AMANA PTH R410A K PTAC Heat Pump | 9,000 BTU | Montreal

In stock
SKU: PTH093K**AXXX
9,000 BTU/h actual≈ 125 to 185 sq ftHeat pump + 5 kW max
Talk to an HVAC technician · 514 316-2973
Heat pump and a heater of up to 5 kWStandard 42 × 16 in sleeve6-year compressor warranty
01 · Your room

Is it the right size for this room?

Amana doesn't publish a room size for this unit. From its 9,000 BTU/h of cooling, we estimate ≈ 125 to 185 sq ft. Choose your room's area.

It's the right size.

For a 130 to 175 sq ft room, this is the range we estimate for this unit: 9,000 BTU/h of cooling, 8,200 BTU/h of heat-pump heating and a heater of up to 5,000 W when the cold calls for it.

AirGreen estimate: Amana publishes no room size, so we apply the application ranges Trane publishes for its PTACs of the same cooling capacity. Our estimator confirms the exact area on site.

02 · Performance

What it does, in numbers

9,000BTU/h
Cooling at 230 V9,000 at 208 V, the supply in many buildings.
8,200BTU/h
Heat-pump heatingRated at 8 °C (47 °F).
5,000W
Maximum electric heater4,100 W at 208 V. It heats when the heat pump can no longer keep up.
11.9EER
Cooling efficiencyThat's 756 W drawn at 230 V for 9,000 BTU/h.
What it costs per yearTypical 155 sq ft room · Rate D
Summer · cooling

$16.85

Cooling, all summer

Less than a 60 W light bulb

Bulbs left on day and night for a year. Cooling: 5 h a day for 40 days, the assumption used by Hydro-Québec's air-conditioning calculator. Same calculation for every line: wattage × hours × 11.142 ¢/kWh.

Winter · heating

≈$114

Heating, all winter

≈ $9 less than baseboard heaters

Heat pump8 °C and warmer outside · 10% of the heat≈ $4
Electric heaterBelow 8 °C · 90% of the heat≈ $111

Typical 155 sq ft room with one exterior wall, in Montréal: 1,107 kWh of heat per winter (Environment Canada 1991–2020 climate normals). The heat pump is counted only at 8 °C and warmer, where Amana rates its output; below that, the heater, at the price of a baseboard. If it keeps heating in colder weather, the bill goes down.

≈ $131 for the year, before tax. Winter is 87% of it. If your home stays in the first tier of Rate D in summer (7.065 ¢/kWh), cooling drops to $10.68.

$0.08/h
One hour of cooling
$0.08/h
One hour of heat-pump heating
$0.56/h
One hour on the 5 kW heater

Capacities and currents: Amana catalog MC-DPTAC 10-23 (October 2023) and manual IO-933A (December 2022). Power draw: 756 W in cooling (9,000 BTU/h ÷ EER 11.9), 705 W in heat-pump mode, 5,000 W on the 5 kW heater. Hydro-Québec Rate D in effect since April 1, 2026: 11.142 ¢/kWh second tier, before tax.

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

9,000What it really delivers in cooling

The name says 9,000 BTU: that's the unit's size class. Amana publishes 9,000 BTU/h at 230 V and at 208 V, the supply in many buildings: the capacity doesn't drop.

5,000 WThe heater that takes over

At Amana, the two digits after the series letter (the ** in PTH093K**AXXX) set the heater when ordering: 1.5, 2.5, 3.5 or 5.0 kW at 230 V, 1.3 to 4.1 kW at 208 V. At 5.0 kW it takes a 6-30P plug on 30 A; at 3.5 kW, a 6-20P on 20 A. It heats when the heat pump can no longer keep up.

3.4The COP published at 8 °C

Amana publishes a heat-pump COP of 3.4: 8,200 BTU/h of heat at 230 V. Each kWh you pay for gives back 3.4 in heat, against 1 for the heater or a baseboard.

−7 °CWhen the heat pump hands over

Amana switches the unit from heat pump to the heater when the coil drops below 20 °F (−7 °C), or when the heat pump can't keep up on a two-stage thermostat.

2Pints of water it removes per hour

The dehumidification Amana publishes in cooling mode: 2 pints per hour. It's what keeps a room comfortable in summer without it turning clammy.

7⅝ inHow far it sticks into the room

Amana quotes a 7⅝ in deep front, one of the slimmest in the industry: the unit takes less space out of the room.

4 °CRoom freeze protection

As soon as the unit senses 40 °F (4 °C) or below, it starts the fan and the heater: an empty room won't freeze in winter.

6-30PThe outlet it needs

With the 5.0 kW heater: a NEMA 6-30P plug on a dedicated 30 A circuit. With 3.5 kW: 6-20P on 20 A. With 2.5 kW: 6-15P on 15 A. In a replacement, the outlet already in the wall dictates the heater size.

Replacement

It fits the standard 42 × 16 in sleeve

Amana sleeves have the industry-standard dimensions: 42 in wide, 16 ¹⁄₁₆ in high, 14 ⅛ in deep. Our estimator checks the sleeve and the grille in place before ordering.

42 × 16
inches, standard size
04 · Installation

What it needs on site

42 × 16 in sleeveIndustry-standard size
7⅝ in frontStandard 14 ⅛ in sleeve
Dedicated 30 A circuitFor the 5.0 kW heater (NEMA 6-30P plug)
Condensate thrown on the coilSlinger ring: the water evaporates outside
102 lbUnit weight

In a replacement, we check the outlet and the breaker first: they set the heater size you can use. Our estimator confirms the sleeve, the outlet and the slope before ordering.

Complete spec sheetData and cited sources
Model
PTH093K**AXXX
Cooling capacity (208/230 V)
9,000 / 9,000 BTU/h
Heating capacity, heat pump (208/230 V)
8,000 / 8,200 BTU/h
Electric heater (options)
1.5 kW · 2.5 kW · 3.5 kW · 5.0 kW
EER (208/230 V)
12.0 / 11.9
COP (heat pump, 8 °C)
3.4
Current — compressor
4.4 A
Power — cooling (208/230 V)
750 / 755 W
Power — heat pump (230 V)
705 W
Airflow (low/high)
264 / 330 cfm
Dehumidification
2 pints/h
Application range
≈ 125 to 185 sq ft (AirGreen estimate)
Front
7⅝ in deep
Sleeve
42 × 16 ¹⁄₁₆ in, 14 ⅛ in deep
Net weight
102 lb
Refrigerant
R-410A
Heat pump → heater
coil below 20 °F (−7 °C)
Power supply
208/230 V · 1 ph · 60 Hz

All values: Amana catalog MC-DPTAC 10-23 (October 2023) and manual IO-933A (December 2022). Operating cost: cooling at 756 W for 200 h per summer; heating estimated for a typical 155 sq ft room (1,107 kWh of heat per winter, heat pump counted at 8 °C and warmer); at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The neighbouring models

Talk to an HVAC technician before you choose

We check the existing sleeve, the outlet and the heater size, and give you an installed price. For a building, we order the same series for every room.

A high-end solution for the hotel industry: efficiency, comfort and centralized control

At AirGreen , we understand that managing thermal comfort in a large hotel isn't just about installing a few air conditioners. Large hotel chains have specific needs: consistent comfort in every room, energy consumption control, centralized equipment control, and simplified maintenance. The PTAC AMANA PTH R410A K | 9,000 BTU heat pump has been designed to meet these requirements with flying colors.

Thanks to a unique combination of advanced technology , intelligent connectivity and optimal energy performance , this model is a reference for large-scale installation projects in the hotel industry in Montreal, Laval, Longueuil, on the North Shore and the South Shore.


Energy performance and savings on a large scale

The AMANA PTH R410A K boasts high energy efficiencies , with an EER of up to 14.0 and a COP of up to 3.9 . In a hotel setting, where dozens or even hundreds of units operate simultaneously, this performance translates into considerable savings on electricity bills.

By working with AirGreen, your facilities can also be optimized to benefit from subsidies offered by Quebec electricity companies . Our teams will assist you with the administrative process to maximize your return on investment.


Ultra-quiet operation for an optimal customer experience

In the hotel industry, comfort isn't just about temperature: silence is just as essential. This Amana model includes:

  • Dual fan motors (indoor/outdoor) for better sound dissipation.

  • Internal tangential fan reduces operating noise.

  • STC index of 29 , guaranteeing peaceful nights.

For a hotel, this means fewer noise complaints and higher customer satisfaction—crucial for maintaining a great online reputation.


Connectivity and centralized control: simplified room management

The AMANA PTH R410A K integrates Bluetooth® connectivity and an RF module allowing:

  • Instant connection to the Amana mobile app (iOS/Android) to quickly configure and diagnose each unit.

  • Compatibility with the Eden wireless thermostat and the Eden Concierge energy management system.

  • Centralized control : ability to control all units from a single workstation, ideal for hotel managers.

This system can reduce PTAC energy consumption by up to 35% , while allowing rapid adjustments according to room occupancy.


A design thought out for modern hospitality

The Quiet White front panel offers a sleek, modern look that blends seamlessly into any bedroom style, from standard to high-end. The reduced 7 1/2-inch front depth maximizes available space, enhancing the visual perception of bedrooms.


Long-term durability and reliability

Designed and assembled in the USA, each unit is 100% factory tested :

  • Leak tests during manufacturing.

  • Complete check before shipping.

  • Built-in filter drier to extend compressor life.

The manufacturer's warranty covers:

  • 6 years compressor and parts .

  • 6 years labor, straight from the distributor .


Advanced features to meet hotel needs

  • Condensate Dispersion System : Reduces external runoff and improves cooling efficiency.

  • Frost protection : automatic heating activation at 4°C or lower.

  • 30s fan off delay : better restitution of conditioned air.

  • Automatic emergency heating mode : instant switch to electric resistance in the event of heat pump failure.

  • Concealed ventilation control : ideal for managing fresh air standards without customer intervention.

  • Smart Vent & Economizer options : intelligent management of outside air based on conditions.


Multi-chamber installation and deployment with AirGreen

Our expertise is not limited to sales:

  • Personalized study of your building to determine the optimal configuration.

  • Coordinated installation : Our teams quickly deploy units across multiple floors or buildings.

  • Configuration and interconnection of all units for centralized control.

  • Training your staff for daily management and simple diagnostics.

With AirGreen, you benefit from a turnkey solution to equip each room with optimal comfort, while maintaining complete control from a central point.


Concrete example: successful installation in a 120-room hotel in Montreal

Recently, AirGreen equipped a 120-room hotel in downtown Montreal with the AMANA PTH R410A K | 9,000 BTU model. Results:

  • 28% reduction in annual energy bill .

  • Zero noise complaints after installation.

  • Centralized management from reception: possibility of turning off or adjusting units in unoccupied rooms.

  • Reduced maintenance thanks to washable filters and connectivity for remote diagnostics.


Why choose AirGreen for your hotel project?

  • HVAC Expertise : Over 20 years of experience installing heat pumps and PTAC systems.

  • Complete service : from technical study to commissioning.

  • Certified team : qualified refrigeration engineers, compliance with RBQ standards.

  • Transparent pricing : clear prices, no surprises.


Conclusion

The PTAC AMANA PTH R410A K | 9,000 BTU heat pump is the perfect ally for large hotel chains looking for performance, quiet sound, intelligent control and energy savings. With AirGreen , you benefit not only from a cutting-edge product, but also from expert installation and tailor-made support.

Contact us today to plan your facility's equipment and provide your customers with the comfort they deserve, while optimizing your operating costs.

Warranty: 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.