Quick facts
Most bedrooms, offices and small rooms in an electrically heated home have only one or two baseboards. For these spaces, the Honeywell TH401/U offers fine electronic control in a compact format. It uses silent TRIAC switching and a selectable 15-second cycle for baseboards, which keeps the temperature within ±0.15 °C of the setpoint, according to the manufacturer. The result is gentle, steady heat, without the ups and downs you get with a mechanical thermostat, and without the click of a relay at every cycle. It is a natural choice for bedroom comfort.
Fine precision for average-sized rooms
The TH401 controls electric baseboards, radiant ceilings, convectors and fan-forced heaters on 120 V, 208 V or 240 V circuits. It handles loads from 0.83 A to 10.4 A, which is 200 to 2500 W at 240 V, or 100 to 1250 W at 120 V. This range suits average-sized rooms. For a more heavily loaded circuit, a higher-capacity model such as the TH450/U will be needed; our technicians add up the wattage of the connected units before choosing.
Two cycle types depending on the unit
The operating cycle is selected during installation. The 15-second cycle suits baseboards and units without a fan: power is modulated in short pulses, which stabilizes the room temperature. The 5-minute cycle suits fan-forced heaters, whose fan should not start and stop too often. Setting this parameter correctly is essential to comfort and to the life of the unit.
Useful lockouts
Minimum and maximum setpoint lockouts limit the accessible setting range. A landlord can prevent an excessive setpoint, and a family can keep a child from turning the heat all the way up. The 0.98 sq in. backlit screen displays the temperature and a heating power indicator. Permanent memory keeps the settings without a battery.
Technical specifications
- Stage: 1 heating
- Equipment: electric baseboards, radiant ceilings, convectors, fan-forced heaters
- Voltage: 120 / 208 / 240 VAC, 60 Hz
- Load: 0.83 to 10.4 A (200 to 2500 W at 240 V; 100 to 1250 W at 120 V)
- Silent TRIAC switching
- Selectable cycle: 15 s (baseboards) or 5 min (fan-forced heaters)
- Non-programmable
- Display: 0.98 sq in. backlit, with heating power indicator
- Minimum and maximum setpoint lockout
- Accuracy: ±0.15 °C; setting range: 5 to 30 °C
- Sensor: thermistor
- Permanent memory, no battery; connectivity: none
- Dimensions: 127 x 85 x 30 mm (5.0 x 3.3 x 1.2 in.)
- Colour: white
What our technicians check
Replacing an electric heating thermostat is a chance to check the condition of the circuit. Our technicians look at the condition of the wires in the box, the quality of the old connections, the actual voltage and the total wattage of the connected heating units. These checks confirm that the chosen model suits the load, and then it is wired correctly. Once the control is in place, we run a heating test and check that the room temperature responds as expected. When several rooms have old mechanical thermostats, we can replace them all in a single visit.
Day to day
Using it could not be simpler: you adjust the setpoint with the buttons, and the thermostat takes care of the rest. Thanks to the short cycle and silent switching, the room stays close to the chosen temperature, which often lets you live comfortably at a slightly lower setpoint than with an old mechanical thermostat. At night, the absence of relay noise is a real advantage in a bedroom. The compact 127 x 85 mm format easily replaces an old thermostat, and the backlit screen can be read at a glance.
Saving without programming
A non-programmable thermostat can also help reduce your heating costs, provided you use it with a little discipline. The most effective habit is to lower the setpoint by a few degrees before going to bed or leaving the house for a long period, then raise it again when you return. Precise control helps too: the closer it keeps the temperature to the setpoint, the less you are tempted to turn up the setting to make up for swings. For little-used rooms, a permanently lower setpoint is a simple way to limit consumption in winter.
TH401 or TH450
The TH401/U and the TH450/U share TRIAC switching, ±0.15 °C precision, the choice of a 15-second or 5-minute cycle and the setpoint lockouts. The main difference is capacity: the TH401 handles up to 2500 W at 240 V, while the TH450 goes up to 4000 W at 240 V and adds a keypad lock. For a bedroom or an office with one or two baseboards, the TH401 is more than enough. For a living room or basement with a heavier load, the TH450 is the right choice. If you want programming, the TH105PLUS/U also offers TRIAC switching with a 5-2 schedule.
Usage tips
Once installed, the thermostat goes unnoticed. Set the setpoint that suits you and let the control do its job; there is no point turning the setting all the way up to heat faster. Keep the front of the control clear and clean. If several rooms have the same model, consistent setpoints from one room to the next limit the exchange of cold and warm air between zones. After a power outage, simply check the display when the power comes back and adjust if needed.
An installation designed for your home
We do not sell a thermostat the way you sell a box off a shelf. Every AirGreen recommendation starts from your actual installation: type of unit, voltage, number of conductors, location of the box and your family's habits. As a Montréal family HVAC business active for more than 15 years and holding an RBQ licence, we serve Montréal, Laval, Longueuil, the North Shore and the South Shore. Our technicians come with the tools needed to check the circuit, install the control level, run operating tests and show you the settings that matter. You are left with a clean installation and a thermostat you know how to use. To see the products up close, our showroom in Boucherville is open to you.
To order this thermostat and have it installed correctly the first time, contact AirGreen. Our team serves Montréal, Laval, Longueuil, the North Shore and the South Shore, and every installation ends with complete tests and a short demonstration of the settings.
Key facts: HONEYWELL TH401/U
Four things to know, then its ID card in twelve answers. “—” means the manufacturer does not publish it.
Is the HONEYWELL TH401/U compatible with your heating?
Two steps, thirty seconds. The verdict takes your system and your wiring into account.
Full compatibility table
A thermostat that works on 120/240 V
Tap an element to see what it does. A working diagram, not a substitute for the manufacturer’s installation guide.
Try the HONEYWELL TH401/U before you buy
Raise the setpoint, change the mode: see how it responds.
Winter, Rate Flex D and rebates: what this thermostat changes
With Hydro-Québec’s Rate Flex D, electricity costs less most of the winter and more during a few peak hours. Turning the setpoint down a few degrees during those hours is what counts.
What each room costs
An interactive drawing of what this kind of control does day to day.
The HONEYWELL TH401/U or its closest sibling?
The most useful comparison: the model right next to it in our catalogue.
The right thermostat in three questions
If this model is not the right one for you, the page says so and shows you which one is.
Products that go with the HONEYWELL TH401/U
Parts named in its spec sheet that we sell and install.
Installed and set up by our technicians, in five steps
What we do at your place, in order. The on-site estimate is free.
- 01LoadWe add up the heaters on the circuit and check the thermostat’s range.
- 02Shut-offBreaker shut off at the panel, 2- or 4-wire circuit identified.
- 03MountingWiring, mounting, power back on.
- 04TestHeating checked room by room.
- 05SettingsSchedule, connection and app if the model has them.
HONEYWELL TH401/U specifications
From the manufacturer’s sheet. Type a word: the list filters as you write.
No line matches. Try another word.
Frequently asked questions about the HONEYWELL TH401/U
Short answers, no detours.
What does the HONEYWELL TH401/U work with?
According to the manufacturer’s sheet: electric baseboards, radiant ceilings, convectors, forced-air units.
What load can it control?
Up to 2,500 W at 240 V (1,250 W at 120 V), per the manufacturer’s sheet.
Who installs it?
Our technicians: the circuit is shut off at the panel, the heater load is checked, then the thermostat is wired and tested.
Can it be controlled remotely?
Not directly: it has no built-in Wi-Fi.
What is the warranty?
3 years, per the manufacturer’s information.
Does AirGreen install it?
Yes. We sell and install this product in Montréal, Laval, Longueuil, the South Shore and the North Shore. The on-site estimate is free.
No question matches. Call us at 514 316-2973.
Your thermostat, installed and set up by our technicians
We check your system and wiring, install the thermostat, connect it and program it with you. One visit, one installed price.