Réparation d’une thermopompe murale Fellini à Ville Mont-Royal
Reading time: 3'

Repair of a Fellini wall-mounted heat pump in Ville Mont-Royal

Technical intervention in an underground parking lot

At AirGreen , we are often called upon to intervene in unique situations—and this repair of a Fellini wall-mounted heat pump in Town of Mount Royal is a perfect example. The client, the owner of a modern condominium, contacted us after noticing that their HVAC system was no longer producing heat in heating mode , despite the normal operating noise of the outdoor unit installed in the building's underground garage .

Initial analysis and intervention constraints

Indoor parking facilities present specific challenges:

  • Restricted ventilation , which can affect the heat transfer of the condenser.

  • Excessive condensation in winter.

  • Accumulation of fine dust from concrete and vehicles.

Upon our arrival, our technician carried out a series of preliminary checks:

  • correct supply voltage (240 V);

  • no error on the electronic card;

  • operational outdoor fan;

  • absence of frost or physical blockage.

However, the blowing temperature measured inside did not exceed 16°C , indicating a lack of compressor power .

In-depth diagnosis: refrigerant leak and compressor overheating

We connected our digital pressure gauges to analyze the pressures. The result: abnormally low low pressure and unstable high pressure , typical of a partial leak of R410A refrigerant .
A closer inspection revealed a micro-leak at the service connection of the Fellini condenser, aggravated by the constant vibrations caused by the metal suspension of the ceiling support.

Steps of repair

Our team undertook a complete and certified intervention :

  1. Draining and recovery of residual refrigerant in accordance with environmental standards.

  2. Repair of the defective connection by brazing and reinforcement of the weld.

  3. Cleaning the circuit with nitrogen gas to remove all traces of humidity.

  4. Extended leak test at 300 psi for 45 minutes to validate the correction.

  5. Complete system recharge with the refrigerant recommended by Fellini.

Each step was carried out with calibrated tools and cross-checks to ensure the sustainability of the intervention.

Results after repair

Once the system was restarted, the results were immediate:

  • Balanced and stable pressures ;

  • Indoor blowing temperature measured at 8.2°C in air conditioning mode (and 45°C in heating mode);

  • Quiet and smooth compressor operation ;

  • no excessive vibration on the suspended support.

The customer has thus regained optimal thermal comfort , and his Fellini heat pump now operates at full efficiency without loss of performance.

Maintenance tips for garage-installed systems

To extend the life of a similar installation, we recommend:

  • to have the anti-vibration mounts inspected at least once a year;

  • to clean the outdoor coil to prevent the accumulation of dust and concrete deposits;

  • to perform a preventive leak test before each heating season;

  • and check the ventilation of the room to ensure good heat exchange.