EMERSON Line Voltage 1E65-151 Electronic Thermostat | Montreal, Laval, Longueuil, South Shore & North Shore
In a bedroom, the 1E65-151 lowers the temperature by day; in the bathroom, another 1E65-151 warms it up before you wake.
Quick facts
In a house heated by electric baseboards, every room has its own thermostat, and that is where programming becomes useful. In a bedroom, the 1E65-151 (EMERSON's White-Rodgers line) lowers the temperature by day; in the bathroom, another 1E65-151 warms it up before you wake, with no app and no Wi-Fi. It suits households whose week follows a regular routine.
One schedule for weekdays, another for the weekend
- Two schedules: weekdays from Monday to Friday and the weekend, with 4 periods a day.
- 18 preset programs: start from the one closest to your routine, then fine-tune it.
- Early start: heating begins ahead of time to aim for the setpoint at the scheduled hour.
- Safety mode: minimum and maximum setpoint limits, handy in a teenager's room or a rented unit.
- Setpoint from 3 to 30 °C (37 to 86 °F): adjusted in 0.5 °C steps, off below 3 °C.
- LCD screen: temperature, power bars, time and day.
Loads and circuits
This thermostat runs resistive loads from 1.25 to 12.5 A for heating only: electric baseboards and convectors at 120, 208 or 240 V. Hookup is 2- or 4-wire, with no polarity. It is not suited to a central system or to electric floor heating, and the instructions do not name fan-forced heaters either.
Its neighbours in the line
The sheet for the EMERSON BP150 shows the same programming and load, and also lists a display lit at night (nightlight mode), useful in a child's room. The EMERSON Line Voltage 1E65-144 is not programmable, but it handles up to 4,000 W at 240 V; its sheet also lists optional proportional control.
Installation and programming by AirGreen
Before any wire is touched, we shut the breaker off at the panel, then compare the total wattage of the room's baseboards with the thermostat's range for your circuit voltage: 150 to 1,500 W at 120 V, 260 to 2,600 W at 208 V or 300 to 3,000 W at 240 V. Once the 1E65-151 is in place, we pick the starting program with you. The in-home estimate before the job is free.
Manufacturer document: installation instructions 0037-7457 (BP150, BP125C, 1E65-151). Sold and installed by AirGreen. We serve Montréal, Laval, Longueuil, the North Shore and the South Shore.
Key facts: EMERSON Line Voltage 1E65-151
Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.
Is the EMERSON Line Voltage 1E65-151 compatible with your heating?
Two steps, thirty seconds. The verdict takes your system and your wiring into account.
Full compatibility table
A thermostat that works on 120/240 V
Tap an element to see what it does. A working diagram, not a substitute for the manufacturer’s installation guide.
Try the EMERSON Line Voltage 1E65-151 before you buy
Raise the setpoint, change the mode: see how it responds.
How much good programming can save you
Set up your typical week. The math follows the rule published by Natural Resources Canada.
Winter, Rate Flex D and rebates: what this thermostat changes
With Hydro-Québec’s Rate Flex D, electricity costs less most of the winter and more during a few peak hours. A programmable thermostat does the work for you.
What each room costs
An interactive drawing of what this kind of control does day to day.
The EMERSON Line Voltage 1E65-151 or its closest sibling?
The most useful comparison: the model right next to it in our catalogue.
The right thermostat in three questions
If this model is not the right one for you, the page says so and shows you which one is.
Installed and set up by our technicians, in five steps
What we do at your place, in order. The on-site estimate is free.
- 01LoadWe add up the heaters on the circuit and check the thermostat’s range.
- 02Shut-offBreaker shut off at the panel, 2- or 4-wire circuit identified.
- 03MountingWiring, mounting, power back on.
- 04TestHeating checked room by room.
- 05SettingsSchedule, connection and app if the model has them.
EMERSON Line Voltage 1E65-151 specifications
From the manufacturer’s sheet. Type a word: the list filters as you write.
No line matches. Try another word.
Frequently asked questions about the EMERSON Line Voltage 1E65-151
Short answers, no detours.
What does the EMERSON Line Voltage 1E65-151 work with?
According to the manufacturer’s sheet: heating only, resistive loads from 1.25 to 12.5 A (electric baseboards, convectors); not for a central system.
What load can it control?
Up to 3,000 W at 240 V (1,500 W at 120 V), per the manufacturer’s sheet.
Who installs it?
Our technicians: the circuit is shut off at the panel, the heater load is checked, then the thermostat is wired and tested.
Can it be controlled remotely?
Not directly: it has no built-in Wi-Fi.
Does AirGreen install it?
Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.
No question matches. Call us at 514 316-2973.
Your thermostat, installed and set up by our technicians