EMERSON Line Voltage 1E65-151 Electronic Thermostat | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: 1E65-151

In a bedroom, the 1E65-151 lowers the temperature by day; in the bathroom, another 1E65-151 warms it up before you wake.

3,000 Wat 240 V, maximum
18 programsfactory preset
1 yearmanufacturer warranty
Programmable
Get my installed price 514 316-2973

Quick facts

Model number1E65-151
ProgrammableYes
Wi-FiNo
Touch screenNo
ENERGY STARNo
Warranty1 year

In a house heated by electric baseboards, every room has its own thermostat, and that is where programming becomes useful. In a bedroom, the 1E65-151 (EMERSON's White-Rodgers line) lowers the temperature by day; in the bathroom, another 1E65-151 warms it up before you wake, with no app and no Wi-Fi. It suits households whose week follows a regular routine.

One schedule for weekdays, another for the weekend

  • Two schedules: weekdays from Monday to Friday and the weekend, with 4 periods a day.
  • 18 preset programs: start from the one closest to your routine, then fine-tune it.
  • Early start: heating begins ahead of time to aim for the setpoint at the scheduled hour.
  • Safety mode: minimum and maximum setpoint limits, handy in a teenager's room or a rented unit.
  • Setpoint from 3 to 30 °C (37 to 86 °F): adjusted in 0.5 °C steps, off below 3 °C.
  • LCD screen: temperature, power bars, time and day.

Loads and circuits

This thermostat runs resistive loads from 1.25 to 12.5 A for heating only: electric baseboards and convectors at 120, 208 or 240 V. Hookup is 2- or 4-wire, with no polarity. It is not suited to a central system or to electric floor heating, and the instructions do not name fan-forced heaters either.

Its neighbours in the line

The sheet for the EMERSON BP150 shows the same programming and load, and also lists a display lit at night (nightlight mode), useful in a child's room. The EMERSON Line Voltage 1E65-144 is not programmable, but it handles up to 4,000 W at 240 V; its sheet also lists optional proportional control.

Installation and programming by AirGreen

Before any wire is touched, we shut the breaker off at the panel, then compare the total wattage of the room's baseboards with the thermostat's range for your circuit voltage: 150 to 1,500 W at 120 V, 260 to 2,600 W at 208 V or 300 to 3,000 W at 240 V. Once the 1E65-151 is in place, we pick the starting program with you. The in-home estimate before the job is free.

Manufacturer document: installation instructions 0037-7457 (BP150, BP125C, 1E65-151). Sold and installed by AirGreen. We serve Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · Key facts

Key facts: EMERSON Line Voltage 1E65-151

Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.

TypeLine-voltage thermostatEMERSON Line Voltage 1E65-151
Forheating only, resistive loads from 1.25 to 12.5 AUse
Power120/208/240 VAC, 50/60 HzPower supply
ConnectionnoneConnectivity
02 · Compatible?

Is the EMERSON Line Voltage 1E65-151 compatible with your heating?

Two steps, thirty seconds. The verdict takes your system and your wiring into account.

Full compatibility table

Heating systemVerdictWhy
Central heat pumpNoA central system is controlled in 24 V: see 24 V thermostats.
Dual energy (heat pump + furnace)NoDual energy is controlled in 24 V: see 24 V thermostats.
Electric furnaceNoA furnace is controlled in 24 V: see 24 V thermostats.
Gas or oil furnaceNoA furnace is controlled in 24 V: see 24 V thermostats.
Steam, gravity or hot waterNoA hydronic system needs a 24 V thermostat or a hydronic control.
Baseboards, convectors, radiant ceilingYesBaseboards, convectors and radiant ceilings, within the thermostat’s load range.
Fan-forced heaterNoThe instructions cover resistive loads only; they do not name fan-forced heaters.
Electric floor heatingNoFloor heating needs a floor thermostat with a probe.
Wall or ducted mini-split heat pumpNoA wall heat pump is controlled by its own brand’s controller.
03 · Wiring

A thermostat that works on 120/240 V

Tap an element to see what it does. A working diagram, not a substitute for the manufacturer’s installation guide.

04 · Try it

Try the EMERSON Line Voltage 1E65-151 before you buy

Raise the setpoint, change the mode: see how it responds.

05 · Your savings

How much good programming can save you

Set up your typical week. The math follows the rule published by Natural Resources Canada.

06 · Winter and rebates

Winter, Rate Flex D and rebates: what this thermostat changes

With Hydro-Québec’s Rate Flex D, electricity costs less most of the winter and more during a few peak hours. A programmable thermostat does the work for you.

07 · Room by room

What each room costs

An interactive drawing of what this kind of control does day to day.

08 · Head to head

The EMERSON Line Voltage 1E65-151 or its closest sibling?

The most useful comparison: the model right next to it in our catalogue.

09 · The right choice

The right thermostat in three questions

If this model is not the right one for you, the page says so and shows you which one is.

10 · Installation

Installed and set up by our technicians, in five steps

What we do at your place, in order. The on-site estimate is free.

  1. 01LoadWe add up the heaters on the circuit and check the thermostat’s range.
  2. 02Shut-offBreaker shut off at the panel, 2- or 4-wire circuit identified.
  3. 03MountingWiring, mounting, power back on.
  4. 04TestHeating checked room by room.
  5. 05SettingsSchedule, connection and app if the model has them.
11 · Specifications

EMERSON Line Voltage 1E65-151 specifications

From the manufacturer’s sheet. Type a word: the list filters as you write.

GeneralTypeprogrammable electronic line-voltage thermostat
GeneralUseheating only, resistive loads from 1.25 to 12.5 A (electric baseboards, convectors); not for a central system
ElectricalPower supply120/208/240 VAC, 50/60 Hz
ElectricalLoad150 to 1,500 W at 120 V, 260 to 2,600 W at 208 V, 300 to 3,000 W at 240 V
ElectricalTerminals2- or 4-wire hookup, no polarity
GeneralProgrammingautomatic mode: one weekday schedule (Monday to Friday) and one weekend schedule, 4 periods per day; 18 preset programs
GeneralSetpoint range3 to 30 °C (37 to 86 °F), in 0.5 °C steps; off below 3 °C
Format and contentsDisplayLCD: temperature, power bars, time and day
GeneralFeaturesearly start, safety mode with minimum and maximum limits
ConnectivityConnectivitynone (no Wi-Fi)
Format and contentsColourwhite
GeneralManufacturer instructions0037-7457 (White-Rodgers)
12 · Questions

Frequently asked questions about the EMERSON Line Voltage 1E65-151

Short answers, no detours.

What does the EMERSON Line Voltage 1E65-151 work with?

According to the manufacturer’s sheet: heating only, resistive loads from 1.25 to 12.5 A (electric baseboards, convectors); not for a central system.

What load can it control?

Up to 3,000 W at 240 V (1,500 W at 120 V), per the manufacturer’s sheet.

Who installs it?

Our technicians: the circuit is shut off at the panel, the heater load is checked, then the thermostat is wired and tested.

Can it be controlled remotely?

Not directly: it has no built-in Wi-Fi.

Does AirGreen install it?

Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your thermostat, installed and set up by our technicians

We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, before any purchase
Quote in 24 hinstalled price, no surprises
Bouchervilleshowroom

Sources checked on October 5, 2026.

  • Manufacturer’s spec sheet for this product (summarized in the description and specifications above)
  • Natural Resources Canada, “Keeping the Heat In”, section 9 (modified September 29, 2025)
  • Hydro-Québec, electricity rates in effect April 1, 2026; Rate Flex D and Winter Credit Option pages (consulted October 5, 2026)
  • Énergir, smart thermostat grant (consulted October 5, 2026)

Savings shown are estimates; only Hydro-Québec and Énergir confirm a rate or a rebate.