/h of cooling, 6,500 BTU/h of heat-pump heating and a heater of up to 5,000 W when the cold calls for it.
AirGreen estimate: Amana publishes no room size, so we apply the application ranges Trane publishes for its PTACs of the same cooling capacity. Our estimator confirms the exact area on site.
What it does, in numbers
$13.19
Cooling, all summer
Less than a 60 W light bulb
Bulbs left on day and night for a year. Cooling: 5 h a day for 40 days, the assumption used by Hydro-Québec's air-conditioning calculator. Same calculation for every line: wattage × hours × 11.142 ¢/kWh.
≈$101
Heating, all winter
≈ $8 less than baseboard heaters
Typical 138 sq ft room with one exterior wall, in Montréal: 982 kWh of heat per winter (Environment Canada 1991–2020 climate normals). The heat pump is counted only at 8 °C and warmer, where Amana rates its output; below that, the heater, at the price of a baseboard. If it keeps heating in colder weather, the bill goes down.
≈ $115 for the year, before tax. Winter is 88% of it. If your home stays in the first tier of Rate D in summer (7.065 ¢/kWh), cooling drops to $8.36.
Capacities and currents: Amana catalog MC-DPTAC 10-23 (October 2023) and manual IO-933A (December 2022). Power draw: 592 W in cooling (7,100 BTU/h ÷ EER 12.0), 560 W in heat-pump mode, 5,000 W on the 5 kW heater. Hydro-Québec Rate D in effect since April 1, 2026: 11.142 ¢/kWh second tier, before tax.
What you should know about this one
Published, verifiable facts, not brochure claims.
7,100What it really delivers in cooling
The name says 7,000 BTU: that's the unit's size class. Amana publishes 7,100 BTU/h at 230 V, a little more than its size class, and 7,000 at 208 V, the supply in many buildings.
5,000 WThe heater that takes over
At Amana, the two digits after the series letter (the ** in PTH073K**AXXX) set the heater when ordering: 1.5, 2.5, 3.5 or 5.0 kW at 230 V, 1.3 to 4.1 kW at 208 V. At 5.0 kW it takes a 6-30P plug on 30 A; at 3.5 kW, a 6-20P on 20 A. It heats when the heat pump can no longer keep up.
3.4The COP published at 8 °C
Amana publishes a heat-pump COP of 3.4: 6,500 BTU/h of heat at 230 V. Each kWh you pay for gives back 3.4 in heat, against 1 for the heater or a baseboard.
−7 °CWhen the heat pump hands over
Amana switches the unit from heat pump to the heater when the coil drops below 20 °F (−7 °C), or when the heat pump can't keep up on a two-stage thermostat.
1.7Pints of water it removes per hour
The dehumidification Amana publishes in cooling mode: 1.7 pints per hour. It's what keeps a room comfortable in summer without it turning clammy.
7⅝ inHow far it sticks into the room
Amana quotes a 7⅝ in deep front, one of the slimmest in the industry: the unit takes less space out of the room.
4 °CRoom freeze protection
As soon as the unit senses 40 °F (4 °C) or below, it starts the fan and the heater: an empty room won't freeze in winter.
6-30PThe outlet it needs
With the 5.0 kW heater: a NEMA 6-30P plug on a dedicated 30 A circuit. With 3.5 kW: 6-20P on 20 A. With 2.5 kW: 6-15P on 15 A. In a replacement, the outlet already in the wall dictates the heater size.
It fits the standard 42 × 16 in sleeve
Amana sleeves have the industry-standard dimensions: 42 in wide, 16 ¹⁄₁₆ in high, 14 ⅛ in deep. Our estimator checks the sleeve and the grille in place before ordering.
What it needs on site
In a replacement, we check the outlet and the breaker first: they set the heater size you can use. Our estimator confirms the sleeve, the outlet and the slope before ordering.
Complete spec sheetData and cited sources
- Model
- PTH073K**AXXX
- Cooling capacity (208/230 V)
- 7,000 / 7,100 BTU/h
- Heating capacity, heat pump (208/230 V)
- 6,400 / 6,500 BTU/h
- Electric heater (options)
- 1.5 kW · 2.5 kW · 3.5 kW · 5.0 kW
- EER (208/230 V)
- 12.4 / 12.0
- COP (heat pump, 8 °C)
- 3.4
- Current — compressor
- 3.3 A
- Power — cooling (208/230 V)
- 560 / 590 W
- Power — heat pump (230 V)
- 560 W
- Airflow (low/high)
- 245 / 330 cfm
- Dehumidification
- 1.7 pints/h
- Application range
- ≈ 105 to 170 sq ft (AirGreen estimate)
- Front
- 7⅝ in deep
- Sleeve
- 42 × 16 ¹⁄₁₆ in, 14 ⅛ in deep
- Net weight
- 106 lb
- Refrigerant
- R-410A
- Heat pump → heater
- coil below 20 °F (−7 °C)
- Power supply
- 208/230 V · 1 ph · 60 Hz
All values: Amana catalog MC-DPTAC 10-23 (October 2023) and manual IO-933A (December 2022). Operating cost: cooling at 592 W for 200 h per summer; heating estimated for a typical 138 sq ft room (982 kWh of heat per winter, heat pump counted at 8 °C and warmer); at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The neighbouring models
Talk to an HVAC technician before you choose
We check the existing sleeve, the outlet and the heater size, and give you an installed price. For a building, we order the same series for every room.
The ideal solution for hotel chains seeking performance, centralized control and energy efficiency
In the hotel industry, managing room thermal comfort is a strategic issue. Guests expect a stable, quiet, and pleasant indoor climate, while managers are looking for reliable, easy-to-control, and cost-effective systems. At AirGreen , we offer a solution perfectly suited to these needs: the AMANA PTH R410A K | 7,000 BTU PTAC Heat Pump , a unit designed to offer a complete and sustainable solution to large hotels in Montreal, Laval, Longueuil, as well as on the North and South Shores.
A device designed for hotel requirements
The AMANA PTH R410A K PTAC heat pump is more than just an HVAC unit. Its design, technology, and features are directly targeted at the needs of multi-room properties. Whether equipping a new hotel or replacing an existing one, it meets key requirements:
-
Exceptional energy performance : with an EER of up to 14.0 and a COP of up to 3.9, it significantly reduces electricity consumption and may qualify for subsidies offered by electricity suppliers.
-
Proven Reliability : Assembled in the USA for over 45 years, every unit is 100% factory tested, with rigorous leak and performance checks before shipping.
-
Optimal guest comfort : extremely quiet operation thanks to an internal tangential fan and acoustic design offering an STC of 29, ensuring peaceful nights.
Integrated technologies for simplified management at scale
For hotels, managing HVAC systems room by room can be a headache. The AMANA PTH R410A K incorporates advanced technologies for centralized and intelligent control:
Integrated Bluetooth® connectivity
The Amana mobile app (iOS and Android) allows technical teams to quickly configure, diagnose and adjust unit settings, reducing response and commissioning time.
Integrated RF communication
Each unit can connect wirelessly to the Eden DS01G thermostat or the Eden Concierge energy management system, capable of reducing PTAC energy consumption by up to 35% or more . Ideal for hotel chains, this system allows:
-
Remote control of all rooms from a central station.
-
Automatic temperature management based on occupancy.
-
Optimizing energy costs without compromising customer comfort.
Designed for maintenance and longevity
Hotels can't afford frequent service interruptions. The AMANA PTH R410A K is designed to limit maintenance and extend the unit's lifespan:
-
Washable filters are easy to remove for quick maintenance.
-
Integrated filter dryer protects the compressor and prevents acid formation.
-
Condensate dispersion system reducing water discharge and increasing cooling efficiency.
-
Frost protection that automatically activates the heating when the temperature drops to 4°C or below.
Key technical features
-
Cooling capacity : 7,000 BTU
-
Refrigerant gas : R-454B
-
Dimensions : 42 x 21.5 x 16 in
-
Voltage : 220V
-
Manufacturer's warranty : 6 years compressor, 6 years parts, 6 years labor
-
Smart functions : constant fan mode, compressor lock to prevent short cycles, automatic emergency heating.
Specific advantages for hotel chains
-
Quick and standardized installation : the compact design (7⅝" front depth) allows for seamless integration into existing rooms.
-
Centralized multi-room management : ability to control all units from a single supervisory station, reducing labor costs.
-
Premium customer experience : silence, constant thermal comfort, elegant “Quiet White” design that blends perfectly with high-end decors.
-
Reduced operational costs : energy optimization, increased sustainability and simplified maintenance.
Concrete example: modernization of a large hotel in Montreal
Recently, AirGreen assisted a 150-room hotel in downtown Montreal in the transition to the AMANA PTH R410A K PTAC heat pump . The goal: to improve guest comfort, reduce energy consumption and simplify equipment management.
By installing the units in each room and connecting them to the Eden Concierge system, the hotel found:
-
A 32% reduction in your annual energy bill.
-
A significant reduction in maintenance calls thanks to the reliability of the system.
-
Very positive customer feedback on silence and thermal comfort.
Why choose AirGreen for your PTAC installation?
-
Specialized expertise : we have complete mastery of the installation of PTAC in complex hotel environments.
-
Turnkey service : from free estimate to commissioning, including centralized configuration, we manage the entire project.
-
Certified refrigeration technicians : experience and speed of intervention guaranteed.
-
Transparent pricing : no surprises at the end of the project, clear and definitive quote before any start.
Conclusion: a strategic investment for your hotel
The AMANA PTH R410A K | 7,000 BTU PTAC Heat Pump isn't just a high-performance HVAC unit—it's a strategic tool for improving hotel efficiency, guest satisfaction, and profitability. By choosing AirGreen, you'll benefit not only from a premium product, but also from the support of a team that understands the specific needs of major hotel chains.
Contact us today to discuss your project and find out how we can simplify the management of thermal comfort in all your rooms, while reducing your energy costs.
Warranty: 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.